1、Color TelevisionChassis FR970/17 1931 Service Service Service ServiceManual ContentsContents 4. Mechanical Instructions00 6. Block Diagrams and Testpoints00 7. Electrical Diagrams and PWBsDiagramPWB WIRING DIAGRAM1 0 FRONT PANEL leakage current must not exceed 0.5milliamp. If a measurement is outsid
2、e of the specified limits, there is a possibility of shock hazard. The receiver should be repaired and rechecked before returning it to the customer. 5. Repeat the above procedure with the ac plug reversed. (Note: An ac adapter is necessary when a polarized plug is used. Do not defeat the polarizing
3、 feature of the plug.) OR With the instrument completely reassembled, plug the AC line cord directly into a 120V AC outlet. (Do not use an isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standards Institute (ANSI) C101.1
4、 Leakage Current for Appliances and Underwriters Laboratories (UL) 1410, (50.7). With the instrument AC switch first in the on position and then in the off position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed metal parts of the instrument (antennas, handle bra
5、ckets, metal cabinet, screw heads, metallic overlays, control shafts, etc.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5 milliamp. Reverse the instrument power cord plug in the outlet and repeat the test. See graphi
6、c below. PICTURE TUBE REPLACEMENT The primary source of X-radiation in this television receiver is the picture tube. The picture tube utilized in this chassis is specially constructed to limit X-radiation emissions. For continued X-radiation protection, the replacement tube must be the same type as
7、the original, including suffix letter, or a Philips approved type. PARTS REPLACEMENT Many electrical and mechanical parts in Philips television sets have special safety related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them
8、 necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. The use of a substitute part which does not have the same safety characteristics as the Philips recommended replacement part shown in this service manual may create shock, fire, or other hazards TV SAFET
9、Y NOTES SAFETY CHECKS IMPLOSION X-RADIATION PICTURE TUBE REPLACEMENT PARTS REPLACEMENT WARNING Before removing the CRT anode cap, turn the unit OFF and short the HIGH VOLTAGE to the CRT DAG ground. SERVICE NOTE: The CRT DAG is not at chassis ground. TV-VCR COMBI SAFETY NOTES IMPORTANT SAFETY PRECAUT
10、IONS Prior to shipment from the factory, our products are strictly inspected for recognized product safety and electrical codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is b
11、eing serviced. SAFETY PRECAUTIONS FOR TV CIRCUITS 1. Before returning an instrument to the customer, always make a safety check of the entire instrument, including, but not limited to, the following items: a. Be sure that no built-in protective devices are defective or have been defeated during serv
12、icing. (1) Protective shields are provided on this chassis to protect both the technician and the customer. Correctly replace all missing protective shields, including any removed for servicing convenience. (2) When reinstalling the chassis and/or other assembly in the cabinet, be sure to put back i
13、n place all protective devices, including but not limited to, nonmetallic control knobs, insulating fishpapers, adjustment and compartment covers/shields, and isolation resistor/capacitor networks. Do not operate this instrument or permit it to be operated without all protective devices correctly in
14、stalled and functioning. Servicers who defeat safety features or fail to perform safety checks may be liable for any resulting damage. b. Be sure that there are no cabinet openings through which an adult or child might be able to insert their fingers and contact a hazardous voltage. Such openings in
15、clude, but are not limited to, (1) spacing between the picture tube and the cabinet mask, (2) excessively wide cabinet ventilation slots, and (3) an improperly fitted and/or incorrectly secured cabinet back cover. c. Do a LEAKAGE CURRENT CHECK ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN
16、INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE INSTRUMENT TO THE CUSTOMER OR BEFORE CONNECTING THE ANTENNA OR ACCESSORIES. d. X-Radiation and High Voltage Limits - Because the picture tube is the primary potential source of X-radiation in solid-state TV receivers, it
17、is specially constructed to prohibit X-radiation emissions. For continued X-radiation protection, the replacement picture tube must be the same type as the original. Also, because the picture tube shields and mounting hardware perform an X-radiation protection function, they must be correctly in pla
18、ce. High voltage must be measured each time servicing is performed that involves B+, horizontal deflection or high voltage. Correct operation of the X-radiation protection circuits also must be reconfirmed each time they are serviced. (X-radiation protection circuits also may be called horizontal di
19、sable or hold down.) Read and apply the high voltage limits and, if the chassis is so equipped, the X-radiation protection circuit specifications given on instrument labels and in the Product Safety because of potential hazard, do not try to remove such permanently attached yokes from the picture tu
20、be. 5. Hot Chassis Warning a. Some TV receiver chassis are electrically connected directly to one conductor of the ac power cord and may be serviced safely without an isolation transformer only if the ac power plug is inserted so that the chassis is connected to the ground side of the ac power sourc
21、e. To confirm that the ac power plug is inserted correctly, with an ac voltmeter, measure between the chassis and a known earth ground. If a voltage reading in excess of 1.OV is obtained, remove and reinsert the ac power plug in the opposite polarity and again measure the voltage potential between t
22、he chassis and a known earth ground. b. Some TV receiver chassis normally have 85Vac (RMS) between chassis and earth ground regardless of the ac plug polarity. This chassis can be safety-serviced only with an isolation transformer inserted in the power line between the receiver and the ac power sour
23、ce, for both personnel and test equipment protection. Some TV receiver chassis have a secondary ground system in addition to the main chassis ground. This secondary ground system is not isolated from the ac power line. The two ground systems are electrically separated by insulation material that mus
24、t not be defeated or altered. 6. Observe original lead dress. Take extra care to assure correct lead dress in the following areas: a. near sharp edges, b. near thermally hot parts - be sure that leads and components do not touch thermally hot parts, c. the ac supply, d. high voltage, and e. antenna
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Philips-MX-975-D-Service-Manual1 电路图 维修手册 Philips MX 975 Service Manual 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
PHILIPS 42a.gif
Orion AR604-b.JPG