dbx 160-161 Calibration Procedure 电路图.pdf
《dbx 160-161 Calibration Procedure 电路图.pdf》由会员分享,可在线阅读,更多相关《dbx 160-161 Calibration Procedure 电路图.pdf(21页珍藏版)》请在收音机爱好者资料库上搜索。
1、ISITIAL FACTORY TEST 6 ALIGN?!ENT PROCEDL7RE DBX MODELS lb0 AND 161 WITHOUT Ii47 & R39 (LATE 160 & 161) TEST EQUIWENT REQUIRED: QU_41T l7-YITEM 1Signal Oscillator 1Digital Multimeter 1Oscilloscope 1 . Wide Range db Deter 1Harmonic distortion meter 1 1 + 3 db meter (cal_ref. 1 volt) (optional) Resist
2、or Substitution Box TYPE OR EQUIVALENT Kron-Hite 4200, Heath 1272 Dana 3300, B & K 282, Digitec 2110 Any (covering audio band) DBX SK-C-1026, HP 427 DBX SK-B-1070, Heath lM58, HP330, GR1500, CR1900 DBX SKC-1071 Any.k w 57. values, typically 10K to 470K NOTE:On model 160, tie It - IIterminals to Gnd,
3、for normal testing. Revised 4-70-77 350325-03 RadioFans.CN 收音机爱 好者资料库 DBX MODELS 160 - 161 INITIAL TEST OUTLINE SEQUENCE OF STEPS: 1) Supply Trim 2) RMS Trim 3) VCA & RMS Symmetry 4) Level Calibration 5) Threshold Calibration 6) Gain Change & input zero calibration 7) Output Calibration 8) Input Tra
4、cking g) Compression Circuit Calibration 10) (R78) Correct Value Test 11) Clipping 12) Response 13) Signal Clamping (Model 160 only) 14) Noise 15) Seal Pots 16) Burn-in . 350025-03 RadioFans.CN 收音机爱 好者资料库 P-3 . 160/161 INITIAL PROCEDURE Before applying power to unit,check mechanical zero of meter. 1
5、) 2) 274) 3) 4) 5) Supply Trim: Put resistance substitution box across R14 and measure DC voltage at (+) side of C7.Turn sub box until voltage is +15 volts + 50 MV (+14.950 to + 15.050). place. Solder appropriate resistor in Check (-) side of C8 to verify that it is -15 volts + 200 MV - (-14.800 to
6、-15.200) RMS Trim: (205) Connect sub box across the two RMS trim pins, and measure the offset at the input pin of the RMS module.Trim the sub box until voltage is zero + 15 MV,and solder appropriate resistor in place. - (209) With input of 1.228 VRMS at 100 Hz,place sub box between + v and the trim
7、pin on the RMS module.Drop input level to - 60 db and adjust sub box until a symmetrical waveform is observed on camp pin, insert value chosen in R36 spot (typ 8K to 75KR) VCA & RMS Symmetry: Set oscillator to 1.228 VRMS a) 100 Hz (Tune for peak on distortion meter) Set front panel compression knob
8、to3 and output gain to +20.Turn threshold control counter clockwise from3 until external db meter reads 0 db.Turn trim pots R27 and R34 until distortion reads minimum. Level Calibration: Set oscillator to 1.228 VRMS a) 100Hz turn R63 until the voltage at the end of R79 (closest to the center of unit
9、) is -.Oll VDC Threshold Calibration: Turn front panelThreshold Control until both leds are off.Loosen knob and position so that pointer indicates just past 1V and retighten. (When both leds are off the input signal is at threshold level.) (See fig. 1.)Step the oscillator up and down in 10 db steps