1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MA178 2005/2 CD RECEIVER MA17820052 KD-G414,KD-G413 TABLE OF CONTENTS 1PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPEC
2、IFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 4ADJ
3、USTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. 1-26 KD-G413KD-G414 CONTROL PANELBLACKSILVER Area suffix UI - India RadioFans.CN 收音机爱 好者资料库 1-2 (No.MA178) SPECIFICATION Design and specifications are subject to change without notice. Microsoft and Windows Media are either registered trademarks or trademarks of Microsoft Corporation in the United
5、 States and/ or other countries. AUDIO AMPLIFIER SECTION Maximum Power OutputFront50 W per channel Rear50 W per channel Continuous Power Output (RMS) Front19 W per channel into 4 , 40 Hz to 20 000 Hz at no more than 0.8% total harmonic distortion. Rear19 W per channel into 4 , 40 Hz to 20 000 Hz at
6、no more than 0.8% total harmonic distortion. Load Impedance4 (4 to 8 allowance) Tone Control RangeBass10 dB at 100 Hz Treble10 dB at 10 kHz Frequency Response40 Hz to 20 000 Hz Signal-to-Noise Ratio70 dB Line-Out Level/Impedance2.0 V/20 k load (full scale) Output Impedance1 k TUNER SECTION Frequency
7、 RangeFM87.5 MHz to 108.0 MHz AM531 kHz to 1 602 kHz FM TunerUsable Sensitivity11.3 dBf (1.0 V/75 ) 50 dB Quieting Sensitivity16.3 dBf (1.8 V/75 ) Alternate Channel Selectivity (400 kHz) 65 dB Frequency Response40 Hz to 15 000 Hz Stereo Separation35 dB Capture Ratio1.5 dB AM TunerSensitivity20 V Sel
8、ectivity35 dB CD PLAYER SECTION TypeCompact disc player Signal Detection SystemNon-contact optical pickup (semiconductor laser) Number of Channels2 channels (stereo) Frequency Response5 Hz to 20 000 Hz Dynamic Range96 dB Signal-to-Noise Ratio98 dB Wow and FlutterLess than measurable limit MP3 Decodi
9、ng FormatMPEG1/2 Audio Layer 3 Max. Bit Rate: 320 kbps WMA (Windows Media Audio) Decoding FormatMax. Bit Rate: 192 kbps GENERAL Power RequirementOperating VoltageDC 14.4 V (11 V to 16 V allowance) Grounding SystemNegative ground Allowable Operating Temperature0C to +40C Dimensions (W H D)Installatio
10、n Size (approx.)182 mm 52 mm 150 mm Panel Size (approx.)188 mm 58 mm 11 mm Mass (approx.)1.3 kg (excluding accessories) RadioFans.CN 收音机爱 好者资料库 (No.MA178)1-3 SECTION 1 PRECAUTIONS 1.1Safety Precautions ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attent
11、ion to such burrs in the case of preforming repair of this system. ! Please use enough caution not to see the beam directly or touch it in case of an adjustment or operation check. RadioFans.CN 收音机爱 好者资料库 1-4 (No.MA178) 1.2Preventing static electricity Electrostatic discharge (ESD), which occurs whe
12、n static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.2.1 Grounding to prevent damage by static electricity Static electricity in the work area can destroy the optic
13、al pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit
14、(optical pickup) on it. (2) Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. (3) Handling the optical pickup In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup a
15、re shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode. 1.3Handling the traverse unit (optical
16、pickup) (1) Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. (2) Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove
17、the anti-static pin when replacing the traverse unit. Be careful not to take too long a time when attaching it to the connector. (3) Handle the flexible cable carefully as it may break when subjected to strong force. (4) It is not possible to adjust the semi-fixed resistor that adjusts the laser pow
18、er. Do not turn it. 1.4Attention when traverse unit is decomposed *Please refer to Disassembly method in the text for the CD pickup unit. Apply solder to the short land before the flexible wire is disconnected from the connector on the CD pickup unit. (If the flexible wire is disconnected without ap
19、plying solder, the CD pickup may be destroyed by static electricity.) In the assembly, be sure to remove solder from the short land after connecting the flexible wire. 1M (caption) Anti-static wrist strap Conductive material (conductive sheet) or iron plate Pickup Short-circuit point (Soldering) Fle
20、xible wire (No.MA178)1-5 1.5Important for laser products 1.CLASS 1 LASER PRODUCT 2.DANGER : Invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam. 3.CAUTION : There are no serviceable parts inside the Laser Unit. Do not disassemble the Laser Unit. Repla
21、ce the complete Laser Unit if it malfunctions. 4.CAUTION : The CD,MD and DVD player uses invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the saf
22、ety switches. 5.CAUTION : If safety switches malfunction, the laser is able to function. 6.CAUTION : Use of controls, adjustments or performance of procedures other than those specified here in may result in hazardous radiation exposure. REPRODUCTION AND POSITION OF LABELS ! Please use enough cautio
23、n not to see the beam directly or touch it in case of an adjustment or operation check. WARNING LABEL CAUTION : Visible and Invisible laser radiation when open and interlock failed or defeated. AVOID DIRECT EXPOSURE TO BEAM. (e) VARNING : Synlig och osynling laserstrlning nr den ppnas och sprren r u
24、rkopplad. Betrakta ej strlen. (s) VARO : Avattaessa ja suojalukitus ohitettuna tai viallisena olet alttiina nkyvlle ja nkymttmlle lasersteilylle. Vlt steen kohdistumista suoraan itseesi. (f) ADVARSEL : Synlig og usynlig laserstrling nr maskinen er ben eller interlocken fejeler. Undg direkte eksponer