1、COMPACT Hi-Fi COMPONENT SYSTEM RXD-M57MP-H/M57MP-S SERVICE MANUAL (HM-537MP) 2004-8 PRINTED IN KOREA B51-5923-00 (K/K) 339 In compliance with Federal Regulations, following are repro- duction of labels on, or inside the product relating to laser product safety. KENWOOD Corp. certifies this equipment
2、 conforms to DHHS Regulations No.21 CFR 1040. 10, Chapter 1, subchapter J. DANGER : Laser radiation when open and interlock defeated. AVOID DIRECT EXPOSURE TO BEAM. Caution : No connection of ground line if disassemble the unit. Please connect the ground line on rear panel, PCBs, Chassis and some ot
3、hers. 70% Front cabinet assy * (A60-) Knob(Open/Close) (K29-8416-08) Knob(EQ/Bass) * (K29-) Knob(Volume) (K29-8413-08) Control panel * (A21-) Knob(Demo) * (K29-) Knob(Prog) * (K29-) CD Door * (A29-) Knob(Power) (K29-8417-08) Knob(Function) (K29-8414-08) Knob(Stop/REC) (K29-8415-08) Cass lid assy * (
4、A53-) Rubber foot (G11-2961-08) Knob(Play) * (K29-) Phone jack (E11-0981-08) * Refer to parts list on page 20. RadioFans.CN 收音机爱 好者资料库 Remote control unit (1) (A70-1688-08) AM loop antenna (1) (T90-0908-08) FM ANT Wire (1) (T90-0918-08) Batteries (R6/AA) (2)AC plug adapter (1) (E03-0115-05) Use to a
5、dapt the plug on the power cord to the shape of the wall outlet. (Accessory only for regions where use is necessary.) RXD-M57MP 2 CONTENTS / ACCESSORIES / CAUTIONS CONTENTS / ACCESSORIES / CAUTIONS.2 EXTERNAL VIEW.3 ADJUSTMENT.4 PC BOARD .8 SCHEMATIC DIAGRAM .13 EXPLODED VIEW .19 PARTS LIST.20 SPECI
6、FICATIONS.BACK COVER CONTENTS ACCESSORIES SYSTEM CONFIGURATION CLASS 1 LASER PRODUCT LASER KLASSE 1 APPAREIL A LASER DE CLASSE 1 LUOKAN 1 LASERLAITE KLASS 1 LASERAPPARAT The marking this product has been classified as Class 1. It means that there is no danger of hazardous radiation outside the produ
7、ct. Location: Bottom Resetting the Microcomputer The microcomputer may malfunction (unit can- not be operated, or shows an erroneous dis- play) if the power cord is unplugged while the power is ON, or due to some other external factor. If this happens, execute the following procedure to reset the mi
8、crocomputer and return the unit to its normal operating condition. Plug in the AC power cord to the wall outlet, and within 5 seconds, press and hold down the 7button and press CD button. Please note that resetting the microcomputer will clear the contents of the memory and return the unit to the st
9、ate it was in when it left the factory. CAUTIONS SYSTEMRECEIVERSPEAKERS HM-537MP-HRXD-M57MP-HLS-M57-H HM-537MP-SRXD-M57MP-SLS-M57-S RadioFans.CN 收音机爱 好者资料库 RXD-M57MP 3 EXTERNAL VIEW 220-240V 110-120V VOLTAGE SELECTOR Top cabinet (A01-3943-08) FM 75 ohm Ant. (E70-0200-08) Rear cabinet (A80-4494-08) V
10、oltage SW. * (S62-0124-08) * Refer to parts list on page 20. RadioFans.CN 收音机爱 好者资料库 RXD-M57MP 4 ADJUSTMENT SERVICE ADJUSTMENT Lubrication The mechanical parts are factory coated with a thin coat of light grease and should not require further lubrication. If a light grease is applied, be careful not
11、 to get any grease on the play/record head or erase head, hubs, pulleys, tapes reels, drive belts, or switches. Use a good lubricant such as Silicon Lube G322L or Lubricate. Service Check Before aligning the mechanism, wipe off any accumulated dirt with denatured alcohol. Wipe around parts where the
12、 tape contacts and around all rotating parts. Drive belts are specially processed. Do not clean them with alcohol. Mechanical Torque Use a cassette type torque gauge and check the tape mechanism. Take-up torque 35 to 70 g-cm Rewind torque 50 g-cm min. Fast forward torque 50 g-cm min. Pinch Wheel Pre
13、ssure No adjustment to the pinch roller spring is necessary. It should be sufficient to give at least 40 g-cm pull force. Tape Head Servicing Each time the unit is serviced, the face of all heads should be thoroughly cleaned with denatured alcohol or commercial head cleaning solution. The playback h
14、ead should be demagnetized with a commercial demagnetizer. Accumulation of tape oxide during normal operations can cause problems, including loss of high frequencies and wow and flutter. Erase Head The erase head is properly aligned when the tape rides directly between the tape guide on the head wit
15、hout crinkling the tape. Play/Record and Playback Head Azimuth Adjustment To adjust the play/record and playback head azimuth screw: 1. Connect two (2) VTVMs and a dual trace scope to the stereo headphone jack (as shown) with a 32 ohm dummy load. (See Figure 1.) VTVMVTVM DUMMY LOAD JK400 SCOPE CH1 C
16、H2 Figure 1. Azimuth Adjustment RXD-M57MP 5 ADJUSTMENT 2. Insert a 10 kHz test tape (Teac MTT-1141V or Equivalent) into the tape mechanism and play it back. 3. While playing back the test tape, slowly turn the azimuth adjusting screw until the amplitude of both channel output waveforms is maximum an
17、d in phase. Note: Reiteration adjusting Right, lift the screw, until the amplitude of both channel output waveform is maximum. (See Figure 2.) 4. Secure the azimuth screw in place with glue or paint after making the adjustment. Figure 2. Head Output Signal Tape Speed Adjustment 1. Set the function s
18、witch to TAPE. 2. Connect a frequency counter with a 32 ohm dummy load to the stereo headphone jack. (See Figure 3.) FREQUENCY COUNTER DUMMY LOAD JK400 Figure 3. Tape Speed Adjustment 3. Insert and play back a 3 kHz test tape (Teac MTT-111 or Equivalent) into the tape mechanism. 4. Insert an insulat
19、ed alignment tool and adjust the tape speed potentiometer (MOTOR) until the frequency counter indicates 2940 Hz to 3090 Hz. Bias Oscillator Frequency and Level Adjustment 1. Set the function switch to TAPE and the record and play tape mechanism to RECORD. 2. Connect a VTVM and frequency counter to t
20、est point R/P HEAD. 3. Adjust bias oscillator coil L203 until the frequency counter indicates 67 kHz 0.5 kHz. RXD-M57MP 6 ADJUSTMENT TUNER ALIGNMENT PROCEDURE Equipment needed: 1. AM Signal generator 2. FM Signal generator 3. DC Voltage meter 4. Oscilloscope 5. Output meter (VTVM) AM Alignment Step
21、S/G Frequency Dial SettingIndicator Adjust Remarks 1 450 kHz (1 kHz 30% mod.) 612 kHz Connect oscilloscope or VTVM to speaker jack T101 Adjust for maximum output 2 531 kHz (1 kHz 30% mod.) Low end Connect DC voltage meter to test point Vt and ground L102 Adjust until Vt equal to 1.5 0.05V 3 1602 kHz
22、 (1 kHz 30% mod.) High end Same as step 2 Confirm Vt: 6.58.5V 4 612 kHz (1 kHz 30% mod.) 612 kHz Same as step 1 L103 Maximum output 5 1404 kHz (1 kHz 30% mod.) 1404 kHz Same as step 1 TC101 Maximum output 6 Repeat steps 4 and 5 to minimize tracking error 7 999 kHz (1 kHz 30%mod.) 999 kHz Same as ste
23、p 1 Offset is less than 6 dB. 60 cm AM SIGNAL GENERATOR AM LOOP ANT AM LOOP ANTENNA DUMMY LOAD VTVM TEST UNIT Figure 4. AM IF/RF Tracking RXD-M57MP 7 ADJUSTMENT FM Alignment: TEST UNIT Figure 5. FM Band Frequency Coverage Alignment Connect FM S/G to ANT inputs (mod 1 kHz 22.5kHz dev.) Step S/G Frequ
24、ency Dial Setting Indicator Adjust Remarks 1 87.5 MHz Low end Connec t DC Voltage meter to test point Vt and ground Confirm Vt: 1.7 0.2V 2 108 MHz High end Same as step 1 Confirm Vt: 8.5 1V Figure 6. FM Band/Tracking FM GENERATOR DUMMY ANTENNA TP1 TEST UNIT DUMMY LOAD VTVM OSCILLOSCOPE Vt GROUND DC
- 配套讲稿: