1、 100 Corporate Drive Mahwah, NJ 07430 Service Bulletin No. : MZ10-020 Date: June 3, 2010 _ Model: UD9004 Subject: Correction of the firmware of DPMS Countermeasure is applicable only upon claim from the customer. Symptom: 1) The sound of analog-output is distorted and can not play normally when play
2、ing the multi channel of a specific BD disc titled 20th Anniversary DREAMS COME TRUE CONCERT TOUR 2009. 2) When BD software THE HAPPENING was reproduced, a menu screen does not output it after updating the unit for BD disc AVATAR. 3) We are modified unit by indication from the DVD Copy Control Assoc
3、iation (DVD CCA). Solution: We corrected the firmware so that no malfunction occurs. Please do not use a Proxy for updating in the Network environment! If customer uses setting of Proxy, the unit doesnt update the firmware properly. If the customer updated the firmware once via DPMS or CD-R, custome
4、r can update the firmware with Proxy in the Network environment. Caution: It is necessary to initialize the unit before the update work begins. The customer has to initialize their BD/DVD Player. Please update the firmware after you confirm this matter to the customer beforehand. Updating the firmwa
5、re Please refer to the Service manual. _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from di
6、sclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of
7、the information contained in this document. RadioFans.CN 收音机爱 好者资料库 METHOD OF UPDATE by CD-R with firmware We will supply the following program files for updating the subject models. Therefore, please record each program file on a blank CD-R separately, and update the unit upon claim. Caution: The u
8、pdate time might change depending on the situation of the DPMS server and the speed of the Internet environment of the customers house. Remark!: Recovery of the firmware when unit indicates NC Firm on the FL Display. If the FL Display shows NC Firm isnt turning into the following version of the firm
9、ware during the rewriting operation, wait longer than 10 minutes. Then, pull out the AC cable from AC socket in the wall, wait 10 seconds, and then insert AC cable to AC socket in the wall. The unit will start recovering the firmware of System micro processor. After that, please update the firmware
10、of unit via DPMS again. * Program Files to be supplied: Note: Upon recording the Disc: a) When recording the supplied file on the blank CD-R, the format shall be ISO9660 and the session shall be CLOSE. b) When recording the supplied file on the disc, please use the lowest recording speed that is ava
11、ilable on your PC. If the file is recorded at a higher speed, the rewriting operation may fail due to improperly recorded data on the disc. Rewriting procedures of the SYSTEM ROMs. (1) Download the 9004_SYS.ROM firmware in SDI. (2) Please make DM_FM_UP folder on PC. (3) Please insert the 9004_SYS.RO
12、M firmware into DM_FM_UP folder. Root - DM_FM_UP |_9004_SYS.ROM (4) Please burn the CD-R by at once mode. (5) Turn the Power Supply of the unit on. Press the OPEN/CLOSE button and open the Disc Tray. _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive u
13、se by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this d
14、ocument and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库 _ CONFIDENTIALITY NOTICE: The information contained in this document is
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Marantz-UD9004-sacd-mz10020 电路图 维修手册 Marantz UD9004 sacd mz10020 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf