1、SERVICE MANUAL COPYRIGHT 2006 Victor Company of Japan, Limited No.MB539 2006/6 MICRO COMPONENT SYSTEM MB53920066 UX-N1SA,UX-N1SUS,UX-N1SUB, UX-N1SUF,UX-N1SUP,UX-N1SUT, UX-N1SUW,UX-N1SUY,UX-N1SUJ, UX-N1WA,UX-N1WUS,UX-N1WUB, UX-N1WUF,UX-N1WUP,UX-N1WUT, UX-N1WUW,UX-N1WUJ Lead free solder used in the bo
2、ard (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 CA-UXN1S for DIGIATL AUDIO PLAYER INLINEOUT SP-UX
5、N1SSP-UXN1S CA-UXN1WSP-UXN1WSP-UXN1W RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB539) SPECIFICATION Design and specifications are subject to change without notice. Amplifier sectionOUTPUT POWER10 W (5 W + 5 W) at 4 (10% THD) Speakers/Impedance4 - 16 Audio Input : LINE IN500 mV/47 k (at LINE IN LVL1) 250 mV/47
6、 k (at LINE IN LVL2) 125 mV/47 k (at LINE IN LVL3) Audio output : LINE OUT1.0 Vrms (47 k) (at LINE OUT LVL1) 2.0 Vrms (47 k) (at LINE OUT LVL2) Tuner sectionFM Tuning range87.50 MHz - 108.00 MHz AM Tuning range530 kHz - 1 710 kHz (in 10 kHz spacing) 531 kHz - 1 710 kHz (in 9 kHz spacing) CD player s
7、ection Dynamic range88 dB Signal-to-noise ratio93 dB Wow and flutterImmeasurable SpeakersSpeaker units8 cm cone 1 Impedance4 Dimensions (approx.) (W/H/D) 130 mm 171 mm 136 mm Mass (approx.)0.75 kg each GeneralPower requirementsAC 110/220 - 240 V (adjustable with the voltage selector except for Hong
8、Kong and Australia), 50/60 Hz AC 240 V , 50 Hz (only Australia) AC 220 V , 50 Hz (only Hong Kong) Power consumption21.0 W (Power on) 5.0 W (Standby mode) 4.5 W or less (Save mode) Dimensions (W/H/D)270 mm 68.5 mm 203 mm Mass1.8 kg RadioFans.CN 收音机爱 好者资料库 (No.MB539)1-3 SECTION 1 PRECAUTION 1.1Safety
9、Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to
10、those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers war
11、ranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor
12、can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features a
13、re identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other haz
14、ards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead rout
15、ing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal
16、 cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage
17、current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC
18、voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connec
19、tion to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0
20、.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standar
21、ds. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case
22、 of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby
23、are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sens
24、itivity) 1500 10W 0.15 F AC TYPE RadioFans.CN 收音机爱 好者资料库 1-4 (No.MB539) 1.5Important for laser products 1.CLASS 1 LASER PRODUCT 2.CAUTION : (For U.S.A.) Visible and/or invisible class II laser radiation when open. Do not stare into beam. (Others) Visible and/or invisible class 1M laser radiation whe