Pioneer-VSXC300-avr-sm 电路图 维修手册.pdf
《Pioneer-VSXC300-avr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Pioneer-VSXC300-avr-sm 电路图 维修手册.pdf(134页珍藏版)》请在收音机爱好者资料库上搜索。
1、PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS SERVICE, INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singap
2、ore 159936 ? ? ? ? ? ? PIONEER CORPORATION 2001c ORDER NO. Type Model Power RequirementRemarks VSX-C300VSX-C300-S HYXJIAC220-230V HVXJIAC230V RRV2506 1. SAFETY INFORMATION.2 2. EXPLODED VIEWS AND PARTS LIST.3 3. BLOCK DIAGRAM AND SCHEMATIC DIAGRAM.8 4. PCB CONNECTION DIAGRAM . 32 5. PCB PARTS LIST.4
3、6 6. ADJUSTMENT.50 CONTENTS 7. GENERAL INFORMATION . 51 7.1 DIAGNOSIS.51 7.1.1 Test Mode.51 7.1.2 Protection of the Amplifier Line . 52 7.1.3 Operation of the Fan-Control Line.53 7.1.4 Specifications of Speaker Detection.54 7.1.5 Timing Chart.55 7.2 PARTS.56 7.2.1 IC . 56 7.2.2 DISPLAY.62 8. PANEL F
4、ACILITIES AND SPECIFICATIONS.64 T ZZR AUG. 2001 Printed in Japan THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). AUDIO/VIDEO MULTI-CHANNEL RECEIVER VSX-C300 VSX-C300-S STANDBY PHONESVIDEOAUDIODIGITAL IN FRONT INPUT INPUT SIGNAL DIGITAL2DIGITAL2PROLOGICDTSMPEG VIRTUAL PHONES SURR.STE
5、REO AUDIO/VIDEO MULTI-CHANNEL RECEIVER VSX-C300 DVDTV/SATVCRFRONTTUNER MASTER VOLUME DOWNUP ? MULTI ch LR OFFON RadioFans.CN 收音机爱 好者资料库 2 VSX-C300, VSX-C300-S 1. SAFETY INFORMATION This service manual is intended for qualified service technicians ; it is not meant for the casual do-it- yourselfer. Q
6、ualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you a
7、re not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of Californ
8、ia to cause cancer, birth defects or other reproductive harm. Health and LED: Every other letter of the alphabets is displayed FL: IJKLMNOP displayed; and LED: Every other letter of the alphabets is displayed highlighted Normal display . 4. Rear-and-center-relay switch 2 key Each time the remote-con
9、trol code is received, the rear-and-center relay is toggled on or off. 5. DOLBY Pro Logic mode 3 key Distance setting for the front and center speakers: 10 feet Distance setting for the rear speaker: 5 feet STANDARD mode Speaker setting: All high volume, SW ON All settings other than the above will
10、be returned to the factory- preset values. 6. FAN ON/OFF switch 4 key The fan is turned on or off and rotates as follows: Low speed High speed Off . 7. Master volume switch 5 key The master volume is switched between minus infinity and 0 dB, and each trim is 0 dB. When the remote-control code is rec
11、eived for the first time, the master volume is set to minus infinity. 8. 9k/10k switch 6 key For the models HL, SB and SP only, when the $A55F+$A505 code is received, this switches between 9k and 10k. 9. Thermistor A/D value, time display 7 key When the remote-control code is received, the A/D value
12、 (0-255) of the thermistor is displayed on the FL display. Time is displayed until 60:00, and then stops. While the A/D value and time are displayed, if the remote-control code is received again, the display will return to the normal display. Time counting will not stop. 10. Speaker auto-detection c
13、heck 8 key When the remote-control code is received, automatic detection of the speaker starts, and the result will be displayed for 5 seconds, as C:_SW:_, where indicates connected, and indicates that no speaker is connected. 11. Analog inputs check 9 key When the remote-control code is received, f
14、orced analog inputs and 2-channel stereo mode are set for all functions. Speaker setting: All high volume, SW ON When this mode is entered, SJG:ANA will be displayed for 5 seconds. 12. STBY mode 0 key STBY mode is entered when the remote-control code is received. 52 VSX-C300, VSX-C300-S 7.1.2 Protec
15、tion of the Amplifier Line 1. Detection of abnormalities in DC circuits This detection has priority over the overload detection and abnormality detection for the fan and thermistor. If an abnormality has been detected, AMUTE is on, RELAY is off, and the AMP ERR display is flashing. Does the abnormal
16、ity continue for 5 seconds or more? Power is turned off. Yes The program restarts from the beginning. No (recovery) 2. Detection of overload This detection has priority over the abnormality detection of the fan and thermistor. If an abnormality has been detected, AMUTE is on, RELAY is off, and the O
17、VERLOAD display is flashing. Does the abnormality continue for 5 seconds or more? Power is turned off. Yes Power is turned off even if the unit has achieved recovery. No (recovery) While the unit is recovering from the abnormality, the OVERLOAD display continues flashing. 53 VSX-C300, VSX-C300-S 7.1
18、.3 Operation of the Fan-Control Line 1. Detection of the heat sink The detection is carried out every other second by taking in the voltage of the thermistor at A/D (PORT 31). 2. According to the temperature detected, the following operation will be executed: THRMO DCT Set voltage of A/D FAN STARTFA
19、N MAXSP RELAY AMUTEDisplay 0 to 0.1V 5LLLLTHDCT NG flashes for 5 seconds. 0.1V to 2.4V5 to 122(60C)LLHH 2.6V to 2.8V(70C)134 HLHH 2.8V to 3.4V(75C)145 LHHH 3.4V to 4.1V(90C)174 LHHHHEAT UP flashes for 5 seconds at 20-sec intervals. 4.1V (115C)210 LHLLOVERHEAT flashes. 31 pin15 pin25 pin64,66,67 pin1
20、9 pin If you wish to switch FAN START from H to L and FAN MAX from L to H, first set FAN START to L, then after 100 s, set FAN MAX to H. While OVERHEAT is flashing, only the POWER key is functional. 3. FAN operation Once the fan starts rotating, it continues to rotate at the same speed until the tem
21、perature falls to 65C. Once the fan starts rotating, it continues to rotate for at least 20 seconds even after the temperature falls to the above-mentioned level. 4. Detection of abnormalities in the fan If any abnormality is detected in the fan 5 seconds after it starts rotating at high speed, and
22、if H (abnormal) is indicated for the FANDCT connector, FAN STOP is displayed for 5 seconds, then the power is turned off. While FAN STOP is displayed, AMUTE is on, and RELAY is off. While FAN STOP is displayed, only the POWER key is functional. While the fan is rotating at low speed, abnormality det
23、ection is not carried out. 5. Abnormality in the thermistor If an abnormality (A/D voltage: 0.1 V or less) is detected in the thermistor, THDCT NG is displayed for 5 seconds, then the power is turned off. FAN Driver Q404 2SC2712(GRBL) Q405 DTA124EK Q402 DTA124EK R420 Q403 2SC2712(GRBL) Q406 DTA124EK