Yamaha-RXV100D-avr-sm 电路图 维修手册.pdf
《Yamaha-RXV100D-avr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Yamaha-RXV100D-avr-sm 电路图 维修手册.pdf(74页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL 100986 IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the user
2、s, and have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA pro
3、duct owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any applicable technical
4、capabilities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications ar
5、e, therefore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body
6、 may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. I CONTENTS TO SERVICE PERSONNEL . 2 FRONT PANEL . 3 REA
7、R PANELS . 3 REMOTE CONTROL PANEL . 4 SPECIFICATIONS. 56 ADVANCED SETUP . 7 INTERNAL VIEW . 7 DISASSEMBLY PROCEDURES . 811 SELF DIAGNOSIS FUNCTION (DIAG) . 1230 AMP ADJUSTMENT . 31 IC DATA . 3235 BLOCK DIAGRAM. 3637 DISPLAY DATA . 38 PRINTED CIRCUIT BOARD . 3951 PIN CONNECTION DIAGRAM . 52 SCHEMATIC
8、 DIAGRAM . 5360 PARTS LIST. 6173 REMOTE CONTROL. 74 P.O.Box 1, Hamamatsu, Japan RX-V100D AV RECEIVER RX-V100D 2005 All rights reserved. This manual is copyrighted by YAMAHA and may not be copied or redistributed either in print or electronically without permission. 05.11 RadioFans.CN 收音机爱 好者资料库 RX-V
9、100D 2 RX-V100D WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUIVALENT INSULATING TABLE WARNING: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where applicable) components may also contain
10、traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA- SON WHATSOEVER! Avoid prolonged, unprotecte
11、d contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food. I TO SERVICE PERSONNEL 1. Critical Components I
12、nformation Components having special characteristics are marked s and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive s
13、urfaces are properly insulated from supply circuits. GMeter impedance should be equivalent to 1500 ohms shunted by 0.15F. GLeakage current must not exceed 0.5mA. GBe sure to test for leakage with the AC plug in both polarities. The P.C.B.s installed in this unit are soldered using the following sold
14、er. About Lead Free Solder Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag + Cu (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn + Bi (tin + zinc + bismuth) Caution: 1. As the melting point temperature o
15、f the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a soldering iron suitable to each solder. 2. If lead solder must be used, be sure to remove lead free solder from each terminal section of the parts to be replaced and from the area around it
16、completely before soldering, or make sure that the lead free solder and lead solder melt together fully. SIDE ASIDE B DSP P.C.B.Lead SolderLead Free Solder FUNCTION P.C.B.Lead Free Solder OPERATION P.C.B.Lead Free Solder MAIN P.C.B.Lead Free Solder POWER P.C.B.Lead Free Solder SUBTRANS P.C.B.Lead Fr
17、ee Solder DAB P.C.B.Lead Free Solder Side A Side B SMT REFLOW Process MI FLOW Process Solder Dip RadioFans.CN 收音机爱 好者资料库 RX-V100D 3 RX-V100D I FRONT PANEL B model I REAR PANELS G model B model RadioFans.CN 收音机爱 好者资料库 RX-V100D 4 RX-V100D I REMOTE CONTROL PANEL RAV306 5 RX-V100D I SPECIFICATIONS I Aud
18、io Section Minimum RMS Output Power (Power Amp. Section) (0.06 % THD, 8 ohms) FRONT L/R.85 W + 85 W CENTER . 85 W SURROUND L/R .85 W + 85 W SURROUND BACK . 85 W DIN Standard Output Power Per Channel (0.7 % THD, 4 ohms) MAIN L/R .130 W + 130 W CENTER . 130 W SURROUND L/R . 130 W + 130 W SURROUND BACK
19、 . 130 W IEC Power (0.06 % THD, 8 ohms) .95 W + 95 W Dynamic Power Per Channel (IHF) FRONT L/R (8 ohms/6 ohms/4 ohms/2 ohms) .115/150/185/230 W Damping Factor FRONT L/R (20 Hz to 20 kHz, SPEAKER-A) . 120 or more Input Sensitivity / Input Impedance CD, etc. . 200 mV / 47 k-ohms MULTI CH INPUT FRONT L
20、/R, CENTER, SURROUND L/R, SUBWOOFER . 200 mV / 47 k-ohms Maximum Input Signal (1 kHz, 0.5 % THD) CD, etc. (EFFECT ON) .2.2 V or more Output Level / Output Impedance REC OUT . 200 mV / 1.2 k-ohms SUBWOOFER (2ch Stereo ? etc. 3 DAB MENUA ) INIT SCANSCAN : FULLFULL / UK_BAND3 / NO B ) TUNE AID5A LEVEL
21、: XX5A LW (DAB Channel Label) C ) DRC MENUDRC MODE : AUTO AUTO / OFF D ) PRUNE LISTOK : ENTERYES / NO E ) PRESET DELETEDELETE : XXXX (Preset Number) 4 OPTION MENUA ) DISPLAY SETDIMMER : 0-5 to 0 / 1 step V CONV. : ONOFF / ON B ) MEMORY GUARDMEM. GUARD : OFFOFF / ON C ) PARAM. INI D ) MULTI ZONESP B
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha-RXV100D-avr-sm 电路图 维修手册 Yamaha RXV100D avr sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf