JVC-XDV9000-cd-sm 电路图 维修手册.pdf
《JVC-XDV9000-cd-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《JVC-XDV9000-cd-sm 电路图 维修手册.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL DVD AUDIO/VIDEO PLAYER No.A0004 Mar. 2001 COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD. XV-D9000 XV-D9000 Area Suffix J - U.S.A. This service manual is printed on 100% recycled paper. Contents Safety precautions - 1-2 Preventing static electricity - 1-3 Dismantling and assembling the t
2、raverse unit - 1-4 Important for laser products - 1-5 Importance admistering point on the safety - 1-6 Disassembly method - 1-7 Method of initializing EEPROM and display of jitter value - 1-18 Description of major ICs - 1-19 RadioFans.CN 收音机爱 好者资料库 XV-D9000 1-2 1. This design of this product contain
3、s special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should
4、be performed by qualified personnel only. 2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the warranty and will further relieve the manufacture of responsibility for p
5、ersonal injury or property damage resulting therefrom. 3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using repl
6、acement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the
7、Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubi
8、ngs, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been r
9、eturned to normal, after reassembling. 5. Leakage current check (Electrical shock hazard testing) After reassembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) t
10、o be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet , partic
11、ularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.) Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the
12、following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed met
13、al part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured Any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 1. This equipment has been designed and manufactured to me
14、et international safety standards. 2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained. 3. Repairs must be made in accordance with the relevant safety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. I
15、f mains voltage selector is provided, check setting for local voltage. Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE ! Burrs formed during molding may be left over on some parts of the chassis. Theref
16、ore, pay attention to such burrs in the case of preforming repair of this system. RadioFans.CN 收音机爱 好者资料库 XV-D9000 1-3 Preventing static electricity Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the
17、traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.1. Grounding to prevent damage by static electricity Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as DVD players. Be careful to use proper grounding in the area wh
18、ere repairs are being performed. 1.1.1. Ground the workbench 1. Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it. 1.1.2. Ground yourself 1. Use an anti-static wrist strap to release any st
19、atic electricity built up in your body. 1.1.3. Handling the optical pickup 1. In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (
20、Refer to the text.) 2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode. 1.2. Handling the traverse unit (optical pickup) 1. Do not subject the traverse unit (optical pickup) to strong shocks, as
21、 it is a sensitive, complex unit. 2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too lo
22、ng a time when attaching it to the connector. 3. Handle the flexible cable carefully as it may break when subjected to strong force. 4. It is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it Conductive material (conductive sheet) or iron plate (caption) Ant
23、i-static wrist strap RadioFans.CN 收音机爱 好者资料库 XV-D9000 1-4 Short circuit land Laser pick-up unit Flexible cable Shot with the clip Shorting Dismantling and assembling the traverse unit 1. Notice regarding replacement of optical pickup Electrostatic discharge (ESD), which occurs when static electricit
24、y stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs to the optical pickup or connected devices. (Refer to the section regarding anti-static measures.) 1. Do not touch the area around th
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-XDV9000-cd-sm 电路图 维修手册 JVC XDV9000 cd sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf