Panasonic-SAUX100-cs-sm1 电路图 维修手册.pdf
《Panasonic-SAUX100-cs-sm1 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAUX100-cs-sm1 电路图 维修手册.pdf(24页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Panasonic Corporation 2016. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1609001AE CD Stereo System Model No.SA-UX100E SA-UX100GN SA-UX100GS Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Notes - 3 2 Safety Precautions- 3 2.1. General Guidelines-
2、3 2.2. Before Repair and Adjustment- 4 2.3. Protection Circuitry- 5 2.4. Caution For AC Cord (For E/GS)- 6 2.5. Safety Parts Information - 7 3 Specifications - 8 4 Location of Controls and Components- 9 4.1. Remote Control Key Button Operation- 9 4.2. Main Unit Key Button Operation- 10 5 Disassembly
3、 and Assembly Instructions- 11 5.1. With reference to original service manual Section 8.9 “Disassembly of Rear Cabinet”, here is the change for this model - 11 6 Schematic Diagram - 13 6.1. Main (MICON) Circuit (1/2)- 13 6.2. Main (MICON) Circuit (2/2)- 14 6.3. Main (AUX Tuner) Circuit - 15 6.4. Mai
4、n (DAMP) Circuit - 16 Notes: Please use this manual together with service manual Model No.SA-AKX100PSK, Order no. (PSG1608001CE). CD Mechanism Unit (BRS12C) , Order No. PSG1303059AE Speaker system SB-UX100GN-K, Order No: PSG1609002AE RadioFans.CN 收音机爱 好者资料库 2 6.5. Main (Voltage Regulator) Circuit -1
5、7 7 Printed Circuit Board -18 7.1. Main P.C.B. -18 8 Exploded View and Replacement Parts List -19 8.1. Cabinet Parts Location 1-19 8.2. Packaging-20 8.3. Mechanical Replacement Part List -21 8.4. Electrical Replacement Part List -23 RadioFans.CN 收音机爱 好者资料库 3 1Notes This simplified service manual is
6、base on SA-AKX100PS (Order No. PSG1608001CE). 1) This service manual contains only following information - Safety Precautions - Specifications - Locations of Controls and Components - Disassembly and Assembly Instructions - Location of Rear Shield - Schematic Diagram - Main (MICON) Circuit - Main (A
7、ux Tuner) Circuit - Main (DAMP) Circuit - Main (Voltage Regulator) Circuit - Printed Circuit Board - Main P.C.B. - Exploded View and Replacement Parts List 2Safety Precautions 2.1.General Guidelines 1. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important fo
8、r safety. These parts are marked by in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modify the ori
9、ginal design without permission of manufacturer. 2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal
10、injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during servicing. 3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 4.
11、After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards. 2.1.1.Leakage Current Cold Check 1. Unp
12、lug the AC cord and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a r
13、eturn path to the chassis, the reading should be between 1M and 5.2M. When the exposed metal does not have a return path to the chassis, the reading must be RadioFans.CN 收音机爱 好者资料库 4 2.1.2.Leakage Current Hot Check 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer
14、for this check. 2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1-1. 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential acr
15、oss the resistor. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent)
16、may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer. Figure 1-1 2.2.Before Repair
17、 and Adjustment Disconnect AC power to discharge AC capacitor (in SMPS Module) as indicate below diagram through a 10 , 10 W resistor to ground. Figure 1-2 Caution: DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices. After repairs are comp
18、leted, restore power gradually using a variac to avoid overcurrent. Current consumption at AC 220240 V, 50 Hz in Power ON, FM Tuner at volume minimal mode should be 350 mA (For E/GN). Current consumption at AC 220240 V, 50/60 Hz in Power ON, FM Tuner at volume minimal mode should be 350 mA (For GS).
19、 5 2.3.Protection Circuitry The protection circuitry may have operated if either of the following conditions are noticed: No sound is heard when the power is turned on. Sound stops during a performance. The function of this circuitry is to prevent circuitry damage if, for example, the positive and n
20、egative speaker connection wires are “shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used. If this occurs, follow the procedure outlines below: 1. Turn off the power. 2. Determine the cause of the problem and correct it. 3. Turn on the
21、power once again after one minute. Note: When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again. 6 2.4.Caution For AC Cord (For E/GS) Figure 1-3 7 2.5.Safety Parts Information Safety Parts List: There are special components used in t
22、his equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Exploded View & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent shock, fire or other hazards. Do not modify the origin
23、al design without permission of manufacturer. SafetyRef No.Part No.Part Name & DescriptionRemarks 7TKFA22101TOP CABINET 11TBMK4271BNAME PLATEGN 11TBMK4271CNAME PLATEGS 11TBMK4271DNAME PLATEE 301TXQ0011TRAVERSE ASSY(E.S.D) A2K2CJ2YY00101AC CORDGN A2K2CP2YY00061AC CORDGS A2K2CQ2YY00119AC CORDE,GS A2K2
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAUX100-cs-sm1 电路图 维修手册 Panasonic SAUX100 cs sm1 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf