Marantz-SA8004v4-sacd-sm 电路图 维修手册.pdf
《Marantz-SA8004v4-sacd-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SA8004v4-sacd-sm 电路图 维修手册.pdf(97页珍藏版)》请在收音机爱好者资料库上搜索。
1、START:|g1cz3Z09ximWbk6cjE4rRA=|GtIWFamzcAisij37zhRMD+Ea8AEB/JIN3E4+aj/9EYw=|UZF8sRf4boHZE14Xtld7UA=|:END Service Manual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail
2、. For purposes of improvement, specifications and design are subject to change without notice. Super Audio CD player SA8004 /K1SG/U1B SA-KI-PEARL-LITE /N1SG/N1B dSA-KI-PEARL-LITE /N2SG/N2B SA8004 SA-KI-PEARL-LITE SA8004 SA-KI-PEARL-LITE S0886-1V04DM/DG1408Copyright 2014 D press the 3 button, and the
3、 number goes down at 1% step. Press the 2 button at any value, and the setting for Open1 will be determined (between 0 and 500ms). Once the setting is determined, it will automatically determine the setting for Open2. Likewise, determine the setting for each of Open2 to Open5 and then for each of Cl
4、ose1 to Close5. When the Close5 setting is completed, the display will show the following message: Then, press the 2 button, and the OPEN/CLOSE operation will be repeated three times at the set speed. Meanwhile, press the 1 button while this message is on the display, and the OPEN/CLOSE test will be
5、 cancelled and the model indication will return to the display. However, the setting has been memorized so that the speed will remain unchanged. Also, press the 3 button while this message is on the display, and the OPEN/CLOSE test will be cancelled, the model indication will return and the setting
6、will be cancelled. When the OPEN/CLOSE test is performed with the operation repeated three times, the display will show the following message: Press the 2 button then, and the model identifi cation will return, and the OPEN/CLOSE will be performed at the set speed. If another button is pressed, the
7、setting will be cancelled and the model identifi cation will return. Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 S_T R A YP E E D = Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 _1O p e n_ X X X % _ Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REM
8、AINTTLA- B 1 PST R Y _ T e s t ? Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 CPT R Y Sh a n g e ? 24 B The mode to check the last error message etc. This test mode is common to all models. 1. The error message displayed as the Last Error Message (1) Communication error betwee
9、n SA-CD Module and Microprocessor When having had the communication error with the SA-CD Module more than a regulated number of times, the unit will reset the SA-CD Module after displaying the following message. This will continue to be displayed until the unit has recovered from the communication e
10、rror. When the unit is ready to play back CDs and SA-CDs, the SA-CD Module and the Microprocessor communicate regularly. Check the signal in reference to the communication between the SA-CD Module and the Microprocessor on Communication Waveforms page. The MOD_SCL is the clock that is transmitted fr
11、om the SA-CD regularly. If this signal cannot be detected, the SA-CD Module may be broken. If so, replace the SA-CD Module. When the SA-CD Module has been replaced, ensure that the Playtime will be cleared. (2) Communication Error between D/A Converter and Front Microprocessor If no response is dete
12、cted in the communication between the D/A Converter and the Microprocessor, the display will show the following message. Make the CD/SA-CD or the USB replayable. Ensure that IIC communications have been established between R217 and R218 when the unit is switched from STOP to PLAY. If the error canno
13、t be corrected through normal operations, U204 may be broken. If such is the case, replace U204. 2. Error messages that are not displayed in the Last Error Message (1) Error messages that can be displayed on the FL (Communication Error between the Front Microprocessor and EEPROM) If no response is d
14、etected between the Front Microprocessor and EEPROM within a regulated timeframe, the display will show the following message. Ensure that IIC communications have been established between R123 and R125 when the unit is powered on or put into STANDBY. IF the error cannot be corrected through normal o
15、perations, U101 may be broke. If such is the case, replace U101. When no disc information is displayed 120 seconds after the disc is loaded, the display will show the following message. Reset the SA-CD Module. If no information can be obtained after this operation has been repeated three times, the
16、unit will open the tray by itself. The unit cannot play back the disc if this message appears. Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 C_S A C Do m _ E r r Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 rrD A C Eo r I I C _ Display Off RPTRNDMPROGTRKS
17、A-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 rEE R O Mr o r I I C Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 t_ C a n_ P l a y _ 25 C Error Messages special to USB 1. Error Message displayed as the Last Error Message If no response is made in the communication between the USB Mo
18、dule U501 and the microprocessor within a designated timeframe, the display will show the following message. Refer to the Communication between USB Module and the microprocessor on the Communication Waveform page and check the signal. If the error message bellow cannot be cleared despite the unit pe
19、rforming normal operations properly, U501 may be broken. If such is the case, replace U501. If no response is made in the communication with an iPod-authenticated IC within a regulated timeframe, the display will show the following message. As the communication with the authenticated IC has not been
20、 established normally, ensure that the IIC signal is communicating at a normal level when the unit is connected with an iPod. The frequency of the IIC clock (IIC_SCL) is approximately 40 kHz only when the unit communicates with an iPod- authenticated IC. If no communication can be detected, check th
21、e soldering points of the microprocessor (U102), resistors (R155, R157) and the authenticated IC (U151). If the problem specifi c to the iPod cannot be rectifi ed, the authenticated IC (U151) may be broken. If that is the case, replace U151. When the iPod-authenticated IC has received error informat
22、ion, the display will show the following message. This message means that the authenticated IC is communicating properly. Try connecting another iPod. If no problem arises with another iPod, advise the user to repair the iPod. If the same problem arises with another iPod, the authenticated IC (U151)
23、 may be broken. If that is the case, replace U151. When a problem arises with the processing of the iPod authentication and signature, the display will show the following message. If the following message appears instead of the above messages - iPodErrorIC”, iPodICErrorx and USB_Com_ Error_, try con
24、necting another iPod. If no problem arises, advise the user to repair the iPod. If the error message persists, the authenticated IC (U151) may be broken. If that is the case, replace U151. Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 oCU S B _m _ E r r _ Display Off RPTRNDMPRO
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Marantz-SA8004v4-sacd-sm 电路图 维修手册 Marantz SA8004v4 sacd sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。