Yamaha-HTR-5890-Service-Manual 电路图 维修手册.pdf
《Yamaha-HTR-5890-Service-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Yamaha-HTR-5890-Service-Manual 电路图 维修手册.pdf(41页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL 100942 IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the user
2、s, and have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA pro
3、duct owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any applicable technical
4、capabilities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications ar
5、e, therefore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body
6、 may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. P.O.Box 1, Hamamatsu, Japan I CONTENTS TO SERVICE PERSO
7、NNEL . 2 FRONT PANEL . 3 REMOTE CONTROL PANEL . 3 REAR PANELS . 4 SPECIFICATIONS. 57 INTERNAL VIEW . 8 DISASSEMBLY PROCEDURES . 912 UPDATING FIRMWARE . 13 SELF DIAGNOSIS FUNCTION (DIAG) . 1432 AMP ADJUSTMENT . 33 DISPLAY DATA . 34 IC DATA . 3541 BLOCK DIAGRAM. 4243 PRINTED CIRCUIT BOARD . 4460 PIN C
8、ONNECTION DIAGRAM . 6162 SCHEMATIC DIAGRAM . 6371 PARTS LIST. 7390 REMOTE CONTROL. 91 Parts List for Carbon Resistors . 92 AV RECEIVER HTR-5890 HTR-5890 05.03 RadioFans.CN 收音机爱 好者资料库 HTR-5890 2 HTR-5890 WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUIVALENT INSULATING TABLE WARNING: CHEMIC
9、AL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause canc
10、er and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA- SON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux
11、vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food. I TO SERVICE PERSONNEL 1. Critical Components Information Components having special characteristics are marked s and must be replaced with parts having specific
12、ations equal to those originally installed. 2. Leakage Current Measurement (For 120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. GMeter impedance should be equivalent to 1500 ohms shunted b
13、y 0.15F. “CAUTION” “F1, F2: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 10A, 125V FUSE.” CAUTION F1, F2: REPLACE WITH SAME TYPE 10A, 125V FUSE. ATTENTION F1, F2: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 10A, 125V. GLeakage current must not exceed 0.5mA. GBe sure
14、 to test for leakage with the AC plug in both polarities. About Lead Free Solder The P.C.B.s installed in this unit are soldered using the following solder. Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag + Cu
15、 (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn + Bi (tin + zinc + bismuth) Side A Side B SMT REFLOW Process MI FLOW Process Solder Dip Caution: 1. As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a
16、soldering iron suitable to each solder. 2. If lead solder must be used, be sure to remove lead free solder from each terminal section of the parts to be replaced and from the area around it completely before soldering, or make sure that the lead free solder and lead solder melt together fully. DSP P
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha-HTR-5890-Service-Manual 电路图 维修手册 Yamaha HTR 5890 Service Manual 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


