Sony-CDPEX100-cd-sch 电路图 维修手册.pdf
《Sony-CDPEX100-cd-sch 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Sony-CDPEX100-cd-sch 电路图 维修手册.pdf(7页珍藏版)》请在收音机爱好者资料库上搜索。
1、 1 CDP-EX100 SERVICE MANUAL AEP Model UK Model E Model Model Name Using Similar MechanismCDP-EX10 CD Mechanism TypeCDM28-5BD19 Base Unit NameBU-5BD19 SPECIFICATIONS COMPACT DISC PLAYER MICROFILM This set is the CD player section in MHC-EX50/EX70AV/EX100AV. RadioFans.CN 收音机爱 好者资料库 6 Note : 1.Basicall
2、y designed to operate without adjustment. Therefore, check each item in order given. 2.Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3.Use an oscilloscope with more than 10M impedance. 4.Clean the objective lens by an applicator with neutral detergent when the signal level is low than
3、specified value with the following checks. 5.Adjust the focus bias adjustment when optical block is replaced. Focus Bias Adjustment SECTION 4 ELECTRICAL ADJUSTMENTS Procedure: 1.Connect oscilloscope to test point TP (RF). (GND terminal : VC) 2.Turn Power switch on. 3.Put disc (YEDS-18) in and playba
4、ck. 4.Adjust RV101 so that the waveform is clear. (Clear RF signal waveform means that the shape “ ” can be clearly distinguished at the center of the waveform.) 5.After adjustment, check the RF signal level. RF signal VOLT/DIV : 200 mV TIME/DIV : 500 nS S Curve Check Procedure: 1.Connect oscillosco
5、pe to test point TP(FEO). 2.Connect between test point TP(FOK)and GND by lead wire. 3.Turn Power switch on. 4.Put disc (YEDS-18) in and turnd Power switch on again and actuate the focus search. (In case of using SERVICE BOX actuate the focus search when disc table is moving in and out.) 5.Check the
6、oscillosope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2.40.7 Vp-p. S-curve waveform 6.After check, remove the lead wire connected in step 2. Note : Try to measure several times to make sure than the ratio of A:B or B:A is more than 10:7. Take sweep time
7、 as long as possible and light up the brightness to obtain best waveform. RF Level Check Procedure: 1.Connect oscilloscope to test point TP (RF) on BD board. 2.Turn Power switch on. 3.Put disc (YEDS-18) in and playback. 4.Confirm that oscilloscope waveform is clear and check RF signal level is corre
8、ct or not. Note : Clear RF signal waveform means that the shape “ ” can be clearly distinguished at the center of the waveform. RF signal waveform BD board oscilloscope TP (FEO) TP (FOK) VOLT/DIV : 200mV TIME/DIV : 500nS level : 1.30.3 Vp-p BD board TP (RF) TP (VC) oscilloscope BD board TP (RF) VC o
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Sony-CDPEX100-cd-sch 电路图 维修手册 Sony CDPEX100 cd sch 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf