Onkyo-TXRZ920-avr-sm 电路图 维修手册.pdf
《Onkyo-TXRZ920-avr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Onkyo-TXRZ920-avr-sm 电路图 维修手册.pdf(237页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service Manual Onkyo Corporation 2017 Not Applicable to Repair Please exchange the unit. Accessary Parts and Packing Material are described in Parts List. Ref.No. : 4754 Pre Issue Final Issue TX-RZ920 AV Receiver Title Page CONTENTS Title Page (This page) Service Notes Note for Parts List Panel Rese
2、t Diagnostic Function WiFi 5GHz Setting Model and Destination Firmware Check Idling Current Hookup and Setting Trouble Shoot Disassembly Schematic Diagram Exploded View Appendix THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). Model Color Type Power Requirement Remarks TX-RZ920 (B) -
3、 BlackMDC AC 120 V Canada/USA/(Mexico) TX-RZ920 (B) - BlackMGR AC 220 V to 230V China RadioFans.CN 收音机爱 好者资料库 5 4 3 2 1 6 D C A B D C A B 5 4 3 2 1 6 COMMON Service Notes Service Notes 1. Safety-related component warning! Components identified by mark on the schematic diagram and by mark “!” in the
4、parts list are critical for risk of fire and electrical shock. Replace these components with ONKYO parts whose part numbers appear as shown in this manual. 2. Safety check after servicing (1) To ensure safety, check that the covered insulating sheet or tube are removed, all parts and wires which are
5、 removed or disconnected while servicing have been put back to their original positions after servicing. (2) To insure structural integrity, check that all the screws or mechanical parts have been put back in their original positions after servicing. (3) Check that in the process of servicing or rep
6、lacing parts that the surrounding area has not been contaminated or adversely affected. (4) After servicing an insulation check on the external metal connectors and between the blades of the power plug must be performed. Method of checking insulation resistance Unplug the power cord and short the bo
7、th ends of the plug with a jumper wire. Using a 500V insulation resistance tester, check that the insulation resistance value between the plug of the power cord and externally exposed metal parts is 1M or greater. The mechanical power switch should be turned on if it is available. 3. Caution on repl
8、acing the battery Danger of explosion if rechargeable batteries is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. When disposing of used batteries, please comply with governmental regulations or environmental public institutions rules that apply
9、in your country / area. 4. Other Cautions When AC plug is non-polarized and if Main or Primary fuse enters in the Neutral line of AC Mains supply or if there is possibility of Main or Primary Fuse entering in the Neutral line of AC Mains supply, then AC Mains supply must be disconnected to de-energi
10、ze the circuit. Be sure to use only lead free solder. When soldering, please be careful not to use too much solder and affect adjacent components. This service manual is intended for qualified service technicians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necess
11、ary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repa
12、ir of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. RadioFans.CN 收音机爱 好者资料库 5 4 3 2 1 6 D C A B D C A B 5 4 3 2 1 6 COMMON Note for Parts List D 120V AC G 220230V H 220230240V J 100V AC M 220240V AC P 230V AC U 100240V A
13、C V 110240V W 120V220240V Z 1 Speaker System (without AMP.) : 0 Passive Subwoofer F Front Speaker C Center Speaker R Rear Speaker B Back Speaker A Australia B United Kingdom C North American D USA F Taiwan J Japan K Korea L Russia P Europe Q Hong Kong R China S Brazil T Thai U Worldwide Speaker Syst
14、em (without AMP.) : L Left channel R Right channel 0 Center channel Voltage Destination When parts list is EXCEL file, please refer to the following explanation about file name. P L _ T X S R 3 4 3 ( B ) M J J . x l s x Model No. Color (X) Not related to color (B) Black (M) Wood (BR) Brown (O) Orang
15、e (C) Cherry (P) Pink (G) Gold (R) Red (GR) Green (S) Silver (H) Gray (V) Violet (K) Black (W) White (L) Blue (Y) Yellow (LB) Light Blue Destination Look at the rear panel serial number 6 digit. J Voltage Look at the rear panel serial number 5 digit. J Color File Name of Parts List File (EXCEL File)
16、 1 There is a charge function and a power supply (adapter) is needed, but an adapter isnt bundled. RadioFans.CN 收音机爱 好者资料库 1 A B C D E 23456 123456 A B C D E Panel TX-RZ920 Front Panel Rear Panel Remote Control Unit RC-911R Dimensions (W H D) : 435 mm 201 mm 453 mm (17-1/8 7-15/16 17-13/16) Weight :
17、 16.3 kg (35.9 lbs.) (North American), 16.6 kg (36.6 lbs.) (China) Accessory 1. Remote controller (RC-911R) (1) 2. Batteries (AAA/R03) (2) 3. Speaker setup microphone (1) 4. Indoor FM antenna (1) 5. AM loop antenna (1) 6. Power cord (1) 5 4 3 2 1 6 D C A B D C A B 5 4 3 2 1 6 TX-NR474/NR575E TX-NR57
18、5/NR676/NR676E/777 TX-RZ620/RZ720/RZ820/RZ920 HT-R997 DRX-2.1/3.1 Reset 【STORE】 SETUP + ENTER x 2 【RESET】 1. Volume 40 2. TONE + ON/STANDBY RETURN x 2 3. Unplug the power cord from AVR after the disappeared All Clear of FL tube and AVR goes standby. 【RECALL】 SETUP + RETURN x 2 Detail Key Operation i
19、s here. Reset Protection 543216 D C A B D C A B 543216 TX-RZ920 Process List Item (signal name) Detection MethodStatus of EquipmentWarning Indication Service information display Recovery Procedure DC detection (XDCERR) Observe with 20 msec interval and Decide by 2 times continuously low level detect
20、ion. Case A) When detect XDCERR continuously after previously shutdown by XDCERR. (At the start of power on) 1)MUTE on and Speaker Relay off. 2)Flashes “AMP ERR”. 3)Shuts down when abnormality continues for more than 3 seconds. *Operation (except recovery procedure) is disabled. Case B) When detect
21、XDCERR while normal operation. 1)MUTE on and Speaker Relay off. 2)Flashes “AMP ERR”. 3)Shuts down when abnormality continues for more than 3 seconds. *Operation (except recovery procedure) is disabled for 1 minute. Case A) Blinks MCACC LED indicator. Case B) Blinks FLOFF LED indicator. DC(TuneDown)
22、+ Zone2 ON/OFF(long press) Over Current Detection (XOLERR) Observe with 20 msec interval and Decide by low level detection. Shut downBlinks Wireless LED indicator.OLPOWER ON Combination of DC and Overcurrent Decide by Over Current detection within 3 seconds after DC detection. Shut downBlinks Wirele
23、ss LED indicator.COMPOWER ON Overheat Detection (TEMPERR5) Observe with 20 msec interval and Decide by 2 times continuously low level detection. 1)Flashes “AMP OVERHEAT”. 2)Shuts down when abnormality continues for more than 3 seconds. *Operation (except recovery procedure) is disabled for 1 minute.
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Onkyo-TXRZ920-avr-sm 电路图 维修手册 Onkyo TXRZ920 avr sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


