1、1RMX0005 Title:RMX 2450 AC Wire Replacement Bulletin #:RMX0005Issue Date:December 13, 2000 Models Affected:RMX 2450Bulletin Revision:A Production Range: 01/200010/2000 (serial # 0100 xxxxx1000 xxxxx) Service Bulletin Description In the RMX 2450, the wiring to the AC switch is routed at the factory a
2、long the side of the chassis and secured with tie wraps to small loops (called bridge lances) in the chassis. One bridge lance lies right next to the toroidal power transformer with only a few millimeters to spare. In shipping or handling the amplifier, the potential exists for the transformer to sh
3、ift and/or the chassis to flex, causing the transformer to pinch or abrade the wires against the bridge lance, and possibly cause it to cut through the insulation on the wire. This could short-circuit the AC current to the chassis, a very dangerous situation. Bulletin RMX0004 described a procedure r
4、erouting the AC wiring so it is not susceptible to being pinched and shorted to the chassis. This bulletin is a companion to bulletin RMX0004 and describes the procedure for replacing AC wires that have been damaged by being pinched or crushed between the power transformer and the bridge lance. This
5、 wire replacement procedure is meant to be performed only in conjunction with the modification described in bulletin RMX0004. NOTE: This procedure is a conditional part of a mandatory modification that corrects a potentially dangerous situation in all RMX 2450 amplifiers built in the affected produc
6、tion range. NOTE: Repair to the AC primary wires as described in this bulletin must be performed at an authorized service center or the factory. Units affected The units affected are RMX 2450 amplifiers manufactured from January through October 2000. AC wire inspection Step 5 of bulletin RMX0004 ins
7、tructs you to inspect the two brown AC wires for possible damage from being pinched or crushed between the power transformer and the bridge lance. Examine the wires where they were tied to the bridge lance. Flex the wires to expose any possible deep cuts in the insulation or hidden wire breaks. See
8、Figures 1 and 2. Either of these conditions mandates the replacement of a damaged wire: A break in the insulation exposes any of the wires strands. Any wire strands appear to be broken, whether visible or not. Instructions Parts required (order as needed from QSC Technical Services): 25” UL- listed
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Qsc Rmx0005 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf