1、Table of Contents Loudspeaker Users Manual Introduction2 Unpacking2 Connecting to an Amplifier2 Selecting a Power Amplifier2 Limiter Calibration2 Using the UMH Points3 U-Bracket and Speaker Mounting Hardware4 Complex Conic Horn Orientation4 Loudspeakers with Transformers Installed4 Additional Inform
2、ation4 Loudspeaker Users Manual 4 Figure 1 shows a sectional view of a UMH attachment bracket. While the UMH brackets are glued in at the factory, we still recommend that you remove adjacent bolts one at a time so that there is no danger of pushing the bracket into the cabinet accidently. Renkus-Hei
3、nz recommends the following maximum working loads per loudspeaker cabinet when using Renkus-Heinz supplied eye bolts: 1/4-20 or M6 thread - 270lbs/122kg, 3/8-16 or M10 thread - 450lbs/204kg. You should use a mini- mum of two of the UMH points to suspend any Renkus-Heinz loudspeaker. Always use threa
4、d locking compound for any eye bolts or other fasteners used to suspend loudspeakers. U-BRACKET AND LOUDSPEAKER MOUNTING HARDWARE If you ordered your loudspeaker with optional u-bracket or speaker mounting hardware, your loudspeaker will ship with flat head bolts installed in the attachment points.
5、These flat head bolts are installed as place holders and are not intended for use with the brackets. Use the bolts that come with the u-bracket assembly to attach the loudspeaker. See the instruc- tion sheet enclosed with the brackets for details. If your loudspeaker was shipped with a compatible nu
6、t plate for use with the OmniMount or Allen Products MultiMount, you can use the bolts installed in the nut plate to attach the loudspeaker to the mount. COMPLEX CONIC HORN ORIENTATION Most of Renkus-Heinzs Complex Conic horns are physically symmetrical and designed to allow rotation within the encl
7、osure. Figure 2 shows the Complex Conic horn orientation. For wide horizontal dispersion, the dif- fraction slot in the throat should be vertical. Our unique TRue Array Principle design requires that Complex Conic horns be oriented with the narrow angle of coverage horizontal. When you order a Refer
8、ence Point Array, we ship the loudspeakers with the horns in this orientation (diffraction slot horizontal). If you ordered single loudspeakers, the horns will be installed for conventional cabinet verti- cal/horn horizontal installation. If you wish to use a “tight-packed” array, or install the enc
9、losures in a horizontal position while maintaining wide horizontal coverage, you can easily rotate the horns. Rotating a Complex Conic horn is easy. First remove the grill. Then remove the eight flat head bolts securing the horn to the cabinet. Gently pull the horn out of the cabinet just enough to
10、clear the cut-out, rotate the horn 90 degrees and replace it in the cutout. Finally, reinstall the bolts and the grill. LOUDSPEAKERS WITH TRANSFORMERS INSTALLED Renkus-Heinz loudspeakers are available with transformers installed for use with 70.7Vand 100Vconstant voltage sys- tems. The power rating
11、on the model number plate will list the wattage tap and voltage for the factory installed trans- former. ADDITIONAL INFORMATION Renkus-Heinz is dedicated to working with you to solve sound reinforcement problems, whenever and wherever they arise. If you have any questions not answered by this manual
12、, please contact the factory at the numbers or addresses below. Wide Angle of Coverage Complex Conic Horn Orientation FIGURE 2 19201 Cook St. Foothill Ranch, CA 92610 Phone: +1-949-588-9997 Fax: +1-949-588-9514 e-mail: salesrenkus- RH508 14/02 RadioFans.CN 收音机爱 好者资料库 INTRODUCTION Congratulations on
13、your purchase of a Renkus-Heinz loudspeaker. This manual will help you install and use your Renkus-Heinz loudspeaker properly, so that it delivers years of trouble-free operation and superior performance, as it was designed to. UNPACKING four- or eight-pole Neutrik SpeakOn con- nectors, terminal bar
14、rier strip, or rubber-jacketed wire pig-tail. The model/serial number label lists the connections for proper hook-up. We use the same numbering conventions for SpeakOn and terminal strip connectors: See Table 1 for proper wiring instructions. Pig-tail connections are color coded: the proper wiring i
15、s shown on the model number plate. Always use crimp-on terminals with the terminal strip connections do not connect bare wire. Its possible that your speaker was specially ordered with a different type of connector, so always be sure to check the model number plate on your loudspeaker and follow the
16、 wiring diagram and instructions it displays. SELECTING A POWER AMPLIFIER Renkus-Heinz loudspeakers have three power specifications: RMS, Program and Peak. The RMS rating is an AES/EBU rating, the Program rating is 3dB higher than the RMS and the Peak rating is 6dB higher than RMS. The Program ratin
17、g is printed on the model number sticker on the back of the loudspeaker. When selecting a power amplifier for your loudspeaker you should consider the needs of your specific application. To provide the full output capability of your loudspeaker, you should choose an amplifier whose RMS output rating
18、 falls between the RMS and Program ratings of the loudspeaker. This means the amplifiers peak output may exceed the capacity of the loudspeaker. Factory-calibrated Loudspeaker Specific Processing in a Renkus-Heinz rack-mount controller or in a Renkus-Heinz amplifiers plug-in card will always deliver
19、 the most reliable protection for your loudspeaker along with the best possible sound. LIMITER CALIBRATION You can use other signal processors with Renkus-Heinz loudspeakers, but in order to protect them from damage, you must do your best to re-create the process Renkus-Heinz Engineering uses to set
20、 up the limiters. The following procedure is as close as you can get without access to the specialized equipment we use at the factory. Loudspeaker Users Manual 2 1+, 1-2+, 2-3+, 3-4+, 4- Fully PassiveFull RangeNot Used Bi-Amp, Two-wayLowHigh Bi-Amp, Three-wayLowMid/High Tri-amp, Three-wayLowLow*Mid
21、High SubwooferWoofer 1Woofer 2 * Passive Mid-HighMid/HighMid/High * Active Mid-HighMid *High *Mid *High * * Speakon NL8 connection (Touring Products) Notes: Standard connections shown, check model plate for your specific connection * When woofers wired separately * Terminal strip or Speakon NL4 conn
22、ection Terminal or Speakon connection Speaker Type TABLE 1 Loudspeaker Users Manual 3 You will need a sine wave generator (or a test CD with sine waves of various frequencies) and a volt meter. 1) Set up your systems gain structure. 2) Disconnect the loudspeakers from the amplifier. Do not set the l
23、imiters with the loudspeakers connected you will damage the loudspeakers. This damage is not covered by our warranty! 3) Feed a sine wave signal into the amplifier. Use a frequency in the lower part of the drivers pass band: 60 Hz for sub- woofers, 200 Hz for lows and fully passive speakers, 1 kHz f
24、or mid-ranges or mid-highs and 2.5 kHz for compression drivers. 4) Connect the volt meter to the amplifier outputs. 5) Check Table 2 for the maximum RMS voltage that should reach the loudspeaker based on its Program power rating. Raise the level of the signal generator until the volt meter reads two
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Renkus-Heinz Loudspeaker User's Manual 2 电路图 Renkus Heinz User
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
PHILIPS 1&1BIS 电路原理图.jpg
PHILIPS 103A 电路原理图.gif