JVC-RXV7000UF-avr-sm 电路图 维修手册.pdf
《JVC-RXV7000UF-avr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《JVC-RXV7000UF-avr-sm 电路图 维修手册.pdf(53页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2006 Victor Company of Japan, Limited No.MB502 2006/1 AUDIO/VIDEO CONTROL RECEIVER MB50220061 RX-V7000UF Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 5TROUBLESHOOTING . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB502) SPECIFICATION * : Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz) Designs and
5、Specifications are subject to change without notice. Amplifier Output Power At Stereo operationFront channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion (IEC268-3/DIN). Front channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with
6、 no more than 0.8% total harmonic distortion. At Surround operationCenter channel100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. Surround channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. AudioA
7、udio Input Sensitivity/Impedance (1 kHz)TAPE, VCR, TV SOUND/DBS, DVD:220 mV/47 k Audio Input (DIGITAL IN)*CoaxialDIGITAL 1 (DVD):0.5 V(p-p)/75 OpticalDIGITAL 2 (VCR), DIGITAL 3 (TV SOUND/DBS):-21 dBm to -15 dBm (660 nm 30 nm) Recording Output LevelTAPE, VCR:220 mV Signal-to-Noise Ratio (66 IHF/DIN)T
8、APE, VCR, TV SOUND/DBS, DVD:96 dB/62 dB Frequency Response (8 )TAPE, VCR, TV SOUND/DBS, DVD:20 Hz to 50 kHz (+1 dB, -3 dB) Bass Boost+4 dB 1 dB at 100 Hz Equalization (5 bands)63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps) VideoVideo Input Sensitivity/Impedance Composite video:DVD, VCR, DB
9、S1 V(p-p)/75 S-video:DVD, VCR,DBS(Y: luminance):1 V(p-p)/75 (C: chrominance, burst):0.3 V(p-p)/75 Component:DVD, VCR(Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output LevelComposite video:VCR, MONITOR OUT 1 V(p-p)/75 S-video:VCR, MONITOR OUT(Y: luminance):1 V(p-p)/75 (C: chrominance, bur
10、st)0.3 V(p-p)/75 Component:MONITOR OUT(Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 SynchronizationNegative Signal-to-Noise Ratio45 dB FM tuner (IHF) Tuning Range87.50 MHz to 108.00 MHz Usable SensitivityMonaural:12.8 dBf (1.2 V/75 ) 50 dB Quieting SensitivityMonaural:16.0 dBf (1.7 V/75 ) Stereo
11、:37.5 dBf (20.5 V/75 ) Stereo Separation at OUT (REC)35 dB at 1 kHz AM tuner Tuning Range531 kHz to 1 710 kHz (at 9 kHz intervals) 530 kHz to 1 710 kHz (at 10 kHz intervals) General Power RequirementsAC 220 V, 50 Hz Power Consumption200 W (at operation) 0.9 W (in standby mode) Dimensions (W H D)435
12、mm 200 mm 425 mm Mass11.4 kg RadioFans.CN 收音机爱 好者资料库 (No.MB502)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the origina
13、l design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of t
14、he product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-
15、related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics
16、are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommende
17、d replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for
18、the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform
19、 an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug
20、the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA
21、 AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth
22、ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repea
23、t each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety
24、 standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding