1、SERVICE MANUAL COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITED No.MB053 2003/9 MICRO COMPONENT SYSTEM MB05320039 UX-H35 TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2
2、SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
3、4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . 1-23 MICRO COMPONENT SYSTEM Area Suffix A - Australia RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB053) SPECIFICATION AmplifierOutput Power20 W (10 W + 10 W) at 4 (10% THD) Audio input sensitivity/Impedance (at 1 kHz) AUX 500 mV/48.75 k Speakers/Impedance4 TunerFM tuning range87.50 MHz - 108.00 MHz AM tu
5、ning range522 kHz - 1 629 kHz CD playerDynamic range85 dB Signal-to-noise ratio90 dB Wow and flutterImmeasurable Cassette deck Frequency response Normal (type I)50 Hz - 15 000 Hz Wow and flutter0.15% (WRMS) SpeakerSpeaker units Full range8.0 cm cone 1 Impedance4 Dimensions (approx.)135 mm 203 mm 190
6、 mm (W/H/D) Mass (approx.)1.7 kg each GeneralPower requirementAC IN240 V , 50 Hz DC IN12 V, 4 A Power consumption35 W (at operation) 3.0 W (on standby) Dimensions (approx.)412 mm 208 mm 275 mm (W/H/D) Mass (approx.)6.5 kg RadioFans.CN 收音机爱 好者资料库 (No.MB053)1-3 SECTION 1 PRECAUTION 1.1 Safety Precauti
7、ons (1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the man- ufacturer. Replacement parts must be identical to those us
8、ed in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty an
9、d will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the
10、protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manu- al. Electrical components having such features are iden-
11、 tified by shading on the schematics and by () on the Parts List in the Service Manual. The use of a substitute re- placement which does not have the same safety character- istics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or oth- er hazard
12、s. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing
13、 and dress should be observed, and it should be confirmed that they have been returned to normal, after reassembling. (5) Leakage shock hazard testing) After reassembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet
14、, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current
15、 from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmet
16、er having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 ohm 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor conne
17、ction to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to
18、0.5 mA AC (r.m.s.). 1.2 Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety stand
19、ards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the ca
20、se of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearb
21、y are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the JC version) RadioFans.CN 收音机爱 好者资料库 1-4 (No.MB053) 1.5Preventing static electricity Electrostatic discharge (ESD), which occurs when static electricity s
22、tored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.5.1 Grounding to prevent damage by static electricity Static electricity in the work area can destroy the optical pickup (laser diode
23、) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it
24、. (2) Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. (3) Handling the optical pickup In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup are shorted. After repl