1、n Amplifier Section RMS OUTPUT POWER both channel driven simultaneously 10% Total harmonic distortion80 W per channel (4 ) Input Impedance MUSIC PORT250 mV 13 k Output Impedance HEADPHONE16 to 32 Phone jack TerminalStereo, 3.5 mm Music port input jack TerminalStereo, 3.5 mm n FM Tuner Section Freque
2、ncy range87.50 MHz to 108.00 MHz (50 kHz steps) Sensitivity2.5 V (IHF) S/N 26dB1.4 V Antenna terminal(s)75 (unbalanced) Preset stationFM 15 stations AM 15 stations n AM Tuner Section Frequency range522 to 1629 kHz (9kHz steps) 520 to 1630 kHz (10kHz steps) Sensitivity S/N 20 dB (at 999 kHz)1584 V/m
3、n Cassette Deck Section Track system4-track, 2-channel 2006 Matsushita Electric Industrial Co. Ltd. All rightsreserved.Unauthorizedcopyingand distribution is a violation of law. SA-PMX1E SA-PMX1EB SA-PMX1EG Colour (S). Silver Type Heads Record/playbackSolid permalloy head ErasureDouble gap ferrite h
4、ead MotorDC servo motor Recording systemAC bias 100 kHz Erase systemAC erase 100 kHz Tape speed4.8 cm/s Overall frequency response (+3, -6 dB) at DECK OUT NORMAL35 Hz to 14 kHz S/N RATIO47 dB (A weighted) Wow and flutter0.08% (WRMS) Fast forward and rewind timeApprox. 120 seconds with C-60 cassette
5、tape n CD Section Disc played 8 cm or 12 cm (1) CD-Audio (CD-DA) (2) CD-R/RW (CD-DA, MP3 formatted disc) (3) MP3 Sampling frequency CD44.1 kHz MP332 kHz, 44.1 kHz, 48 kHz Bit rate MP332 kbps to 384 kbps Decoding16/20/24 bit linear Pickup Beam sourceSemiconductor laser Wavelength785 nm CD Stereo Syst
6、em Specification ORDER NO. MD0605198CE RadioFans.CN 收音机爱 好者资料库 Laser powerCLASS 1 Audio output (Disc) Number of channels2 Channel Frequency response20 Hz to 20 kHz (+1, -2 dB) Wow and flutterBelow measurable limit Digital filter8 fs D/A converterMASH (1 bit DAC) n General Power supplyAC 230 V, 50 Hz
7、 (For E, EG) AC 230 to 240 V, 50 Hz (For EB) Power consumption80 W Dimensions (W x H x D)174 mm x 242 mm x 318 mm Mass4.9 kg Operating temperature range+5C to +35C 1 Safety Precautions 4 1.1. GENERAL GUIDELINES 4 1.2. Caution for AC Cord 5 1.3. Before Repair and Adjustment 6 1.4. Protection Circuitr
8、y 6 2 Prevention of Electro Static Discharge (ESD) to Electrostatically Sensitive (ES) Devices 7 3 Precaution of Laser Diode 8 4 Handling Precautions For Traverse Deck 9 5 Handling the Lead free Solder 10 5.1. General description about Lead Free Solder (PbF) 10 6 Accessories 11 7 Operating Instructi
9、ons Procedures 12 7.1. Main Unit stop the aging test at CLOSE condition. 2. During CLOSE operation, after certain timing, the CD does not in CLOSE position. (After CLOSE operation, REST SW was not off in 4s.) Do the OPEN operation; stop the aging test at OPEN condition. Note : When key 0 is pressed,
10、 the current test shall be cancelled and returns to Doctor mode display. The count value shall be reset to (00000). During this test, FL shall display as normal and nodisplay on the FL. 8.1.5. CD Reliability Test (Traverse) Purpose : CD Access Inner and Outer Disc aging test. (Mainly used for CR130
11、unit reliability test). Below is the procedures for this mode. Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode). Step 2 : Switch to CD mode and when the key 12 are being pressed using the remote control, the following operation shall
12、 carried out : 19 SA-PMX1E / SA-PMX1EB / SA-PMX1EG Step 3 : Due to certain reasons, when the following condition happens, the aging will stop but the count value shall be maintained : After 10s, the Disc Access not yet completes. Out of Focus for more than 2s. Note : When key 0 is pressed, the curre
13、nt test shall be cancelled and returns to Doctor mode display. The count value shall be reset to (00000). During this test, FL shall display as normal and nodisplay on the FL. 8.1.6. CD Reliability Test (Combination) Purpose : This test is the combination of the OPEN/CLOSE operation and the Inner an
14、d Outer Disc Access operation aging test. (Mainly used for CR130 unit reliability test). Below is the procedures for this mode. Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode). Step 2 : Switch to CD mode and when the key 13 are bein
15、g pressed using the remote control, the following operation shall carried out : 20 SA-PMX1E / SA-PMX1EB / SA-PMX1EG Step 3 : Due to certain reasons, when the following condition happens, the aging will stop but the count value shall be maintained : During OPEN operation, after certain timing, the CD
16、 does not in OPEN position.(After REST SW is OFF, the CD OPEN SW did not ON after 4s.) During CLOSE operation, after certain timing, the CD does not in CLOSE position.(After CLOSE operation, REST SW was not off in 4s.) After 10s, the Disc Access not yet completes Out of Focus for more than 2s Note :
17、 When key 0 is pressed, the current test shall be cancelled and returns to Doctor mode display. The count value shall be reset to (00000). During this test, FL shall display as normal and nodisplay on the FL. 8.1.7. CD Self-Adjustment (AJST) Result Display Purpose : To display result of self-adjustm
18、ent for CD. Below is the procedures for this mode. Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode). Step 2 : When 14 key are pressed at the doctor mode, the following shall be displayed for 3 secs. The result shall correspond to the
19、 condition met as shown in the table below : 21 SA-PMX1E / SA-PMX1EB / SA-PMX1EG 8.1.8. TPS Inspection Purpose : Tape for TPS is put into Deck. TPS inspection starts with one key operation. This mode shall run a test program to check REV TPS for the Deck and ends by displaying the result and ejectin
20、g the Deck. Below is the procedures for this mode. Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode). Step 2 : Press button on remote control. Enter into TPS Test mode. (During this mode) Software will start checking for existence of
21、cassette in Deck. If the Deck does not contain any cassette, it shall end the test and displays EEROR. If the cassette is detected, test shall start by playing the DECK in reverse direction for 1 sec and perform REV TPS. If TPS signal is OK, the Deck shall be ejected. Below is information on the TPS
22、 under 3 examples. 1. If ERROR Flag is set ERROR shall be displayed. TPS check result shall not be shown in this case. 2. If Deck TPS check = OK 3. If Deck TPS check = NG 22 SA-PMX1E / SA-PMX1EB / SA-PMX1EG 8.1.9. MP3 Test Purpose : To check the MP3 Test. Below is the procedures for this mode. Step
23、1 : Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode). Step 2 : Press PROGRAM button on remote control. Execute MP3 Disc Check (Refer Flowchart below) 23 SA-PMX1E / SA-PMX1EB / SA-PMX1EG Result display : Displayed if MP3 test OK Displayed if
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAPMX1E-cs-sm 电路图 维修手册 Panasonic SAPMX1E cs sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf