Technics-STG30-ms-sm 电路图 维修手册.pdf
《Technics-STG30-ms-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Technics-STG30-ms-sm 电路图 维修手册.pdf(89页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2016. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1603030CE A6 Music Server Model No.ST-G30E ST-G30PP ST-G30LE ST-G30LPP Product Color: (S).Silver Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General Guidelines- 3 1.2. B
2、efore Repair and Adjustment- 4 1.3. Protection Circuitry- 4 1.4. Caution For AC Cord (For EB)- 5 1.5. Safety Parts Information- 6 2 Warning- 7 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices- 7 2.2. Caution for Lithium Battery- 7 2.3. Precaution of Laser
3、Diode- 8 2.4. General description about Lead Free Solder (PbF)- 8 2.5. Handling Precautions for Traverse Assy- 9 2.6. Grounding for electrostatic breakdown prevention - 9 3 Service Navigation-11 3.1. ST-G30 controller-11 3.2. Install SSD (For ST-G30E/PP Only)-12 3.3. Connection with the music server
4、- 14 4 Specifications- 16 5 Location of Controls and Components- 17 5.1. Main Unit Key Button Operation- 17 6 Service Mode- 19 6.1. Entering Service Mode - 19 6.2. Service Mode Menu- 20 7 Troubleshooting Guide - 21 7.1. Preparation - 21 7.2. No Power- 22 7.3. Immediately Power Falls- 28 7.4. Technic
5、s Music App No Display- 36 7.5. IMPORT/BACKUP Failure- 44 7.6. USB-DAC No Detect- 48 7.7. CD No Work- 52 7.8. SSD No Access - 55 7.9. LED No Lighting- 60 7.10. LED No Lighting (AC input, SMPS P.C.B. operate normal)- 67 RadioFans.CN 收音机爱 好者资料库 2 7.11. After Replacement Digital P.C.B., Please Adjust T
6、ime Clock-68 7.12. LED Display State-69 8 Disassembly and Assembly Instructions-71 8.1. Type of Screws -71 8.2. Disassembly Flow Chart-72 8.3. Main Components and P.C.B. Locations-73 8.4. Disassembly of Top Cabinet Unit -74 8.5. Disassembly of Side AL Panel (L) & (R) Unit -74 8.6. Disassembly of Fro
7、nt AL Panel-74 8.7. Disassembly of Power Switch P.C.B. -75 8.8. Disassembly of CD O/C Switch P.C.B -75 8.9. Disassembly of CD Drive Unit -76 8.10. Disassembly of Digital P.C.B. -76 8.11. Disassembly of SSD Drive-77 8.12. Disassembly of SSD P.C.B. -77 8.13. Disassembly of Main P.C.B.-78 8.14. Disasse
8、mbly of AC Inlet P.C.B.-79 8.15. Disassembly of SMPS P.C.B. -79 9 Service Position-80 9.1. Checking P.C.B. -80 10 Block Diagram -81 10.1. Signal Section-81 10.2. Power Supply Section -82 11 Wiring Connection Diagram-83 12 Exploded View and Replacement Parts List-84 12.1. Cabinet Parts Location 1-84
9、12.2. Cabinet Parts Location 2-85 12.3. Packaging-86 12.4. Mechanical Replacement Part List -87 12.5. Electrical Replacement Parts List-89 RadioFans.CN 收音机爱 好者资料库 3 1Safety Precautions 1.1.General Guidelines 1. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are imp
10、ortant for safety. These parts are marked by in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modif
11、y the original design without permission of manufacturer. 2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in
12、personal injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during servicing. 3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short cir
13、cuit. 4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards. (This “Safety Precaution” is a
14、pplied only in U.S.A.) 1. Before servicing, unplug the power cord to prevent an electric shock. 2. When replacing parts, use only manufacturers recommended components for safety. 3. Check the condition of the power cord. Replace if wear or damage is evident. 4. After servicing, be sure to restore th
15、e lead dress, insulation barriers, insulation papers, shields, etc. 5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the customer from being exposed to a shock hazard. 1.1.1.Leakage Current Cold Check 1. Unplug the AC cor
16、d and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to
17、the chassis, the reading should be between 1M and 5.2M. When the exposed metal does not have a return path to the chassis, the reading must be 1.1.2.Leakage Current Hot Check 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a 1.5k, 10 wa
18、tts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1-1. 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor. 4. Check each exposed
19、metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leak
20、age current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer. Figure 1-1 RadioFans.CN 收音机爱 好者资料库 4 1.2.Before Repair and Adjustmen
21、t Disconnect AC power to discharge AC Capacitors (C1700, C1701, C1702, C1703, C1704, C1706, C1714) through a 10 , 10 W resistor to ground. Figure 1-1 Caution: DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices. After repairs are completed,
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Technics-STG30-ms-sm 电路图 维修手册 Technics STG30 ms sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf