Jvc-HXGX-7-Service-Manual 电路图 维修手册.pdf
《Jvc-HXGX-7-Service-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Jvc-HXGX-7-Service-Manual 电路图 维修手册.pdf(50页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITED No.MB161 2004/3 COMPACT COMPONENT SYSTEM MB16120043 HX-GX7 TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2、 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
3、7 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . 1-41 Area suffix J - U.S.A. C - Canada CA-HXGX7SP-HXGX7SP-HXGX7 RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB161) SPECIFICATION Design and specifications are subject to change without notice. Amplifier section-CA-HXGX7 Output Power SUBWOOFERS180 W per channel, min. RMS, driven into 6 at 63 Hz with no m
5、ore than 10 %total harmonic distortion. MAIN SPEAKERS80 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 10 %total harmonic distortion. Audio input sensitivity/impedance (Measured at 1 kHz, with tape recording signal 300 mV) AUX300 mV/47 k Speakers/impedanceSUBWOOFERS6 - 16 MAIN SPE
6、AKERS 6 - 16 Tuner FM tuning range87.5 MHz - 108.0 MHz AM tuning range530 kHz - 1 710 kHz CD player CD capacity5 discs Dynamic range87 dB Signal-to-noise ratio90 dB Wow and flutterImmeasurable MP3 recording formatMPEG 1/2 Audio Layer 3 Max. Bit rate320 kbps Cassette deck Frequency responseNormal (ty
7、pe I)50 Hz - 14 000 Hz Wow and flutter0.15 % (WRMS) General Power requirementAC 120 V , 60 Hz Power consumption245 W/310 VA (at operation) 26 W (on standby) Dimensions (approx.)205 mm 370 mm 432 mm (W/H/D) (8 1/8 in. 14 5/8 in. 17 1/0 16 in.) Mass (approx.)10.5 kg (23.2 lbs) Speaker section-SP-HXGX7
8、 Type3-Way 4-Speaker Bass-Reflex Type Speaker SystemsSubwoofer16 cm (6 5/16 in.) cone 1 Woofer12 cm (4 3/4 in.) cone 2 Tweeter5 cm (2 in.) cone 1 Power handling capacity Subwoofer360 (180 + 180) W Main speaker160 (80 + 80) W ImpedanceSubwoofer6 Main speaker6 Frequency rangeSubwoofer27 Hz - 1000 Hz M
9、ain speaker70 Hz - 25 000 Hz Sound pressure levelSubwoofer78 dB/Wm Main speaker88 dB/Wm Dimensions (approx.)227 mm 432 mm 376 mm (W/H/D) (8 15/16 in. 17 1/16 in. 14 13/16 in.) Mass (approx.)8 kg (17.7 lbs) each RadioFans.CN 收音机爱 好者资料库 (No.MB161)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This
10、 design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the or
11、iginal circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will furth
12、er relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection a
13、fforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by sha
14、ding on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads
15、in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should
16、 be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw head
17、s, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each ex
18、posed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,
19、000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed
20、 metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1
21、.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essent
22、ial that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre- forming rep
23、air of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for saf
24、ety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Jvc-HXGX-7-Service-Manual 电路图 维修手册 Jvc HXGX Service Manual 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


