1、PRECAUTIONS FOR REPAIR For the SERIAL TEST CODE LIST of the circuit description, see Service manual (B51-5210-00) of R-SA7. For the INITIAL STATE, the BACK UP and the MICROPROCESSOR of the circuit description, see Service manual (B51- 5373-00) of R-SE7. No connection of ground line if disassemble th
2、e unit. Please connection the ground line on rear panel, PCBs, Chassis and some others. STEREO INTEGRATED AMPLIFIER/TUNER R-SE9/SE9T SERVICE MANUAL 1997-1/B51-5408-00 (K/K) 1812 This R-SE9 is E type. Illustrator is R-SE9T. * Refer to parts list on page20. band volume control auto/monoenter phones mo
3、de multi control N.B. ? downup stereo integrated amplifier/tunerR-SE9T TRAITR on/standby EX.BASS SYSTEM CONTROL ANTENNA AMGND CD IN REC PLAY SUPER WOOFER PRE OUT SPEAKERS ( 6 - 16 ) R TAPE TAPE REC PLAY MD MD AUX FM75 + - IN L RRLL Side plate (A50-1303-02) Panel* (A60-) Front glass (B10-2369-03) AC
4、power cord * (E30-) Screw terminal board (E70-0034-05) Lock terminal board (E20-0321-05) Lock terminal board (E20-0321-05) Phono jack (E63-1034-05) Phono jack (E63-1034-05) Phono jack (E63-0116-05) Phono jack (E63-1033-05) Phono jack (E63-1033-05) Rectangular receptacle (E08-0312-05) Power cord bush
5、ing (J42-0083-05) Knob (K29-6741-04) Knob (K29-6738-04) Knob (K29-6739-04) Knob (K29-6751-04) R-SE9/SE9T(K) 1P 98.4.25 14:46 yW 2 RadioFans.CN 收音机爱 好者资料库 FM indoor antenna (1) (T90-0806-05) DISPLAY SLEEPTAPE REMOTE CONTROL UNIT RC-SE9(E) 123RANDOM 456CLEAR 789P.MODE O.T.E.0+10EDIT TUNER BAND INPUT P
6、TY N.B. RDS DISPLAY MUTE TA/NEWS /INFO VOLUME CONTROL MD CDP.CALL Batteries (R6/AA) (2) AM loop antenna stand (1) (J19-3645-05) AM loop antenna (1) (T90-0820-05) Audio cords (2) (E30-0615-05) System control cord (1) (E30-2628-05) Battery cover (A09-0374-08) Remote control unit (1) (A70-1155-05) .RC-
7、SE9(E) R-SE9/SE9T CONTENTS / ACCESSORIES 2 CONTENTS / ACCESSORIES . 2 CIRCUIT DESCRIPTION.3 ADJUSTMENT.7 PC BOARD . 8 SCHEMATIC DIAGRAM . 11 EXPLODED VIEW .19 PARTS LIST.20 PARTS DESCRIPTIONS .25 SPECIFICATIONS .Back cover Contents Accessories R-SE9/SE9T(K) 1P 98.4.25 14:46 yW 3 RadioFans.CN 收音机爱 好者
8、资料库 R-SE9/SE9T 3 CIRCUIT DESCRIPTION 1. DESTINATION LIST OF TUNER 1-1 Destination List of Tuner 2. TEST MODE 2-1. Initializing The system is initialized when the power is turned on while pressing the POWER key. (1) Contents of operation All the functions are initialized. 2-2. AMP test mode using mai
9、n units keys 2-2-1. Entering the AMP test mode Turn on the power while pressing the BAND key. 2-2-2. Canceling the AMP test mode By turning off the power, the system is initialized and the test mode is canceled. 2-2-3. Contents of AMP test mode (1) Automatic POWER ON The POWER ON state is entered wh
10、enever the power is turned on while pressing the BAND key. All functions are then initialized and activated in the all-lighting mode. Sub-clock oscillation diagnosis function The oscillation diagnosis (existence of oscillation and measurement of period) of a sub-clock is performed before the test mo
11、de is entered. If the diagnosis result is OK, the system enters the test mode. If the diagnosis result is NG, the oscillation of the sub- clock is diagnosed again. If the result is OK, the system enters the test mode. If the diagnosis result is continu- ously NG five times, the system stops with ERR
12、 1 and ERR 2 displayed. (2) All-lighting mode All the fluorescent display indicators and LED lamps light when the power is turned on while pressing the BAND key. After that, the all-lighting mode is canceled when any main units key is pressed. The normal display obtained when the selector is set to
13、TUNER then appears. (3) Others The AMP test mode is not terminated even if the selector is set to positions other than TUNER. In the AMP test mode, the muting during mode selection is not controlled. However, the operation during the power-on sequence is the same as the normal operation. The SP prot
14、ection operation is also the same as the nor- mal operation. In the AMP test mode using main units keys, the keys below provide a special operation according to the posi- tion where the selector is set. The main units keys except described below and the rotary encoder provide the normal operation. (
15、4) When selector is set to TUNER KeyOperation EX. BASS keyIncrements the P.CALL every time this key is pressed. N.B. key Decrement the P.CALL every time this key is pressed. ENTER keySelects the display cyclically in the order below every time this key is pressed. 1 Write data in the unused area of
16、E2PROM, then read the written data. If the read data is the same as the written data, RAM OK is displayed in the fluorescent display indicator. If the former is different from the latter, RAM NG is displayed. 2 Set the TUNER ATT to OFF and display the S level in hexadecimal when the ENTER key is pre
17、ssed. (ATT OFF * is displayed in the fluorescent display indicator.) 3 Set the TUNER ATT to ON and display the S level in hexadecimal when the ENTER key is pressed. (ATT ON * is displayed in the fluorescent display indicator.) * The special display using the ENTER key is continued until the next ope
18、ration is carried out. (*: S LEVEL) When keys other than ENTER are pressed in items 1 to 3 above, the TUNER ATT is set to OFF and the normal display appears. The operation corresponding to the key that has been pressed is performed in this case. Desti- Receive Channel PLL DIODE SW(X14) nation BAND f
19、requency space 1Freference DSW1 DSW2 rangefrequency D26D29 FM 87.5MHz 100kHz +10.7MHz25kHz K1 108.0MHz AM 530kHz 10kHz+450kHz10kHz 11 1700kHz FM 87.5MHz 50kHz+10.7MHz25kHz E1 108.0MHz AM 531kHz 9kHz+450kHz9kHz 01 1602kHz FM 87.5MHz 50kHz+10.7MHz25kHz E3 108.0MHz (RDS) AM 531kHz 9kHz+450kHz9kHz 10 16
20、02kHz M K2 or E1 is changed the setting DSW1. X1 (DSW1=1 : K2, 0 = E1) 0 : NO DIODE1 : DIODEX : SWITCHING TRANSISTOR (5) When selector is set to positions other than TUNER ENTER key Every time this key is pressed, master VOL- UME level is selected cyclically. INITIALIZE level MAX MID MIN Value of Ma
21、ster VOLUMEPress the ENTER key. MAX86 MID40 MIN1 INITIALIZE7 R-SE9/SE9T(K) 1P 98.4.25 14:46 yW 6 RadioFans.CN 收音机爱 好者资料库 R-SE9/SE9T 4 CIRCUIT DESCRIPTION AUTO key Selects the MUTE operation and equalizer cyclically in the order below for operation display every time this key is pressed. - - MUTE ope
22、ration - Minimum - Maximum - Pre-condition- In the operation for except the AUTO key, become pre- condition equlizer . Pre condition : The equlizer becomes the condition to be pushed the AUTO key before (include N.B. circuit). (6) SERIAL TEST CODE LIST Refer to Service manual (B51-5210-00) of R-SA7
23、on page 7. BAND key Every time this key is pressed, all the displays go off and the normal display is selected cyclically. 2-3. RDS test mode using main units keys 2-3-1. Entering the RDS test mode Turn on the power while pressing the N.B. key. 2-3-2. Canceling the RDS test mode By turning off the p
24、ower, the system is initialized and the test mode is canceled. 2-3-3. Contents of RDS test mode The POWER ON state is entered whenever the power is turned on while pressing the N.B. key. All the functions are then initialized. In the RDS test mode using main units keys, the keys below provides a spe