Panasonic-SAMAX700GS-cs-sm 电路图 维修手册.pdf
《Panasonic-SAMAX700GS-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAMAX700GS-cs-sm 电路图 维修手册.pdf(124页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2013. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1303039CE CD Stereo System Model No.SA-MAX700GS Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General Guidelines- 3 1.2. Before Use - 4 1.3. Befor
2、e Repair and Adjustment- 4 1.4. Protection Circuitry- 4 1.5. Caution For AC Cord - 5 1.6. Caution For Fuse Replacement- 6 1.7. Safety Parts Information - 6 2 Warning- 7 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices- 7 2.2. Precaution of Laser Diode- 8 2
3、.3. Service caution based on Legal restrictions- 9 2.4. Handling Precautions for Traverse Unit-10 2.5. Grounding for electrostatic breakdown prevention- 11 3 Service Navigation - 12 3.1. Service Information- 12 3.2. Firmware Update Procedure- 13 4 Specifications- 14 5 General/Introduction- 15 5.1. M
4、edia Information- 15 6 Location of Controls and Components- 16 6.1. Remote Control Key Button Operation - 16 6.2. Main Unit Key Button Operation- 17 7 Installation Instructions - 18 7.1. Speaker and A/C Connection- 18 8 Service Mode- 19 8.1. Cold-Start - 19 Please refer to the original service manua
5、l for: ? ? CD Mechanism Unit, Order No. PSG1201019AE ? ? Speaker system SB-MAX700GSK, Order No. PSG1301011CE RadioFans.CN 收音机爱 好者资料库 2 8.2. Doctor Mode Table-20 8.3. Reliability Test Mode (CD Mechanism Unit)-23 8.4. Self-Diagnostic Mode -24 8.5. Self-Diagnostic Error Code Table -24 8.6. Sales Demons
6、tration Lock Function -25 9 Troubleshooting Guide-26 10 Disassembly and Assembly Instructions-27 10.1. Screw Types-27 10.2. Disassembly Flow Chart-28 10.3. Main Components and P.C.B. Locations-29 10.4. Disassembly of Top Cabinet-30 10.5. Disassembly of Front Panel Unit-31 10.6. Disassembly of FL Dis
7、play P.C.B. -31 10.7. Disassembly of Illumination Button P.C.B.-32 10.8. Disassembly of Control P.C.B.-32 10.9. Disassembly of Control Jog LED P.C.B.-34 10.10. Disassembly of Volume P.C.B.-34 10.11. Disassembly of Volume Jog LED P.C.B. -36 10.12. Disassembly of Remote Sensor P.C.B.-36 10.13. Disasse
8、mbly of USB P.C.B. -36 10.14. Disassembly of Mic P.C.B.-37 10.15. Disassembly of LED P.C.B.-37 10.16. Disassembly of CD Lid-38 10.17. Disassembly of Rear Panel-39 10.18. Disassembly of CD Mechanism Unit-40 10.19. Disassembly of Main P.C.B.-40 10.20. Disassembly of Digital Amplifier IC (IC2501/ IC250
9、2/IC2503/IC2504) -41 10.21. Disassembly of SMPS P.C.B. and Voltage Selector P.C.B.-42 10.22. Replacement of Switching Regulator (Q5700) -44 10.23. Replacement of Rectifier Diode (D5801)-46 10.24. Replacement of Rectifier Diode (D5802)-47 10.25. Disassembly of CD Interface P.C.B.-49 11 Service Positi
10、on-50 11.1. Checking of FL Display P.C.B., Control P.C.B., Volume P.C.B., Mic P.C.B. and USB P.C.B. -50 11.2. Checking of Main P.C.B. (Side B)-51 11.3. Checking of Main P.C.B. (Side A)-52 11.4. Checking of SMPS P.C.B.-53 12 Block Diagram -55 12.1. Servo X : NG (In case that time out happens.) : Eith
11、er one of FO AOC, TR AOC and FO coarse AGC is NG. : If the AGC is NG (ignore others). To cancel this mode, press 0 button on the remote control. To cancel this mode, press 0 button on the remote control. (Display 2) (Display 1) Version (Decimal) ROM Type Year Develop after 2 sec Checksum (Hex) 23 8.
12、3.Reliability Test Mode (CD Mechanism Unit) Below is the process flow chart of the aging test for the CD Mechanism Unit . Fig. 1. Reliability Test (Loading) Fig. 2. Reliability Test (Traverse) Fig. 3. Reliability Test (Combination) OPEN Operation OPEN wait for 1 s CLOSE Operation CLOSE wait for 4 s
13、Count up First Track Access First Track Play 5 s Last Track Access Last Track Play 5 s Count up First Track Access Access Play 10 s Open Operation Open wait for 1 s CLOSE Operation Count up First Track Last Track Last Track Play 10 s 24 8.4.Self-Diagnostic Mode 8.5.Self-Diagnostic Error Code Table S
14、elf-Diagnostic Function (Refer Section 8.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and its respective components by displaying the error codes. These error code such as U*, H* and F* are stored in memory and held unless it is cleared. The error code is auto
15、matically display after entering into self-diagnostic mode. 8.5.1.Power Supply Error Code Table FL Display Key Operation Front Key Item Description Mode Name To enter into self diagnostic checking System will perform a check on any unusual/error code from the memory To clear the stored in memory (EE
16、PROM IC) Self Diagnostic Mode Error code information Delete error code Step 1: Select CD mode (Ensure no disc is inserted). Step 2: Press & hold button follow by on main unit for 2 seconds. Step 1: In self diagnostic mode, Press on main unit. To exit, press /I on main unit or remote control. Step 1:
17、 In self diagnostic mode, Press 0 on remote control. To exit, press /I on main unit or remote control. Example: / Cold StartTo active cold start upon next AC power up when reset start is execute the next time. In self diagnostic mode: 1. Press 3 button on the remote control. 25 8.5.2.CD Mechanism Er
18、ror Code Table (CD Mechanism Unit) 8.6.Sales Demonstration Lock Function 8.6.1.Entering into Sales demonstration lock mode Here is the procedures to enter into the Sales demonstration lock mode. Step 1: Turn on the unit. Step 2: Select to any mode function. Step 3: Press and hold OPEN/CLOSE and CD k
19、eys for 5 sec or more. The display will show upon entering into this mode for 2 sec. Note: OPEN/CLOSE button is invalid and the main unit displays “LOCKED” while the lock function mode is entered. 8.6.2.Cancellation of Sales demonstration lock mode Step 1: Turn on the unit. Step 2: Select to any mod
20、e function. Step 3: Set volume to Vol 19. Step 4: Press and hold OPEN/CLOSE and CD keys for 5 sec or more. The display will show upon entering into this mode for 2 sec. Error CodeDiagnostic ContentsDescription of errorAutomatic FL DisplayRemarks CD H15CD Open AbnormalDuring operation POS_SW_R On fai
21、l to be detected with 4 sec. Error No. shall be clear by force or during cold start. Press on main unit for next error. CD H16CD Closing AbnormalDuring operation POS_SW_CEN On fail to be detected with 4 sec. Error No. shall be clear by force or during cold start. Press on main unit for next error. F