Panasonic-SAEH790E-rec-sm 电路图 维修手册.pdf
《Panasonic-SAEH790E-rec-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAEH790E-rec-sm 电路图 维修手册.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO.AD0303004C2 Tuner/Amplifier SA-EH790E / SA-EH790EB / SA-EH790EG / SA-EH790EP Colour (S).Silver Type System: SC-EH790 Because of unique interconnecting cables, when a compact requires service, send or bring in the entire system. SPECIFICATIONS Specification 1 RadioFans.CN 收音机爱 好者资料库 Amplifie
2、r section Power output (L/R both channel driven) Stereo Mode DIN1 kHz THD 1%/6 (High)225 W 100 Hz THD 1%/8 (Low)245 W RMS1 kHz THD 10%/6 (High)235 W 100 Hz THD 10%/8 (Low)265 W PRO LOGIC mode DINFRONT 1 kHz THD 1%/6 (High)225 W 100 Hz THD 1%/8 (Low)245 W SURROUND 1 kHz THD 1%/8 230 W CENTER 1 kHz TH
3、D 1%/8 60 W RMSFRONT 1 kHz THD 10%/6 (High)235 W 100 Hz THD 10%/8 (Low)265 W SURROUND 1 kHz THD 10%/8 240 W CENTER 1 kHz THD 10%/8 80 W PMPO 1 kHz/High 6 , Low 8 , CENT. 8 , SURR. 8 3000 W Total harmonic distortion Rated power at 1 kHz1% (6 ) Half power at 1 kHz0.1% (6 ) Load impedance FRONT (High)6
4、 FRONT (Low)8 SURROUND8 CENTER8 DIGITAL S. WOOFER Center frequency60 Hz LEVEL (VOL -20 db)MID +3 db MAX +6 db FM tuner section Frequency range87.50108.00 MHz (0.05 MHz steps) Sensitivity 1.8 V (IHF usable) S/N 26 db 1.5 V S/N MONO70 db (75 db, IHF) Antenna terminal(s)75 (unbalanced) AM tuner section
5、 Frequency range5221629 kHz (9 kHz steps) 5201630 (10 kHz steps) Sensitivity (S/N 20 db) 500 V/m Timer section ClockQuartz-lock type FunctionPlay timer (1 time, daily), Rec timer (1 time, daily) 2 RadioFans.CN 收音机爱 好者资料库 Sleep (120 min, 30 min intervals) Setting intervals (Play/Rec)1 minute23 hours
6、59 minutes (1 min intervals) General Power supply (For (E) ,(EG),(EP)areas)AC 230V 50Hz (For (EB) area)AC 230240V 50Hz Power consumption190 W Standby0.5 W Dimensions (WHD)293118.5345 mm Mass5.2 kg Nots1.Design and specifications are subject to change without notice. 2.Dimensions and mass are approxi
7、mate. 3.Total harmonic distortion is measured by the digital spectrum analyzer. System/SC-EH790 Sound processor: SH-EH790, CD changer: SL- EH790, Tuner/ Amplifier: SA-EH790 , Cassette Deck: RS-DV290, Speakers: Front* (SB-DV290), Center* (SB-PC95),Surround* (SB-PS95)(*Made in MAES.) 2003 Matsushita E
8、lectric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. 1. Before Repairs 1. Turn off the power supply. Using a 10 , 10 W resistor, connect both ends of power supply capacitors (C701, C703 and C702, C704) in order to discharge the voltage. 2. Be
9、fore turning the power supply on, after completion of repair, slowly apply the primary voltage by using a power supply voltage controller to make sure that the consumed current at 50 Hz in NO SIGNAL mode should be shown below with respecttosupply voltage 230/240 V. 3 RadioFans.CN 收音机爱 好者资料库 Power su
10、pply voltage AC 230 VAC 240 V Consumed current 50 Hz 100 - 350 mA 2. Protection Circuitry The protection circuitry may have operated if either of the following conditions is noticed: - No sound is heard when the power is switched ON. - Sound stops during a performance. The functions of this circuitr
11、y is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are shorted, or if speaker systems with an impedance less than the indicated rated impedance of this unit are used. If this occurs, follow the procedures outlined below. 1. Switch OFF the power. 2. D
12、etermine the cause of the problem and correct it. 3. Switch ON the power once again. Note: When the protection circuitry functions, the unit will not operate unless the power is first switched OFF and then ON again. 3. Accessories - AC mains lead for (E),(EG) and (EP) areas (RJA0019-2X).1 pc. - AC m
13、ains lead for (EB) area (RJA0053-3X).1 pc. 4 - Remote control (EUR7702270).1 pc. - Remote control batteries (R6/LR6,”AA”,UM-3).1 pc. Note: These are available on sales route. - FM indoor antenna (RSA0007).1 pc. - AM loop antenna set (RSA0022-L).1 pc. - Speaker leads 5 (REE1234-1).2 pc. (Red/Black) (
14、REE1233-1).2 pc. (Gray/Blue) - Antenna plug adaptor for (EB) area (SJP9009).1 pc. 4. Caution for AC Mains Lead 6 5. Location of Controls 6. Operation Checks and Component Replacement / Procedures - This section describes procedures for checking the operation of the major printed circuit boards and r
15、eplacing the main components. - For reassembly after operation checks or replacement, reverse the respective procedures. Special reassembly procedures are 7 described only when required. 6.1. Checking for the AC IN P.C.B. - Check the AC IN P.C.B. as shown below. 6.2. Checking for the operation P.C.B
16、. - Follow the (Step 1) - (Step 3) of item 6.1. 8 - Check the operation P.C.B. as shown below. 6.3. Checking for the main P.C.B. - Follow the (Step 1) - (Step 3) of item 6.1. 9 10 - Check the main P.C.B. as shown below. 6.4. Replacement for the regulator transistor - Follow the (Step 1) - (Step 3) o
17、f item 6.1. 11 6.5. Replacement for the power IC - Follow the (Step 1) - (Step 3) of item 6.1. - Follow the (Step 1) - (Step 6) of item 6.2. - Follow the (Step 1) - (Step 10) of item 6.3. 7. To Supply Power Source This unit is designed to operate on power supplied from system connected. / For system
18、 connection, refer to Fig. 7-1. Fig. 7-1. 12 When the unit has to test and service alone, use the following method to supply power source. 1. Short the section between W902A Pin 3 and C740 (-) (GND). (Refer to Fig. 7-2. ) 2. Connect this unit to an AC power supply cord. / (This unit come to stand-by
19、 mode.) 3. Turn the unit ON. Fig. 7-2. Notes: Use only this method when checking the voltage etc. / In case of checking the operations, use the system connections to supply power source. 8. Self-Diagnostic Function This unit is equipped with a self-diagnostic function which, in the event of a malfun
20、ction, 13 automatically displays a code indicating the nature of the malfunction. Use this self-diagnostic function when servicing the unit. 8.1. To display the malfunction code U70 CD: / U70 DECK: Automatically displays on the tuner/amplifier when a malfunction occurs. Refer to Fig. 8-1. F61: Autom
21、atically displays on the tuner/amplifier when a malfunction occurs. Refer to Fig. 8-1. Fig. 8-1. 8.2. To return to the normal display 1. For U70 CD/U70 DECK - Press an any operation button on the tuner/amplifier. - To re-display the code, switch the power off (POWER STANDBY button), and then switch
22、power back on again. 2. For F61 - If F61 is displayed, the power will automatically be switched off and the standby indicator will light up. - F61 will be displayed for 3 seconds, and then the clock will be displayed. 14 - To re-display the code, switch the power on. F61 will be re- displayed, and t
23、hen after 3 seconds the clock will be displayed and the power will automatically switch off. 8.3. Display contents 8.3.1. U70 CD/U70 DECK / (displayed automatically) - Problem or condition A bus-line communications error has occurred as a result of the flat cables being inserted incorrectly, thus pr
24、eventing the system from operating. - If U70 is displayed on the tuner/amplifier, the tape deck or CD Changer cannot be operated by remote control. - Correction Procedure 1. To check for correct insertion of flat cables. - Insert each connectors until you hear a click. - Insert the flat cables at th