Hitachi-DVP-305-U-Service-Manual 电路图 维修手册.pdf
《Hitachi-DVP-305-U-Service-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Hitachi-DVP-305-U-Service-Manual 电路图 维修手册.pdf(106页珍藏版)》请在收音机爱好者资料库上搜索。
1、TK No.9003E SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT DVD PLAYER SERVICE MANUAL 2000MarchDigital Media Products Division, Tokai DV-P305U DV-P303U 1. Precautions 2. Reference Information 3. Product Specification 4. Operating Instructions 5. Disassembly and Reassembly 6. Circuit D
2、escriptions 7. Troubleshooting 8. Exploded Views 9. Replacement Parts List 10. Block Diagram 11. PCB Diagrams 12. Wiring Diagram 13. Schematic Diagrams CONTENTS RadioFans.CN 收音机爱 好者资料库 1-1 1. Precautions 1-1 Safety Precautions 1) Before returning an instrument to the customer, always make a safety c
3、heck of the entire instrument, including, but not limited to, the following items: (1) Be sure that no built-in protective devices are defective or have been defeated during servicing. (1)Protective shields are provided to protect both the technician and the customer. Correctly replace all missing p
4、rotective shields, including any remove for servicing convenience. (2)When reinstalling the chassis and/or other as- sembly in the cabinet, be sure to put back in place all protective devices, including, but not limited to, nonmetallic control knobs, insulating fish papers, adjustment and compartmen
5、t covers/shields, and isolation resistor/capacitor networks. Do not operate this instrument or permit it to be operated without all protective devices correctly installed and functioning. (2) Be sure that there are no cabinet openings through which adults or children might be able to insert their fi
6、ngers and contact a hazardous voltage. Such openings include, but are not limited to, excessively wide cabinet ventilation slots, and an improperly fitted and/or incorrectly secured cabinet back cover. (3) Leakage Current Hot Check-With the instrument completely reassembled, plug the AC line cord di
7、rectly into a 120V AC outlet. (Do not use a isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standards institute (ANSI) C101.1 Leakage Current for Appliances and Underwriters Laboratories (UL) 1270 (40.7). With the instru
8、ments AC switch first in the ON position and then in the OFF position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed metal parts of the instrument (antennas, handle brackets, metal cabinets, screwheads, metallic overlays, control shafts, etc.), especially any exp
9、osed metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5mA. Reverse the instrument power cord plug in the outlet and repeat the test. See Fig. 1-1. Any measurements not within the limits specified herein indicate a potential shock hazard that mus
10、t be eliminated before returning the instrument to the customer. Fig. 1-1 AC Leakage Test (4) Insulation Resistance Test Cold Check-(1) Unplug the power supply cord and connect a jumper wire between the two prongs of the plug. (2) Turn on the power switch of the instrument. (3) Measure the resistanc
11、e with an ohmmeter between the jumpered AC plug and all exposed metallic cabinet parts on the instrument, such as screwheads, antenna, control shafts, handle brackets, etc. When an exposed metallic part has a return path to the chassis, the reading should be between 1 and 5.2 megohm. When there is n
12、o return path to the chassis, the reading must be infinite. If the reading is not within the limits specified, there is the possibility of a shock hazard, and the instrument must be re-pared and rechecked before it is returned to the customer. See Fig. 1-2. Fig. 1-2 Insulation Resistance Test DEVICE
13、 UNDER TEST (READING SHOULD NOT BE ABOVE 0.5mA) LEAKAGE CURRENT TESTER EARTH GROUND TEST ALL EXPOSED METER SURFACES ALSO TEST WITH PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED) 2-WIRE CORD Antenna Terminal Exposed Melal Part ohm ohmmeter RadioFans.CN 收音机爱 好者资料库 Precautions 1-2 2) Read and comply
14、 with all caution and safety re- lated notes non or inside the cabinet, or on the chassis. 3) Design Alteration Warning-Do not alter of add to the mechanical or electrical design of this instrument. Design alterations and additions, including but not limited to, circuit modifications and the additio
15、n of items such as auxiliary audio output connections, might alter the safety characteristics of this instrument and create a hazard to the user. Any design alterations or additions will make you, the service, responsible for personal injury or property damage resulting therefrom. 4) Observe origina
16、l lead dress. Take extra care to assure correct lead dress in the following areas: (1) near sharp edges, (2) near thermally hot parts (be sure that leads and components do not touch thermally hot parts), (3) the AC supply, (4) high voltage, and (5) antenna wiring. Always inspect in all areas for pin
17、ched, out-of-place, or frayed wiring, Do not change spacing between a component and the printed-circuit board. Check the AC power cord for damage. 5) Components, parts, and/or wiring that appear to have overheated or that are otherwise damaged should be replaced with components, parts and/ or wiring
18、 that meet original specifications. Additionally, determine the cause of overheating and/or damage and, if necessary, take corrective action to remove any potential safety hazard. 6) Product Safety Notice-Some electrical and mechanical parts have special safety-related characteristics which are ofte
19、n not evident from visual inspection, nor can the protection they give necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts that have special safety characteristics are identified by shading, an ( )or a ( )on schematics and parts lists. Use of a sub
20、stitute replacement that does not have the same safety characteristics as the recommended replacement part might created shock, fire and/or other hazards. Product safety is under review continuously and new instructions are issued whenever appropriate. RadioFans.CN 收音机爱 好者资料库 Precautions 1-3 1-2 Ser
21、vicing Precautions CAUTION : Before servicing Instruments covered by this service manual and its supplements, read and follow the Safety Precautions section of this manual. Note : If unforseen circument create conflict between the following servicing precautions and any of the safety precautions, al
22、ways follow the safety precautions. Remember: Safety First. 1-2-1 General Servicing Precautions (1) a. Always unplug the instruments AC power cord from the AC power source before (1) re-moving or reinstalling any component, circuit board, module or any other instrument assembly, (2) disconnecting an
23、y instrument electrical plug or other electrical connection, (3) connecting a test substitute in parallel with an electrolytic capacitor in the instrument. b. Do not defeat any plug/socket B+ voltage interlocks with which instruments covered by this service manual might be equipped. c. Do not apply
24、AC power to this instrument and /or any of its electrical assemblies unless all solid-state device heat sinks are correctly in- stalled. d. Always connect a test instruments ground lead to the instrument chassis ground before connecting the test instrument positive lead. Always remove the test instr