Marantz-SA-8004-Service-Manual(1) 电路图 维修手册.pdf
《Marantz-SA-8004-Service-Manual(1) 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SA-8004-Service-Manual(1) 电路图 维修手册.pdf(97页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service Manual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifi cations and design are subject to change without notice. Super Aud
2、io CD player SA8004 /K1SG/U1B SA-KI-PEARL-LITE /N1SG/N1B SA8004 SA-KI-PEARL-LITE SA8004 SA-KI-PEARL-LITE S0138-1V02DM/DG1009Copyright 2010 D press the 3 button, and the number goes down at 1% step. Press the 2 button at any value, and the setting for Open1 will be determined (between 0 and 500ms). O
3、nce the setting is determined, it will automatically determine the setting for Open2. Likewise, determine the setting for each of Open2 to Open5 and then for each of Close1 to Close5. When the Close5 setting is completed, the display will show the following message: Then, press the 2 button, and the
4、 OPEN/CLOSE operation will be repeated three times at the set speed. Meanwhile, press the 1 button while this message is on the display, and the OPEN/CLOSE test will be cancelled and the model indication will return to the display. However, the setting has been memorized so that the speed will remai
5、n unchanged. Also, press the 3 button while this message is on the display, and the OPEN/CLOSE test will be cancelled, the model indication will return and the setting will be cancelled. When the OPEN/CLOSE test is performed with the operation repeated three times, the display will show the followin
6、g message: Press the 2 button then, and the model identifi cation will return, and the OPEN/CLOSE will be performed at the set speed. If another button is pressed, the setting will be cancelled and the model identifi cation will return. Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA-
7、 B 1 S_T R A YP E E D = Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 _1O p e n_ X X X % _ Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 PST R Y _ T e s t ? Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 CPT R Y Sh a n g e ? 23 B The m
8、ode to check the last error message etc. This test mode is common to all models. 1. The error message displayed as the Last Error Message (1) Communication error between SA-CD Module and Microprocessor When having had the communication error with the SA-CD Module more than a regulated number of time
9、s, the unit will reset the SA-CD Module after displaying the following message. This will continue to be displayed until the unit has recovered from the communication error. When the unit is ready to play back CDs and SA-CDs, the SA-CD Module and the Microprocessor communicate regularly. Check the s
10、ignal in reference to the communication between the SA-CD Module and the Microprocessor on Communication Waveforms page. The MOD_SCL is the clock that is transmitted from the SA-CD regularly. If this signal cannot be detected, the SA-CD Module may be broken. If so, replace the SA-CD Module. When the
11、 SA-CD Module has been replaced, ensure that the Playtime will be cleared. (2) Communication Error between D/A Converter and Front Microprocessor If no response is detected in the communication between the D/A Converter and the Microprocessor, the display will show the following message. Make the CD
12、/SA-CD or the USB replayable. Ensure that IIC communications have been established between R217 and R218 when the unit is switched from STOP to PLAY. If the error cannot be corrected through normal operations, U204 may be broken. If such is the case, replace U204. 2. Error messages that are not disp
13、layed in the Last Error Message (1) Error messages that can be displayed on the FL (Communication Error between the Front Microprocessor and EEPROM) If no response is detected between the Front Microprocessor and EEPROM within a regulated timeframe, the display will show the following message. Ensur
14、e that IIC communications have been established between R123 and R125 when the unit is powered on or put into STANDBY. IF the error cannot be corrected through normal operations, U101 may be broke. If such is the case, replace U101. When no disc information is displayed 120 seconds after the disc is
15、 loaded, the display will show the following message. Reset the SA-CD Module. If no information can be obtained after this operation has been repeated three times, the unit will open the tray by itself. The unit cannot play back the disc if this message appears. Display Off RPTRNDMPROGTRKSA-CDCDM FI
16、LEUSBSTRGD OFF REMAINTTLA- B 1 C_S A C Do m _ E r r Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 rrD A C Eo r I I C _ Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 rEE R O Mr o r I I C Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 t_
17、 C a n_ P l a y _ 24 C Error Messages special to USB 1. Error Message displayed as the Last Error Message If no response is made in the communication between the USB Module U501 and the microprocessor within a designated timeframe, the display will show the following message. Refer to the Communicat
18、ion between USB Module and the microprocessor on the Communication Waveform page and check the signal. If the error message bellow cannot be cleared despite the unit performing normal operations properly, U501 may be broken. If such is the case, replace U501. If no response is made in the communicat
19、ion with an iPod-authenticated IC within a regulated timeframe, the display will show the following message. As the communication with the authenticated IC has not been established normally, ensure that the IIC signal is communicating at a normal level when the unit is connected with an iPod. The fr
20、equency of the IIC clock (IIC_SCL) is approximately 40 kHz only when the unit communicates with an iPod- authenticated IC. If no communication can be detected, check the soldering points of the microprocessor (U102), resistors (R155, R157) and the authenticated IC (U151). If the problem specifi c to
21、 the iPod cannot be rectifi ed, the authenticated IC (U151) may be broken. If that is the case, replace U151. When the iPod-authenticated IC has received error information, the display will show the following message. This message means that the authenticated IC is communicating properly. Try connec
22、ting another iPod. If no problem arises with another iPod, advise the user to repair the iPod. If the same problem arises with another iPod, the authenticated IC (U151) may be broken. If that is the case, replace U151. When a problem arises with the processing of the iPod authentication and signatur
23、e, the display will show the following message. If the following message appears instead of the above messages - iPodErrorIC”, iPodICErrorx and USB_Com_ Error_, try connecting another iPod. If no problem arises, advise the user to repair the iPod. If the error message persists, the authenticated IC
24、(U151) may be broken. If that is the case, replace U151. Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 oCU S B _m _ E r r _ Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B 1 rEi P o dr o r I I C Display Off RPTRNDMPROGTRKSA-CDCDM FILEUSBSTRGD OFF REMAINTTLA- B