Purplemc76 Limiter 电路图.pdf
《Purplemc76 Limiter 电路图.pdf》由会员分享,可在线阅读,更多相关《Purplemc76 Limiter 电路图.pdf(18页珍藏版)》请在收音机爱好者资料库上搜索。
1、Purple Audio Inc. MC76 Peak Limiter Effective with serial number 001 The MC76 is a Monaural FET Peak Limiting Amplifier RadioFans.CN 收音机爱 好者资料库 Units of this type have been in wide use for many years to provide precise and automatic control of peak signal levels in recording studios, disc mastering
2、facilities, broadcast stations and sound reinforcement applications. Operation of the MC76 Limiting Amplifier should be very familiar to those who have used similar devices in the past. UNITS FEATURE: *Discrete Transistor Electronics *Transformer Balanced XLR Inputs and Outputs *Zener Shunt Regulate
3、d Power Supply *Single Element Class A Output Amplifier *Compression Ratios 4:1, 8:1, 12:1 and 20:1 *Fast Attack Time 20 microseconds to 800 microseconds *Release Time 50 milliseconds to 1.1 second *Gain 45dB (full gain with no limiting) *VU Meter for output level and gain reduction indication *Buil
4、t In Stereo Interconnect with offset adjustment *Heavy Gauge Stainless Steel Enclosure *Purple Anodized Aluminium Front Panel *120/240 volt operation *3 Year Warranty UNPACKING AND INSTALLATION Your MC76 was packed with care at the factory. The packaging was designed to protect the unit from rough h
5、andling. However, once the unit leaves us, it may pass through the hands of those who have no idea what is in the box, may not be happy with work, may like to throw things, dont care. etc. Despite the heavy duty carton and foam blocks the unit was packed with, we recommend you inspect the box and it
6、s contents immediately for any sign of damage that may have occurred in transit. If there is damage, you should save all the packing materials and contact your vendor and shipper immediately. We recommend you keep the packing materials. Murphys law states that once you throw away the box the likelih
7、ood you will need it back will increase in proportion to the square of the distance from your service center multiplied by the cost of replacement packing materials. RadioFans.CN 收音机爱 好者资料库 The carton we ship out contains: *One MC76 Limiting Amplifier *This Manual *One six foot (two meters) IEC Cabl
8、e *Warranty Card The unit can operate safely and within specification over a range of ambient temperatures from 0 C (+32 F) to +50 C (+122 F). Humidity is generally not a factor unless there is condensation. One way to avoid condensation is to keep the ambient temperature reasonably constant. The un
9、it can be powered from either 100-125 volt or 200-250 volt AC Mains at a line frequency of 50 or 60 Hz. The operating voltage should be set BEFORE you plug the unit in. The power inlet module integrates the voltage selector into the fuse holder. The selected voltage (115V or 230V) will show through
10、a small window in the flip down “door” that covers the fuse holder. The unit should be supplied with an IEC cable applicable to your locality. The fuses and voltage selection should be set up for you, BUT NEVER ASSUME! Fuses: At 115 Volts the unit should be fused for 1/8 Amps At 230 Volts the unit s
11、hould be fused for 1/16 Amps Signal Connections are made via standard XLR connectors. XLR Pin Assignments: PIN 1 = Chassis, Earth, Ground PIN 2 = Signal Hot, Positive, + PIN 3 = Signal Cold, Negative, - Wiring systems vary from facility to facility. PIN 1 may or may not be used to terminate a shield
12、 or drain wire. In general this pin and the shield or drain wires connected to it are not to be used to “Ground” or “Earth” the unit. Shields and Drain Wires should NOT carry current and are generally connected at only one end of any given wire. For your convenience and to assure that the chassis ca
13、n be easily grounded (earthed) there is a Chassis Ground Lug on the back of the unit and the center pin of the IEC power inlet is connected to the chassis as well. UNPACKING AND INSTALLATION - continued PINS 2&3 of the input and output XLR connectors must be connected to get signal in and out of the
14、 unit. Since the inputs and outputs are transformer balanced there is no problem unbalancing either the input or output or both. Because the input attenuator is ahead of the input transformer taking PIN 3 of the input XLR to signal common is the preferred way to unbalance the input. To maintain cons
15、istent phase from input to output connection of PIN 3 to audio common is the preferred way to unbalance the output unless you WANT to flip the phase. BRIEF OPERATING INSTRUCTIONS Once the unit is set to the correct line voltage, plugged in and audio connected. 1) Set Input and Output Gain controls s
16、traight up to 12 Oclock. Do the same for Attack and Release controls. 2) Pick a Ratio - a good place to start is 12:1 but any of the four available will do - higher ratios will give a harder limiting effect while lower ratios will provide a softer compression effect. 3) Set the meter select to GR or
17、 Gain Reduction. 4) Run the program material of your choice through the MC76. 5) Observe the amount of Gain Reduction on the meter. Adjust Input Gain and observe how GR indication changes and listen to how the program material sounds. 6) Select Meter to +4 (or +8 if 0VU in your facility is reference
18、d to +8dBu) and look at the level coming out of the MC76. Set the Output Gain to a level that makes sense for you and then return the Meter Select to GR after you set the output level. 7) Experiment Note 1: Attack and Release times are quicker with clockwise rotation of controls. If you set the rele
19、ase too quick the bass frequencies can modulate gain limiting at an audio rate. This may not sound good on intruments like a bass guitar. Fast release does sound good in many applications such as where bass frequencies are not a major component. Note 2: If you turn the Attack control counter-clockwi
20、se until it clicks, this will disable the limiter leaving only the gain which can be substantial. (Be mindful of your speakers!) Note 3: You CAN push more than one Ratio button at a time. Note 4: The XLR connectors are wired Pin 2 hot. Note 5: The VU meter should be left in GR mode during normal ope
21、ration as it is unbuffered and will add distortion to the signal if left hanging across the output. OPERATING INSTRUCTIONS The Attack Time of the MC76 is the time it takes for the detector circuitry and FET to respond to a signal as it exceeds the threshold. This parameter is variable by the user si
22、nce the adjustment may have a significant effect on the sound of the program material. The Release Time may be defined as the time it takes the limiter to return to its normal gain, after the signal which has caused the gain reduction has dropped below the threshold. The release time is variable for
23、 the same reason that Attack time is and can substantially alter the sound of the program material passing through the MC76. Together, Attack and Release times will define much of the sound or coloration in any given application. METER ZERO ADJUST (Allow 15 minutes warm-up) Push the GR meter functio
24、n switch. The VU meter should read 0 on the VU scale since the limiting function is disabled (the attack control knob is turned to OFF). If the 0 indication has drifted beyond + or - 1 dB, it should be adjusted. This may be done through the hole in the front panel located between the Input and Outpu