1、ORDER NO. PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS SERVICE, INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER ELECTRONIC (EUROPE) N.V. Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexa
2、ndra Road, #04-01, Singapore 159936 ? ? ? ? ? ? PIONEER CORPORATION 1999c RRV2238 1. SAFETY INFORMATION.2 2. EXPLODED VIEWS AND PARTS LIST.3 3. BLOCK DIAGRAM AND SCHEMATIC DIAGRAM.8 4. PCB CONNECTION DIAGRAM . 24 5. PCB PARTS LIST.36 6. ADJUSTMENT.39 CONTENTS 7. GENERAL INFORMATION . 40 7.1 DISASSEM
3、BLY . 40 7.2 PARTS.41 7.2.1 IC . 41 7.2.2 DISPLAY.47 8. PANEL FACILITIES AND SPECIFICATIONS.49 T ZZK NOV. 1999 Printed in Japan Type Model Power Requirement The voltage can be converted by VSX-D209VSX-D209-Gthe following method. BXJIAC110V/120-127V/220V/240VWith the voltage selector HLXJI AC220-230V
4、AC240V, THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). AUDIO/VIDEO MULTI-CHANNEL RECEIVER VSX-D209 VSX-D209-G : Alter the wiring of the Power-supply block at the primary winding of Power-transformer referring to the Line Voltage Selection described in Service Manual. RadioFans.CN 收
5、音机爱 好者资料库 2 VSX-D209, VSX-D209-G 1. SAFETY INFORMATION This service manual is intended for qualified service technicians ; it is not meant for the casual do-it- yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex
6、products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the
7、repair to a qualified service technician. WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm. Health & Safety Code Section 25249.6 Proposition 65 NOTICE (FOR
8、CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation. REMARQUE (POUR MODLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que l
9、es pices de remplacement doivent avoir la mme dsignation. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the applia
10、nce have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are i
11、dentified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended r
12、eplacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, o
13、r additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (w
14、ater pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly
15、into a 120V AC 60Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5mA. (FOR USA MODEL ONLY) Leakage current tester Reading should not be above 0.5mA Device under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as required) Ear
16、th ground AC Leakage Test RadioFans.CN 收音机爱 好者资料库 3 VSX-D209, VSX-D209-G 2.1 PACKING 1FM Wire AntennaADH7004 2AM Loop AntennaATB7009 3Polyethylene BagZ21-038 (0.03 230 340) 4 5Remote Control UnitAXD7245 (CU-VSX166) 6Battery CoverRZN1156 NSP7Dry Cell Battery (R6P, AA)VEM-013 8Left PadAHA7275 9Right P
17、adAHA7276 10Packing SheetAHG7069 11Packing CaseSee Contrast table (2) 12Operating InstructionsARE7246 (English/Chinese) 13Operating InstructionsSee Contrast table (2) (Spanish) 14AC Plug AdapterSee Contrast table (2) 15Caution 220V LabelSee Contrast table (2) (1) PACKING PARTS LIST Mark No. Descript
18、ion Part No. 2. EXPLODED VIEWS AND PARTS LIST NOTES: Parts marked by NSP are generally unavailable because they are not in our Master Spare Parts List. The mark found on some component parts indicates the importance of the safety factor of the part. Therefore, when replacing, be sure to use parts of
19、 identical designation. Screws adjacent to mark on the product are used for disassembly. 1 2 15 12 7 3 8 9 5 6 10 11 13 BXJI Type Only BXJI Type Only BXJI Type Only 14 (2) CONTRAST TABLE VSX-D209/BXJI, VSX-D209-G/BXJI and VSX-D209-G/HLXJI are constructed the same except for the following : Part No.
20、MarkNo.Symbol and DescriptionVSX-D209VSX-D209-GVSX-D209-GRemarks /BXJI/BXJI/HLXJI 11Packing CaseAHD7819AHD7821AHD7804 13Operating Instructions (Spanish)ARC7278ARC7278Not used 14AC Plug AdapterAKX7011AKX7011Not used 15Caution 220V LabelARR1003ARR1003Not used RadioFans.CN 收音机爱 好者资料库 4 VSX-D209, VSX-D2
21、09-G D L K G H M J I C I J M L K H E E B A C D F F A G B BXJI Type Only HLXJI Type Only 18 24 19 33 36 3636 40 36 36 36 36 36 36 36 36 36 36 36 36 36 36 26 15 7 1 2 5 27 36 33 22 25 40 12 13 14 16 36 17 4 3 9 8 6 36 11 35 42 36 36 37 37 38 38 36 36 36 10 Accessory of Front Panel 36 34 36 36 36 36 Re
22、fer to 2.3 FRONT PANEL SECTION. 39 39 29 28 30 41 36 36 31 32 23 21 20 BXJI Type Only BXJI Type Only 2.2 EXTERIOR SECTION 5 VSX-D209, VSX-D209-G 1MAIN AssyAWX7471 2VIDEO&6CH IN AssyAWX7383 NSP3AMP INPUT AssyAWX7382 4AMP&PRIMARY AssySee Contrast table (2) 5REGULATOR AssyAWX7389 6TRANS 2 AssyAWX7391 7
23、FM/AM TUNER UnitAXX7047 NSP8TRANS 1 AssySee Contrast table (2) NSP9TRANS 3 AssyAWX7392 10Power TransformerSee Contrast table (2) 11Fuse (FU1)See Contrast table (2) 12FFC (J31 : 30P/190 BD 60V)ADD7186 (MAIN CN102 FRONT CN402) 13FFC (J32 : 8P/170 BD 60V)ADD7187 (MAIN CN103 FRONT CN401) 14FFC (J33 : 12
24、P/200 BD 60V)ADD7188 (MAIN CN104 VIDEO&6CH IN CN305) 15FFC (J34 : 13P/80 BD 60V)ADD7189 (MAIN CN105 FM/AM TUNER CN1) 16FFC (J35 : 17P/110 BD 60V)ADD7190 (MAIN CN106 AMP INPUT CN290) 17FFC (J36 : 18P/80 BD 60V)ADD7191 (REGULATOR CN801 AMP&PRIMARY CN53) 18Strain ReliefCM-22B 19AC Power CordSee Contras
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Pioneer-VSXD209G-avr-sm 电路图 维修手册 Pioneer VSXD209G avr sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf