Panasonic-SAMAX500LMK-cs-sm 电路图 维修手册.pdf
《Panasonic-SAMAX500LMK-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAMAX500LMK-cs-sm 电路图 维修手册.pdf(133页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2013. All rights reserved. Unauthorized copying and distribution is a violation of law. PMX1302001CE CD Stereo System Model No.SA-MAX500LMK Product Color: (K).Black Type TABLE OF CONTENTS 1 Safety Precautions 1.1. General Guidelines 1.3. Before Repair and Adjustment 1.4. Prote
2、ction Circuitry 1.5. Caution For Fuse Replacement 1.6. Safety Parts Information 2 Warning 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices 2.2. Precaution of Laser Diode 2.3. Service caution based on Legal restrictions 2.4. Handling Precautions for Travers
3、e Unit 2.5. Groundingforelectrostaticbreakdown prevention 3 Service Navigation 3.1. Service Information 3.2. Firmware Update Procedure 4 Specifications 5 General/Introduction 5.1. Media Information 6 Location of Controls and Components 6.1. Remote Control Key Button Operation 6.2. Main Unit Key Butt
4、on Operation 7 Installation Instructions 7.1. Speaker and A/C Connection 8 Service Mode 8.1. Cold-Start 8.2. Doctor Mode Table 8.3. Reliability Test Mode (CD Mechanism Unit) Please refer to the original service manual for: CD Mechanism Unit, Order No. PSG1201019AE Speaker system SB-MAX500LMK, Order
5、No. PMX1302002CE SB-MAX500 LSB-MAX500 R SA-MAX500 Nota: El idioma original de este Manual de Servicio es en idioma ingls, sin embargo algunas notasaqu mencionadas sern escritas en espaol para mejor descripcin para Centros de Servicio de Mxico. RadioFans.CN 收音机爱 好者资料库 8.4. Self-Diagnostic Mode 8.5. S
6、elf-Diagnostic Error Code Table 8.6. Sales Demonstration Lock Function 9 Troubleshooting Guide 10 Disassembly and Assembly Instructions 10.1. Screw Types 10.2. Disassembly Flow Chart 10.3. Main Components and P.C.B. Locations 10.4. Disassembly of Top Cabinet 10.5. Disassembly of Front Panel Unit 10.
7、6. Disassembly of FL Display P.C.B. 10.8. Disassembly of Control P.C.B. 10.10. Disassembly of Volume P.C.B. 10.11 Disassembly of Volume Jog Led 10.12. Disassembly of Remote Sensor P.C.B. 10.13. Disassembly of USB P.C.B. 10.14. Disassembly of Mic P.C.B. 10.16. Disassembly of CD Lid 10.17. Disassembly
8、 of Rear Panel 10.18. Disassembly of CD Mechanism Unit 10.19. Disassembly of Main P.C.B. 10.20. Disassembly of Digital Amplifier IC I 10.21. Disassembly of SMPS P.C.B. 10.22. Replacement of Switching Regulator (Q5700) 10.23. Replacement of Rectifier Diode (D5801) 10.24. Replacement of Rectifier Diod
9、e (D5802) 10.25. Disassembly of CD Interface P.C.B. 11 Service Position 11.1. Checking and Repairing of FL Display P.C.B., Control P.C.B., Volume P.C.B., Mic P.C.B. and USB P.C.B. 11.2. Checking and Repairing of Main P.C.B. (Side B) 11.3. Checking and Repairing of Main P.C.B. (Side A) 11.4. Checking
10、 and Repairing of SMPS P.C.B. 12 Block Diagram 12.1. Servo X: NG (In case that time out happens.) : Either one of FOAOC, TR AOC and FO coarse AGC is NG. : If theAGC is NG (ignore others). 2.To cancel, press 0 on remote control . 2.To cancel, press 0 on remote control . ROM Version (Display 1) (Displ
11、ay 2) Year Develop Year Develop ROM Type Version(Decimal) after 2 sec Version (Decimal )Checksum (Hex) 8.3.Reliability Test Mode (CD Mechanism Unit (BRS11C) Below is the process flow chart of the aging test for the CD Mechanism Unit (BRS11C). Fig. 1. Reliability Test (Loading) Fig. 2. Reliability Te
12、st (Traverse) Fig. 3. Reliability Test (Combination) OPEN Operation OPEN wait for 1 s CLOSE Operation CLOSE wait for 4 s Count up First Track Access First Track Play 5 s Last Track Access Last Track Play 5 s Count up First Track Access Access Play 10 s Open Operation Open wait for 1 s CLOSE Operatio
13、n Count up First Track Last Track Last Track Play 10 s 8.4.Self-Diagnostic Mode 8.5.Self-Diagnostic Error Code Table Self-Diagnostic Function (Refer Section 8.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and its respective components by displaying the error co
14、des. These error code such as U*, H* and F* are stored in memory and held unless it is cleared. The error code is automatically display after entering into self-diagnostic mode. 8.5.1.Power Supply Error Code Table FL Display Key Operation Front Key Item Description Mode Name To enter into self diagn
15、ostic check ing System will perform a check on any unusual/ error code from the memory To clear the stored in memory (EEPROM IC) Self Diagnostic Mode Error code information Delete error code Step 1: Select CD mode (Ensure no disc is inserted). Step 2: Press & hold button follow by on main unit for 2
16、 seconds. Step 1: In self diagnostic mode, Press on main unit. To ex it, press / I on main unit or remote control. Step 1: In self diagnostic mode, Press 0 on remote control. To ex it, press / I on main unit or remote control. Ex ample: / Cold StartTo activ e cold start upon nex t AC power up when r
17、eset start is ex ecute the nex t time. In self diagnostic mode: 1. Press 3 button on the remote control. 8.5.2.CD Mechanism Error Code Table (CD Mechanism Unit) 8.6.Sales Demonstration Lock Function 8.6.1.Entering into Sales demonstration lock mode Here is the procedures to enter into the Sales demo
18、nstration lock mode. Step 1: Turn on the unit. Step 2: Select to any mode function. Step 3: Press and hold OPEN/CLOSE and CD keys for 5 sec or more. The display will show upon entering into this mode for 2 sec. Note: OPEN/CLOSE button is invalid and the main unit displays “LOCKED” while the lock fun
19、ction mode is entered. 8.6.2.Cancellation of Sales demonstration lock mode Step 1: Turn on the unit. Step 2: Select to any mode function. Step 3: Set volume to Vol 19. Step 4: Press and hold OPEN/CLOSE and CD keys for 5 sec or more. The display will show upon entering into this mode for 2 sec. Error
20、 CodeDiagnostic ContentsDescription of errorAutomatic FL DisplayRemarks CD H15CD Open AbnormalDuring operation POS_SW_R On fail to be detected with 4 sec. Error No. shall be clear by force or during cold start. Press on main unit for next error. CD H16CD Closing AbnormalDuring operation POS_SW_CEN O
21、n fail to be detected with 4 sec. Error No. shall be clear by force or during cold start. Press on main unit for next error. F26Communication between CD servo LSI and micro-p abnormal. During switch to CD func- tion, if SENSE = “L” within failsafe time of 20ms. Press on main unit for next error. 9Tr
22、oubleshooting Guide 9.1.Part Location 9.1.1.SMPS P.C.B. Fig. 1 SMPS P.C.B. Thermistor : TH5861 Photocoupler : PC5720 AC Inlet : P5701 Fuse : F1 Photocoupler : PC5702, PC5799 Switching Regulator IC: IC5701 SMPS Control IC: IC5799 Main Transformer : T5701 Rectifier Diode : D5801, D5802 Connector: CN58
23、02 Sub Transformer : T5751 Sub Transformer : D5798 9.1.2.Main P.C.B. (Front Side) Fig. 2 Main P.C.B. (Front Side) Regulator Circuit IC2014 Fig. 3 Main P.C.B. (Back Side) 9.1.3.D-AMP P.C.B. Fig. 4 D-Amp P.C.B. Audio Digital Amp IC: IC5200 Audio Digital Amp IC: IC5000 Audio Digital Amp IC: IC5300 Audi
24、o Digital Amp IC: IC5400 Resistor DefectiveResistor Defective R5005 Resistor Defective R5004 Resistor Defective R5405 Resistor Defective R5402 R5201 Resistor Defective R5200 Resistor Defective R5010 Resistor Defective R5011 Resistor Defective R5411 Resistor Defective R5210 Resistor Defective R5211 R
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAMAX500LMK-cs-sm 电路图 维修手册 Panasonic SAMAX500LMK cs sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf