Kenwood-KD-CU-5049-Service-Manual 电路图 维修手册.pdf
《Kenwood-KD-CU-5049-Service-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Kenwood-KD-CU-5049-Service-Manual 电路图 维修手册.pdf(33页珍藏版)》请在收音机爱好者资料库上搜索。
1、This product uses Lead Free solder. This product complies with the RoHS directive for the European market. SERVICE MANUAL KDC-4551UB/455UW KDC-4651URY KDC-U449/U5049 CD RECEIVER 2010-12 PRINTED IN JA PAN B53-0835-00 (N) 223 TDF SPARE-PANEL MAIN UNIT NAMETDF PARTS No.TDF NAME KDC-4551UBY33-3382-71TDF
2、-4551UB KDC-455UWY33-3382-72TDF-455UW KDC-4651URYY33-3382-73TDF-4651URY KDC-U449 KDC-U5049Y33-3383-01TDF-U5049 KDC-U449 : Panel assy (GE20277-007A) KDC-4451UB : Panel assy (GE20277-001A) Y33-3380-21TDF-U449 KDC-U5049 : Panel assy (GE20277-010A) After replacing E2PROM (IC771 on X34), tuner setting ad
3、justment is needed. The adjustment is that to perform the “TUNER Setting Adjustment Mode” (Page 5) in the “Tuner Test Mode Specification” of “Production Test Mode”. Tuner setting adjustment after replacing E2PROM Mounting sleeve assy (GE34134-001A) Hook (GE40510-001A) x2 * Car cable (QAM1341-001) *
4、Screw set (N99-1757-15) * Carrying case (W01-1710-05) * Car cable (E30-6937-05) * Tap screw (2x8) (N80-2008-43) * Hard case assy (A02-2757-13) * Remote control unit (RC-405) (A70-2104-05) Trim plate (GE20274-001A) KDC-455UW : Panel assy (GE20277-002A) KDC-4651URY : Panel assy (GE20280-015A) * Depend
5、s on the model. Refer to the parts list. KDC-4551UKDC-455U KDC-4651U KDC-U449 KDC-U5049 RadioFans.CN 收音机爱 好者资料库 2 KDC-4551UB/455UW/4651URY KDC-U449/U5049 BLOCK DIAGRAM 1 BU DET PHONE RESET 9 5 9 BU DET 1 2 MUTE R902,903 12 2 1 1 111 D891 2 FL+B PS1-1 / PS1-2 / PS1-3 ACC5V / BU-DET PS2-1 / PS2-2 PHON
6、E PS1-1 / PS1-2 / PS1-3 PS2-1 / PS2-2P-ANT P-CON SP-OUT PHONE ACC BU 5 SW3.3V SW3.3V PON-FL 1 8 ACC5V PANEL3.3V CD1.5VCD3.3V 22 FL+B 3 2 2 FL+B E-VOL IC161 A9V SYSTEM u-COM & USB HOST Q321,341 PHONE Q970 BU DET Q971 SW 3.3V Q951,952 IC501 AUDIO CD BU5V SW5 (REMO DRV) RESET IC IC702 ILLUMI+B CONNECTO
7、R RESET SW REMO FL IC701 IC301 IC602 CN901 ILLUMI+B EN601FL601 J321 MUTE Q780 IC1 Q701 VDD3.3V to GND S701 CN601 A9V ANT E2PROM BU3.3V F-AUX J602 PANEL DET IC901 CN701 SW3.3V IC771 TUNER ROTARY ENCODER KEY ILLUMI (FL FILAMENT) RESISTOR KEY MATRIX MOTOR DRIVER IC SUPPLY POWER DC-CN etc MUTE RCA AMP P
8、OWER RCA-OUT DET SURGE- DC-CN BU5V SERVO IC (OASIS) IC540 CD 3.3V CD 1.5V IC530-532 BU BU3.3V ATOMIC (OE REMOTE) EXT REMO MECHA CD CD3.3V to MECHA J1 BU3.3V to DC CONNECTOR PANEL3.3V CD BU3.3V BU5V LOAD SW3.3V IC931 BU3.3V SW 3.3VBU5V PANEL SW3.3 Q602 BU3.3V BU5V USB5V CP i-Pod IC80 SW3.3V SW HI-SID
9、E USB5V (DC/DC) IC981 IC961 USB5V USB CN CN603 ELECTRIC UNIT (X34- ) SWITCH UNIT (X16- ) RadioFans.CN 收音机爱 好者资料库 3 KDC-4551UB/455UW/4651URY KDC-U449/U5049 1. Panel ACCENTSEARCH RETURNVOL 2. How to enter each Test Mode Test Mode nameOperation Production Test ModePress and hold 1 key and 3 key and res
10、et. Service Test Mode In the STANDBY source, while pressing and holding 2 key, press 6 key for 7 seconds. (Starting to press 2 key and 6 key at the same time can not be entered into the mode) DC Error Information ModePress and hold 3 key and 6 key and reset. Transition to Test Mode shall be availabl
11、e during DC Error detection. 3. How to release each Test Mode Reset Momentary voltage drop ACC OFF POWER OFF Panel Detach 4. Production Test Mode Default status immediately after the mode activation It shall be same as normal RST start in other than the below setting. Details Difference in action Pe
12、riod to prohibit TEL/LINE MUTE immediately after activation (normally 10 seconds) 1 second Mecha Initialize ActionProhibited Write-in to E2PROM when detecting a DC errorProhibited Demo Mode ON/OFF Setting MenuProhibited Power supply during ACC OFF (Back Up On)MUTE terminal turns OFF after 2 seconds
13、BEEP soundBeep with short-pressing in any functions Various setting value Volume30 (-10dB) BASS BOOST/LOUDOFF EQNATURAL Fader/BalanceCenter DEMO Mode SettingOFF AUX SettingON1 NAVI MUTE Setting for JapanDetecting function valid (ATT) TEST MODE RadioFans.CN 收音机爱 好者资料库 4 KDC-4551UB/455UW/4651URY KDC-U
14、449/U5049 Mode structure Some Test Modes change according to the current source. The following table shows the current source in Set and the related test mode status. KWD model sourceTest mode POWER OFF- StandbySTANDBY Test Mode TUNERTUNER Test Mode CDCD Test Mode USB- AUX- Mode content Syscon shall
15、 display the following information after entering this mode. The operation shown below shall be workable. Display contentDetails PROTEST The display is released when another operation is executed. The display will blink if sub clock is not functioning. STANDBY Test Mode Specifi cation OperationDispl
16、ay contentDetails 1 (Toggle) Syscom version display SYS0 Syscom version (Refer to Syscom Version Table) All lights ONAll lights ON (Switch to other display) 2 (Toggle) Serial No. display SN: 00000000 Serial No. display (8-digit) Display as it is in hex All lights ONAll lights ON (Switch to other dis
17、play) 3 (Toggle)All lights ON/OFFAll lights ON/OFF with toggle 4 (Toggle) Information display iPod verifi cation IC mount status display iPod: iPod: OK iPod: NG iPod: iPod verifi cation IC mount status display Blank: Verifying OK: Verifi cation IC mounted NG: Verifi cation IC not mounted : Non-iPod
18、support model All lights ONAll lights ON (Switch to other display) 5 (Toggle)Preout switch SWPREREAR SWPRESUBW Switch Preout with Toggle (1Preout/2Preout model only) 6 (Toggle)All lights ON/OFFAll lights ON/OFF with toggle SOURCE Transition Mode releaseReturn to Normal mode RETURNMode release Return
19、 to Normal mode Tuner Test Mode Specifi cation The following displays shall be indicated according to the TUNER status. StatusDisplay contentDetails TUNER IC Communication error TUNCONNG Communication to TUNER IC not available (indicated unless the mode is in Clock Display Mode). TEST MODE 5 KDC-455
20、1UB/455UW/4651URY KDC-U449/U5049 StatusDisplay contentDetails Adjustment not implemented ERR A97 . 9A For models that TUNER adjustment is necessary but not done (adjustment value: 0 x00 or 0 xFF), the following TUNER Test Mode functions are valid (“ERR” display is continuing). Display “ERR” blinks w
21、ith 250ms interval. RDS Specifi ed data reception RDSTEST Turn OFF P-CON forcibly if PS=RDS TEST is received. P-CON recovers with Power OFF/ON. ?Operations OperationDisplay contentDetails ACCENT TUNER IC display ATOMRDS Display TUNER IC version Display content is assigned by Tuner Development G. 4Pr
22、eset operation FM13A97 . 9ASwitch to either 98.3 (except for J type) BAND BAND switch operation FM13A97 . 9A Execute Band Switch as shown in the following table every time Band key is pressed in each type. SEARCH S meter voltage judgment display SMTRxx : OK SMTRxx : NG SMTRxx : S meter value xx: Cur
23、rent S meter value Determination result OK: Within S meter voltage spec NG: Out of S meter voltage spec : No LEVEL OFFSET adjustment DISP Shift to TUNER setting mode Transit to TUNER setting adjustment mode after switching to 98.3MHz Frequency: 98.3MHz, Modulation frequency: 1kHz, Modulation mode: M
24、ONO, Modulation: OFF, Deviation: 40kHz, ANT input level: 34dBV ?TUNER Setting Adjustment Mode 1. Operation (Operation after performance of above-mentioned “Shift to TUNER setting mode” item) OperationDisplay contentDetails BAND (Toggle) AUTO Adjustment Mode ASxxLxx Select TUNER adjustment method (A: