JVC-UXA10-cs-sm 电路图 维修手册.pdf
《JVC-UXA10-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《JVC-UXA10-cs-sm 电路图 维修手册.pdf(123页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL MICRO COMPONENT MD SYSTEM No.22011 Jan. 2003COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD. UX-A10DVD UX-A10DVD Contents Safety precaution Preventing static electricity Disassembly method Adjustment method Maintenance of MD pickup 1-2 1-3 1-4 1-39 1-47 Procedures of changing the MD picku
2、p Maintenance of DVD pickup Procedures of changing the DVD pickup Description of major ICs 1-47 1-48 1-48 1-4988 Area suffix UB - Hong Kong RadioFans.CN 收音机爱 好者资料库 1-2 UX-A10DVD 1. This design of this product contains special hardware and many circuits and components specially for safety purposes. F
3、or continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. 2. Alterations of the design or circuitry
4、of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. 3. Many electri
5、cal and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement
6、 parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not hav
7、e the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high tempe
8、rature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling. 5. Leakage currnet check (Elec
9、trical shock hazard testing) After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrica
10、l shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to
11、 a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15
12、F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC volt
13、age across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards. 2. It is the lega
14、l responsibility of the repairer to ensure that these safety standards are maintained. 3. Repairs must be made in accordance with the relevant safety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. If mains voltage selector is provided, check setting
15、for local voltage. Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pref
16、orming repair of this system. In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. (This regulati
17、on does not correspond to J and C version.) RadioFans.CN 收音机爱 好者资料库 1-3 UX-A10DVD CN101 Sorting round point CN101 Flexible wire Servo control board DVD mechanism assembly MD mechanism assembly CN321 Pickup Soldering Preventing static electricity 1.Grounding to prevent damage by static electricity El
18、ectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 2.About the earth processing for the destruction prevention by stati
19、c electricity Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. 2-1 Ground the workbench Ground the workbench by laying conductive material (such as a condu
20、ctive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it. 2-2 Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup 1. In order to maintain quality during transport and before instal
21、lation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) 2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source
22、 can easily destroy the laser diode. Attention when traverse unit is decomposed 1.Solder is put up before the card wire is removed from connector on the CD substrate as shown in Figure. (When the wire is removed without putting up solder, the pick-up assembly might destroy.) 2.Please remove solder a
23、fter connecting the card wire with when you install picking up in the substrate. *Please refer to Disassembly method in the text for pick-up and how to detach the substrate. (caption) Anti-static wrist strap Conductive material (conductive sheet) or iron plate RadioFans.CN 收音机爱 好者资料库 1-4 UX-A10DVD R
24、emove the six screws A on the back of the body. Remove the screw B on each side of the body. Detach the rear side of the metal cover upward while pulling the lower sides outward. 1. 2. 3. Disassembly method Removing the metal cover (See Fig.13) Fig.1 Fig.2 Fig.3 A A A Metal cover Metal cover Metal c
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-UXA10-cs-sm 电路图 维修手册 JVC UXA10 cs sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
Tonsil ZgB-110-8-693 Mildton 110 - Schemat.zip
LUMOPHON nah28.gif