1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB429 2005/7 MICRO COMPONENT SYSTEM MB42920057 UX-G3, UX-G4 Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 5TROUBLESHOOTING . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 CA-UXG3SP-UXG3SP-UXG3 CA-UXG4SP-UXG4SP-UXG4 Area suffix US - Singapore UB - Hong Kong UP - Korea UT - Taiwan UW - Brazil,Mexico,Peru UY - Argentina UX-G3 Area suffix UX-G4 A - Australia US - Sin
5、gapore UB - Hong Kong UT - Taiwan UW - Brazil,Mexico,Peru RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB429) SPECIFICATION Design and specifications are subject to change without notice. Amplifier Section Output Power25 W per channel, min. RMS, driven into 4 at 1 kHz with no more than 10% total harmonic distort
6、ion (IEC268-3). Audio input sensitivity/Impedance (at 1 kHz) AUX: 500 mV/50 k Speakers Impedance4 - 16 TunerFM tuning range50 kHz intervals87.50 MHz-108.00 MHz 100 kHz intervals87.5 MHz-108.0 MHz AM tuning range9 kHz intervals531 kHz-1 710 kHz 10 kHz intervals530 kHz-1 710 kHz CD playerDynamic range
7、85 dB Signal-to-noise ratio85 dB Wow and flutterImmeasurable Cassette deckWow and flutter100 Hz - 10 000 Hz Wow and flutter0.35% (WRMS) GeneralPower requirementAC 110 V-127 V / AC 220 V-240 V (adjustable with the voltage selec- tor), 50Hz / 60Hz Power consumption52 W (at operation) 3.0 W (on standby
8、) Dimensions (W/H/D) (approx.)152 mm 233 mm 331 mm Mass (approx.)4.7 kg Speaker Section TypeFull range, bass-reflex type Speakers10 cm cone 1 Power handling capacity25 W Impedance4 Frequency range100 Hz - 15 kHz Dimensions (W/H/D) (approx.)152 mm 233 mm 188 mm Mass (approx.)1.8 kg each RadioFans.CN
9、收音机爱 好者资料库 (No.MB429)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by t
10、he manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design
11、alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris
12、- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- v
13、ice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts Lis
14、t of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire
15、hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal
16、 parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outl
17、et. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug
18、the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the
19、resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any m
20、ust not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs mus
21、t be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the cha
22、ssis. Therefore, pay attention to such burrs in the case of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ),
23、 diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal
24、part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE RadioFans.CN 收音机爱 好者资料库 1-4 (No.MB429) SECTION 2 SPECIFIC SERVICE INSTRUCTIONS This service manual does not describe SPECIFIC SERVICE INSTRUCTIONS. (No.MB429)1-5 SECTION 3 DISASSEMBLY 3.1Main body 3.1.1Removing
- 配套讲稿: