Technics-SL1200MK7-tt-sm 电路图 维修手册.pdf
《Technics-SL1200MK7-tt-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Technics-SL1200MK7-tt-sm 电路图 维修手册.pdf(37页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2019. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1904002CE A6 Direct Drive Turntable System Model No.SL-1200MK7PP SL-1210MK7EB SL-1210MK7EG Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General G
2、uidelines- 3 1.2. Caution For AC Cord (For EB)- 4 1.3. Safety Parts Information- 4 2 Warning- 5 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices- 5 2.2. General description about Lead Free Solder (PbF)- 5 3 Specifications - 7 4 Location of Controls and Com
3、ponents - 8 5 Troubleshooting Guide- 9 5.1. No Power- 9 5.2. LED Blinking-11 5.3. No Sound (Large humming noise) -12 5.4. Turntable Does Not Operate (No rotation) -13 5.5. LED No Illumination-14 6 Disassembly and Assembly Instructions -16 6.1. Types of Screws- 17 6.2. Disassembly Flow Chart - 18 6.3
4、. Main Components and P.C.B. Locations- 18 6.4. Disassembly of Slip Mat Assy and Turntable Assy- 19 6.5. Disassembly of Pitch Knob and Power SW Knob- 19 6.6. Disassembly of Insulators- 19 6.7. Disassembly of Bottom Chassis Assy- 20 6.8. Disassembly of DC Motor- 20 6.9. Disassembly of Phono Out P.C.B
5、.- 20 6.10. Disassembly of Tone Arm All Assy, Queuing Knob and Armrest Assy- 21 6.11. Disassembly of Main P.C.B.- 22 6.12. Disassembly of Pitch P.C.B. Assy- 24 6.13. Disassembly of Stylus Light Unit Assy (With LED P.C.B.) and Stylus SW P.C.B. - 24 6.14. Disassembly of SMPS P.C.B.- 25 RadioFans.CN 收音
6、机爱 好者资料库 2 6.15. Disassembly of Operation Assy -25 6.16. Disassembly of SW P.C.B.-26 6.17. Disassembly of Panel P.C.B.-26 6.18. Disassembly of Strobe P.C.B.-26 7 Measurements and Adjustments -27 7.1. Service Mode Startup Procedure -27 7.2. PITCH ADJ Center Position Adjustment -28 7.3. Automatic Adju
7、stment-29 8 Block Diagram -30 9 Wiring Connection Diagram-31 10 Exploded View and Replacement Parts List-32 10.1. Electrical Replacement Parts List-32 10.2. Mechanical Replacement Part List -33 10.3. Cabinet Parts Location 1-35 10.4. Cabinet Parts Location 2 -36 10.5. Packaging-37 RadioFans.CN 收音机爱
8、好者资料库 3 1Safety Precautions 1.1.General Guidelines 1. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that
9、 these critical parts should be replaced with manufacturers specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modify the original design without permission of manufacturer. 2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis
10、is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during servicing. 3. When se
11、rvicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 5. After s
12、ervicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards. (This “Safety Precaution” is applied only in U.S.A.) 1. Before servicing, unplug the power cord to prevent an electric shock. 2. When replacing parts, use only manufacturers recommended c
13、omponents for safety. 3. Check the condition of the power cord. Replace if wear or damage is evident. 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc. 5. Before returning the serviced equipment to the customer, be sure to make the following
14、 insulation resistance test to prevent the customer from being exposed to a shock hazard. 1.1.1.Leakage Current Cold Check 1. Unplug the AC cord and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed m
15、etallic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1M and 5.2M. When the exposed metal does not have a return path to the chassis, the reading must be 1.1.2.Leakage
16、Current Hot Check 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Fi
17、gure 1-1. 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at
18、any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipme
19、nt should be repaired and rechecked before it is returned to the customer. Figure 1-1 RadioFans.CN 收音机爱 好者资料库 4 1.2.Caution For AC Cord (For EB) Figure 1-2 1.3.Safety Parts Information Safety Parts List: There are special components used in this equipment which are important for safety. These parts
20、are marked by in the Schematic Diagrams, Exploded View & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer. (10 5 (10 am
21、pere) A 10-ampere fuse is fitted in this plug. SafetyRef No.Part No.Part Name & DescriptionRemarks 12TKFE46501AC HOLDER 28TZTKF02BC3ETOP PANEL ASSYEB EG 28TZTKF01AH9UTOP PANEL ASSYPP 30TZTKF03BC3EBOTTOM CABINET ASSYEB EG 30TZTKF02AH9UBOTTOM CABINET ASSYPP A1K2CT3YY00096AC CORDEB A1K2CG3YY00219AC COR
22、DPP A1K2CM3YY00055AC CORDEG A2TQBM0410OI (En/Cf)PP A2TQBM0411OI (En/Ge/Fr/It/Sp/Da/Du/Sw/Fi/Po)EG A2TQBM0412OI (En)EB PCB7TNPA7015AASMPS P.C.B. 5 2Warning 2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensi- tive (ES) Devices Some semiconductor (solid state) devices can be dam