1、P-3000R SERVICE MANUALSERVICE MANUAL RC-797S PREAMPLIFIER Black and Silver models MODEL P-3000R(B)/(S) 120V AC, 60Hz 230V AC, 50Hz B MDC B MPP, S MPP Ref. No. 4256 012011 SAFETY-RELATED COMPONENT WARNING! COMPONENTS IDENTIFIED BY MARK ON THE SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE CRITICAL FOR R
2、ISK OF FIRE AND ELECTRIC SHOCK. REPLACE THESE COMPONENTS WITH ONKYO PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL. MAKE LEAKAGE-CURRENT OR RESISTANCE MEASUREMENTS TO DETERMINE THAT EXPOSED PARTS ARE ACCEPTABLY INSULATED FROM THE SUPPLY CIRCUIT BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER
3、. RadioFans.CN 收音机爱 好者资料库 P-3000R SERVICE PROCEDURE-1 CLEARStand-by MODEON/STANDBY VOLUME - MIN.POWER - ON VOLUME 1. Replacing the fuses 2. Safety check out (U.S.A. model only) After correcting the original service problem, perform the following safety check before releasing the unit to the customer
4、. Leakage current Check Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or metal overlays etc.). Plug the power supply cord
5、 directly into a 120Vac 60Hz wall socket and turn ON/STANDBY button on. Any current measured must not exceed 0.5mA. 3. Memory Backup This model uses a EE-PROM IC in order to retain radio presets and other settings. So, memory contents will be kept eternally with no care. 4. To initialize the unit 1.
6、 ON/STANDBY (Power On) 2. VOLUME - Except MIN. position. The unit becomes TEST MODE in the state of Volume Min. 3. MODE + ON/STANDBY. Preset memory and each mode stored in the memory, are initialized and will return to the factory settings. 4. Disconnect Power supply cord. 5. Initial setting This sy
7、mbol located near the fuse indicates that the fuse used is show operating type, For continued protection against fire hazard, replace with same type fuse, For fuse rating, refer to the marking adjacent to the symbol. Ce symbole indique que le fusible utilise est e lent. Pour une protection permanent
8、e, nutiliser que des fusibles de meme type. Ce demier est indique la qu le present symbol est apposre. REF NO.PART NAMEDESCRIPTIONPART NO.REMARKS R1282 R1283 R1284 R1285 1A-TUL-125V 1A-TUL-125V 1A-TUL-125V 1A-TUL-125V 252377T 252377T 252377T 252377T ! ! ! ! FUSE FUSE FUSE FUSE RadioFans.CN 收音机爱 好者资料
9、库 P-3000R SERVICE PROCEDURE-2 SYS1.01 MODEON/STANDBYSRC 10Y24A 6. To check version of Mian Microprocessor FW(Firmware) 1. ON/STANDBY (Power On) 2. SRC + MODE + ON/STANDBY. Press ON/STANDBY button while pushing SRC and MODE button. 3. DIGITAL Press the DIGITAL button. 4. ON/STANDBY (Power Off). Relea
10、se version is displayed. FW version is displayed. RadioFans.CN 收音机爱 好者资料库 P-3000R FIRMWARE UPDATE - 1/10 MAIN Update procedure - 1/5 Refer to “SERVICE NOTE” about the way of showing main firmware version. Preparation Hardware and Software (1) Personal computer (PC) with Windows XP. (2) Flashwriter j
11、ig: “0JFLASH” and “0JFLASHEX (for Main)”. (3) Writing soft: “flasta_exe.zip” Download and unzip “flasta_exe.zip” to extract “FlashSta.exe” etc. in advance. (4) Program: Download the latest “.mot” files for P-3000R and store in the same folder as “FlashSta.exe”. Connection and Setup (1) While the tar
12、get unit is off, connect 0JFLASH and 0JFLASHEX to RS232 port of the PC. (2) Connect the FFC of the jig to the connector slot on the rear panel of P-3000R. (3) Turn on the unit. RS232C 0JFLASH 0JFLASHEX FFC for Main (No line cut) PC P-3000R Rear Panel P-3000R FIRMWARE UPDATE - 2/10 MAIN Update proced
13、ure - 2/5 1. Start “FlashSta.exe” * When this alarm is displayed, push the reset button of the jig and click “OK” button. 2. Check “Internal flash memory”, choose the COM number the jig connected, and click “OK” button. P-3000R FIRMWARE UPDATE - 3/10 MAIN Update procedure - 3/5 3. Set “Baud rate (bp
14、s)” at 19200, “Program_intervals (ms)” at 40, and click “OK” button. * Initial setting value of Baud rate is 9600. 4. Following the procedure below, assign “.MOT” file and “.id” file. Click “Refer.” button and choose “.MOT” file you are going to write in the P-3000R. “File Path” is automatically ent
15、ered. Enter ID manually. ID of P-3000R are “53 53 42 30 33 39 34” Check “M16C/20 62”. Click “OK” button. 1 2 3 4 5 1 2 3 4 5 P-3000R FIRMWARE UPDATE - 4/10 MAIN Update procedure - 4/5 5. Click “E.P.R” button. * E.P.R = Erase + Program + Read * B.P.R = Blank + Program + Read 6. Click “OK” button, the
16、n it starts erasing and writing. 7. Dont turn off unit before it finishes. P-3000R FIRMWARE UPDATE - 5/10 MAIN Update procedure - 5/5 8. Writing is over when the sign below is shown. Click “OK” button. 9. Click “Exit” button, after ending “FlashSta.exe”, turn off the unit, remove the jig. 10. Turn o
17、n the unit and confirm the new version number. P-3000R FIRMWARE UPDATE - 6/10 USB Update procedure - 1/5 No showing the version of USB firmware on the P-3000R main unit. Preparation Hardware and Software (1) Personal computer (PC) installed USB device driver (for windows XP / windows VISTA / windows
18、 7). (2) USB cable. (3) Writing soft: “FWUpdate.exe” and “Driver” * Save these two files in the same folder. (4) Program: Download the latest “.hex” files for P-3000R. Connection and Setup (1) Connect P-3000R and PC with USB cable like the picture below. (2) Turn on the unit. P-3000R USB PC USB cabl
19、e P-3000R FIRMWARE UPDATE - 7/10 USB Update procedure - 2/5 1. Start “FWUpdate.exe”. 2. FW written in P-3000R now is displayed on the “Device Info”. Check “Update boot sector”, and click “ERASE FW”. 3. Click “OK” button. P-3000R FIRMWARE UPDATE - 8/10 USB Update procedure - 3/5 4. Erasing finishes w
20、hen the display below is shown. Then click “OK” button. Turn off the unit, please on again. 5. Click “Update FW” button. 6. Choose the “hex” file you want to write in, and click “OPEN” button. OPEN(O) P-3000R FIRMWARE UPDATE - 9/10 USB Update procedure - 4/5 7. Click “OK” button. 8. Writing in start
21、s, dont turn off the unit before it finishes. 9. Writing in finishes when the display below is shown. Click “OK” button. Turn off the unit, please on again. P-3000R FIRMWARE UPDATE - 10/10 USB Update procedure - 5/5 10. Information of the FW written in to the “Device Info” (on the left) are displaye
22、d. 11. Without problems, after finishing the “FWUpdate.exe”, turn off the unit and remove the USB cable. P-3000R EXPLODED VIEWS-1 P-3000R A140 A119 A001 A105 A103 A110 A121 A121 A113 A113 A116 A127 A122 x 2pcs. A118 A120 A124 A110 A104 A103 A015 A010 T901 T902 A150 A060 A020 A021 A029 A161 A160 A030
23、 U0020 U0021 U0022 U0023 U0010 U0018 U0011 U0015 U0016 U0017 U0012 U0013 U0014 A021 A310 A141 L=20mm A141 A142 A061 A117 A131 A132 A100 A102 A125 A125 A106 A021 A062 A012 A005 A307 A016 A006 A002 A003 P1006D P9303A P9901 A200 A004 x 4 pcs. A112 x 3 pcs. A121 x 3 pcs. A115 x 3 pcs. A126 x 2 pcs. A025
24、 x 2 pcs. A009 x 2 pcs. A124 x 4 pcs. A124 x 3 pcs. A124 x 11 pcs. A134 x 3 pcs. A134 x 12 pcs. A133 x 2 pcs. A152 x 4 pcs. A153 x 4 pcs. A154 x 4 pcs. A151 x 8 pcs. A011 x 6 pcs. A025 x 4 pcs. A026 x 2 pcs. A027 x 2 pcs. A028 x 2 pcs. A055 x 2 pcs. A056 x 2 pcs. A025 x 4 pcs. A032 x 8 pcs. A025 x 3