Marantz-SR3000-avr-sm 电路图 维修手册.pdf
《Marantz-SR3000-avr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SR3000-avr-sm 电路图 维修手册.pdf(77页珍藏版)》请在收音机爱好者资料库上搜索。
1、AV Surround Receiver TABLE OF CONTENTS SECTIONPAGE 1. LOCATION OF PRINTED CIRCUIT BOARDS/VERSION VARIATIONS . 1-1 2. TECHNICAL SPECIFICATION. 1-3 3. SERVICE TOOL/MEASUREMENT SET UP/SAFETY . 1-5 4. WARNING/HANDLING CHIP COMPONENTS . 1-6 5. DISMANTLING HINTS . 2-1 6. ABREVIATIONS . 2-2 7. WIRING DIAGR
2、AM. 3-1 8. BLOCK DIAGRAM. 4-1 9. SERVICE TEST PROGRAM .5-1 10. FRONT BOARD.6-1 11. TUNER BOARD ECO5.7B-1 12. TUNER 95 BOARD. 7D-1 13. DOLBY PROLOGIC BOARD .8-1 14. MULTI-CHANNEL DECODING MODULE. 9-1 15. MAINS BOARD. 10-1 16. MONO BOARD . 11-1 17. EXPLODED VIEW . 12-1 18. ELECTRICAL PARTS LIST MONO B
3、OARD . 13-1 Service Manual SR3000 /N1B, /U1B SR4000 /K1B, /K1G, /N1B, /U1B Please use this service manual with referring to the user guide (D.F.U) without fail. R SR3000 / SR4000 283W855010 ACT 3120 785 22200 First Issue:2000.03 SR3000 SR4000 RadioFans.CN 收音机爱 好者资料库 MARANTZ DESIGN AND SERVICE Using
4、superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound. Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous. Parts for your MARANTZ equipment are generally availab
5、le to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part n
6、umbers and quantities required 3. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void. SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this a
7、ppliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins ( with unit NOT connected to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms sh
8、ould cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer. Ref. UL Standard No. 1492. In case of difficulties, do not hesitate to contact the Technical Department at above mentioned address. 991207ACT USAUSA MARANTZ AMERICA, INCMARA
9、NTZ AMERICA, INC. 440 MEDINAH ROAD ROSELLE, ILLINOIS 60172 USA PHONE : 630 - 307 - 3100 FAX : 630 - 307 - 2687 BRAZILBRAZIL PHILIP DA AMAZONIA IND. ELET. ITDAPHILIP DA AMAZONIA IND. ELET. ITDA CENTRO DE INFORMACOES AO CEP 04698-970 SAO PAULO, SP, BRAZIL PHONE : 0800 - 123123(Discagem Direta Gratuita
10、) FAX : +55 11 534. 8988 JAPANJAPAN Technical MARANTZ JAPAN, INC.MARANTZ JAPAN, INC. 35- 1, 7- CHOME, SAGAMIONO SAGAMIHARA - SHI, KANAGAWA JAPAN 228-8505 PHONE : +81 42 748 1013 FAX : +81 42 741 9190 EUROPE / TRADING EUROPE / TRADING MARANTZ EUROPE B.V.MARANTZ EUROPE B.V. P.O.BOX 80002, BUILDING SFF
11、2 5600 JB EINDHOVEN THE NETHERLANDS PHONE : +31 - 40 - 2732241 FAX : +31 - 40 - 2735578 TECHNICAL AUDIO GROUP PTY, LTDTECHNICAL AUDIO GROUP PTY, LTD 558 DARLING STREET, BALMAIN, NSW 2041, AUSTRALIA PHONE : 61 - 2 - 9810 - 5300 FAX : 61 - 2 - 9810 - 5355 CANADACANADA LENBROOK INDUSTRIES LIMITEDLENBRO
12、OK INDUSTRIES LIMITED 633 GRANITE COURT, PICKERING, ONTARIO L1W 3K1 CANADA PHONE : 905 - 831 - 6333 FAX : 905 - 831 - 6936 AUSTRALIAAUSTRALIA JAMO AUSTRALIA PTY LTDJAMO AUSTRALIA PTY LTD 1 EXPO COURT, P.O. BOX 350 MT. WAVERLEY VIC 3149 AUSTRALIA PHONE : +61 - 3 - 9543 - 1522 FAX : +61 - 3 - 9543 - 3
13、677 NEW ZEALANDNEW ZEALAND WILDASH AUDIO SYSTEMS NZWILDASH AUDIO SYSTEMS NZ 14 MALVERN ROAD MT ALBERT AUCKLAND NEW ZEALAND PHONE : +64 - 9 - 8451958 FAX : +64 - 9 - 8463554 THAILANDTHAILAND MRZ STANDARD CO.,LTDMRZ STANDARD CO.,LTD 746 - 754 MAHACHAI ROAD., WANGBURAPAPIROM, PHRANAKORN, BANGKOK, 10200
14、 THAILAND PHONE : +66 - 2 - 222 9181 FAX : +66 - 2 - 224 6795 TAIWANTAIWAN PAI- YUING CO., LTD.PAI- YUING CO., LTD. 6 TH FL NO, 148 SUNG KIANG ROAD, TAIPEI, 10429, TAIWAN R.O.C. PHONE : +886 - 2 - 25221304 FAX : +886 - 2 - 25630415 MALAYSIAMALAYSIA WO KEE HONG ELECTRONICS SDN. BHD.WO KEE HONG ELECTR
15、ONICS SDN. BHD. SUITE 8.1, LEVEL 8, MENARA GENESIS, NO. 33, JALAN SULTAN ISMAIL, 50250 KUALA LUMPUR, MALAYSIA PHONE : +60 3 - 2457677 FAX : +60 3 - 2458180 AMERICAS AMERICAS SUPERSCOPE TECHNOLOGIES, INC.SUPERSCOPE TECHNOLOGIES, INC. MARANTZ PROFESSIONAL PRODUCTS 2640 WHITE OAK CIRCLE, SUITE A AURORA
16、, ILLINOIS 60504 USA PHONE : 630 - 820 - 4800 FAX : 630 - 820 - 8103 AUSTRALIA AUSTRALIA KOREAKOREA MK ENTERPRISES LTD.MK ENTERPRISES LTD. ROOM 604/605, ELECTRO-OFFICETEL, 16-58, 3GA, HANGANG-RO, YONGSAN-KU, SEOUL KOREA PHONE : +822 - 3232 - 155 FAX : +822 - 3232 - 154 SINGAPORESINGAPORE WO KEE HONG
17、 (S) PTE LTDWO KEE HONG (S) PTE LTD WO KEE HONG CENTRE NO.23, LORONG 8, TOA PAYOH SINGAPORE 319257 PHONE : +65 2544555 FAX : +65 2502213 RadioFans.CN 收音机爱 好者资料库 VERSION VARIATIONS SR3000 Features Rt inputs. (in phase 0) 2- The next tone burst is given at the same time to the L t Rt input, but in rev
18、erse phase to the Rt input (180). These 2 tone bursts are repeated continuously during 2 minutes. -Principle description decoded signal spots in Center/Surround channel - In case of 20 msec time delay mode the results are shown in fig. 1 in Center and Surround channel. The center spots in Center cha
19、nnel can be used as Marker spots (trigger signal) repeated every 40 msec. The delayed surround spots occur at the same time as the center spots (markers) - When time delay mode is changed to 15 msec the delayed surround spots move to the left with respect to the centre mark spots. - When time delay
20、mode is changed to 25 msec or 30 msec the delayed surround spots move to the right with respect to the center spots. - In case of no time delay ! (faulty condition) the surround spots fall just between 2 center markers spots (20 msec) -How to check with a double beam scope WARNING: Be sure that the
21、ground connection (-) of each instrument is not connecteded with the safety earth connection. To avoid damage to output amplifiers (balance type) Use only cinch (input) ground connection - Select Pro Logic size “LARGE” or “SMALL” (phantom in case of no Center output.) - Select 20 msec time delay in