1、SERVICE MANUAL Model: DVR4015VSS DVD PLAYER www.akai.ru RadioFans.CN 收音机爱 好者资料库 目录 Safety information -3 1 General guid-3 2 Low zeta potential leaking inspection -3 3 High zeta potential leaking inspection -3 Device avoiding ES(Electric Susceptible) Influence of ESD (Electric Susceptible Discharge)-
2、3 Technical specification -4 Mechanical diagram - -8 Mechanical Parts- 9 Packing and accessories -10 Disassemble and assemble-11 1 Take out disc from trouble player -11 2 PCB position -11 Disassemble and assemble parts of the unit -12 1 Can open the tray by electricity -12 2 Can not open the tray by
3、 electricity -12 3 Assemble the unit -12 Attachment 1- 13 Block Diagram/Electric circuit diagram 1 Block diagram -14 2 Electric circuit diagram -15 3 Decoder board diagram -16 4 AV output board diagram -20 5 Control board diagram -23 Attachment 2-24 PCB Diagram 1 Upper decode board PCB diagram -25 2
4、 Lower decoder board PCB diagram -26 3 AV output board PCB diagram -27 4 Control board PCB diagram -30 Attachment 3-32 Component list 1 AV output board component list -33 2 Decoder board component list -36 3 Control board component list -39 RadioFans.CN 收音机爱 好者资料库 SAFETY INFORMATION General guide Ge
5、neral guide 1.Observe the original circuit during maintenance. if short circuit occurs, change the over-hot or damaged components. 2.Observe all the protective device after maintenance, such as whether the shielding cover or paper is assembled well. 3.To avoid electric shock, please inspect electric
6、ity leakage after maintenance Low zeta potential leaking inspection 1.Take out AC cord and connect a piece of wire between two legs of the outlet. 2.Use Gear R x 10K of the voltmeter to measure the spares on AC outlet and exposed metallic part with short circuit. The resistance between screw cap, co
7、ntrol shaft should be unlimited. uF AC voltage table to have discover metal accessory of equipment creepage checking circuit cold water canal(earthing) picture 1 High zeta potential leakage inspectionHigh zeta potential leakage inspection .As illustrated 1, Connect Resistor with 1.5K, 10W and capaci
8、tor 0.15 between exposed metallic part and device of fine connection to the earth (water pipe etc.). 2.Plug-in AC cord directly to AC outlet. Do not inspect with shield adaptor. 3.Utilize 1000 or more sensitive voltmeter to measure alternating voltage. 4.Turn back the AC plug-in from AC outlet then
9、iterate the inspection as above. 5.Inspect the voltage of the resistor between other exposed metallic parts and the earth with the same way. 6. The voltage must not be over than 0.75Vrms at any points on the resistor. Electric leakage should not be over 0.5mA when processing high voltage leakage tes
10、ting through Device avoiding ES(Electric Susceptible) 8. When disassembling and replacing the ES device, try to reduce body movement (Or, the movement of legs, the friction of fibrous of clothes, or elevating the legs from the floor will generate static electricity ESD, causing damage to the ES devi
11、ce.). Influence of ESD (Electric Susceptible Discharge exceeded the restrained figure, electric shock should be possibly suffered. Do maintain the unit and inspect once more before return to the user. Device avoiding ES influence of ESD. Some solid semi-conductor devices are easy to be damaged by st
12、atic electricity. These devices are generally called ES device. The typical devices are IC, field effect component and semi-conductor laser diode. The following technology helps to abate the danger of ESD on body before handle any semi-conductor or semi-conductor component. Or wear the ESD bangle av
13、ailed from the market to eliminate the threaten of static electricity on human body. 2.Put the electronic parts with ES device on the surface of conductor such as aluminium foil after take them out in order to protect static electricity from accumulation and explosion. 3.Solder or disassemble ES dev
14、ice through iron connecting the earth. 4. Utilize device only anti-static electricity to disassemble soldering tin. Non-anti static electricity device (ESC protection) will release ES that damage ES device. 5.Do not use chemical volatile releasing static electricity that leads to damage ES device 6.
15、 Unless preparation for pre-assembling has been made, do not take out the ES device to be changed from the protective packing ( most of the changed ES devices are packed together with anti-static electrical foam or similar electric material, besides, countermeasures for down-lead short circuit are t
16、aken.). 7. Protective material should connect the model or the circuit component to be assembled in it before taking out the protective material from the ES device. Note: do not bear electricity to the model or the circuit, and pay attention to all the other safety information. 1 RadioFans.CN 收音机爱 好
17、者资料库 Technical specification DVD Electric gudideline 1:Video parts NO. Test items Test point Performance request Units Remake 1 video 1.00.2 Vp-p Y 0.70.14 Vp-p chroma 0.880.176 Vp-p 2 S-vid eo C Color sync 0.30.06 Vp-p 3 Y.Cr. Cb/Y.Pr.Pb 0.7+/-0.14 Vp-p 4 Output range R.G.B 0.7+/-0.14 Vp-p 5 Level
18、definition 450 lines 6 bandwidth(+3/-6 dB) 5.5 MHz 100KHz 0 dB 7 differential coefficient bit DP 2 degree 75 loads 8 Lum non distortion 5 % 75 loads 9 Differential plus DG 2 % 75 loads 10 Y 56 (except power) dB 75 loads U channel 50 dB 75 loads 11 C V channel 50 dB 75 loads R channel 50 dB 75 loads
19、G channel 50 dB 75 loads 12 S/N ratio R G B B channel 50 dB 75 loads 2:Audio(Test signals:TCD-784) 2:Audio(Test signals:TCD-784) NO. Test items Test point Performance request Units Remark 1 Lines audio input, output levels 1.8+0.2/-0.8 Vrms DVD(LPCM)、CD Audio input impedance:10K 2 Breadth rage respo
20、nse 1.5 dB DVD(LPCM) 20Hz20KHz 3 S/N 80 dB A count power 4 THD 10 % 1KHz A count power 10W 5 Condition areas 90 dB 1KHz A count power 6 Separate degree 70 dB 1KHz A count power 7 Channel inbalance 1.0 dB DVD(LPCM)、CD 8 Coaxial output range 0.520% Vp-p 75 1% loads 9 Optical output wavelengh (p) 66030
21、 nm 3:Other characteristic parts 3:Other characteristic parts NO. Test items Test point Capability request Units Remark 1 Load time 10 S 2 Remote control for instance 5 m Front surface15areas 3 Input power voltage 230V10% 50Hz 4 Expend power 110W Normal works 5 Deposited condition of temperature -25
22、+55 C 6 Works condition of temperature 0+40 C 7 Freedom lower Accord GB/T 2423.8-1995 request 8 Disc formats (1)DVD: 12cm single side, single layer;12cm single face, double layer;12cm double face. Double layer; 8cm single face, single layer; 8cm single face, double layer;8cm double face, double laye
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Akai-DVR-4015-VSS-Service-Manual1 电路图 维修手册 Akai DVR 4015 VSS Service Manual 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
索尼SONY WM-F2078电路原理图.zip