Hafler-SE120-pwr-sm 电路图 维修手册.pdf
《Hafler-SE120-pwr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Hafler-SE120-pwr-sm 电路图 维修手册.pdf(13页珍藏版)》请在收音机爱好者资料库上搜索。
1、THE Hafler SE120 POWER AMPLIFIER SERVICE MANUAL HAFLER A DIVISION OF ROCKFORD CORPORATlON 613 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 RadioFans.CN 收音机爱 好者资料库 POWER AMPLIFIER SPECIFICATIONS POWER RATING: Less than 0.006% total harmonic distortion at any power level up to 60 watts continuous average
2、 power per channel into 8 ohms at any frequency between 20 Hz and 20 kHz with both channels driven. IM DISTORTION (IHF): Less than 0.005% from 1 to 60 watts, each channel, into 8 ohms. TYPICAL THD AT 60 WATTS INTO 8 OHMS: 20 Hz: 0.002% 1 kHz: 0.002% 20 kHz: 0.006% FREQUENCY RESPONSE INTO 8 OHMS: -3d
3、B, 4Hz to 2OOkHz at 1 watt. +OdB, -0.5dB, 1OHz to 4OkHz at 60 watts. TYPICAL CHANNEL SEPARATION: 2OHz: 75dB 1kHz: 85 dB 20kHz: 65dB SIGNAL TO NOISE RATIO, UNWEIGHTED: Exceeds 1OOdB referred to 60 watts into 8 ohms. INPUT IMPEDANCE: 22,000 ohms INPUT SENSITIVITY: 1.1 volts rms for 60 watts into 8 ohm
4、s. DAMPING FACTOR: 100to1kHzinto8ohms,50to1OkHzinto8ohms. POWER CONSUMPTION: 60 watts both channels into 8 ohms: 300 VA Quiescent: 60 VA SIZE: 3-1/4” high plus 1/2” feet, 17” wide, 9” deep. (83 mm high plus 152 mm, 432 mm wide, 229 mm deep.) NET WEIGHT: 18 lbs. (8.2 kg) SHIPPING WEIGHT: 20 lbs. (9.1
5、 kg) Stereo/Mono Channel Operation: The SE120 delivers 60 watts continuous average power per channel into 8 ohms. It can be bridged for single channel operation producing up to 120 watts of power into 16 ohms. Input Mode Selector: This switch will allow the user to specify the input signal to the am
6、plifier. A. Stereo Mode: This allows the right and left channels to reach their designated amplifier channels. This mode will deliver more than 60 watts into an 8 ohm load. B. Mono Mode: The SE1 20 can be operated in a bridged mode which drives both channels with the same signal and combines to deli
7、ver more than 150 watts into 8 ohms. This disables the right channel input and routes the signal through the left channel. Construction: The simplified construction of the SE120 improves relia- bility and results in consistent performance. The heavy duty case construction on the SE120 will provide y
8、ears of durability and trouble free protection. Gold Plated RCA Input Connectors: This provides the most accurate signal transmission and lowest possible loss. Gold-plated terminals are immune to signal deterioration with time that can be caused by corro- sion in the connectors. Speaker Output and P
9、ower Connectors: For minimum loss power transfer, high definition and oxidization resistance. Protection System: The SE120 is equipped with a unique protection system that constantly monitors the temperature of the output devices and takes corrective action to prevent damage to the amplifier as a re
10、sult of excessive overheating. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Copyright 1990. All rights reserved -l- RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 LINE CONNECTIONS AND SWITCHING The SE120 is normally wired for use on 12OV AC power lines, as in the U.S.A. If your line voltage
11、 is different, you will need the special Hafler export power transformer which accommodates many other line voltages. Be sure your amplifier is wired for your line voltage before you plug it in. The SEl2Os power switch may be left on, and the amplifier switched remotely by connecting its line cord t
12、o the preamplifier (or other control center) which provides a switched AC outlet. Make sure that the control device can supply a current of 5 amperes to the SE 120, in addition to the current required by any other switched units. You may instead connect the amplifier directly to a wall outlet, and c
13、ontrol it with its own front panel power switch. CONNECTING CABLES GROUNDING: INPUT: Conventional shielded cables, often supplied with pre- amplifiers, may connect the control center to the amplifiers input jacks. Be sure the cables are not frayed or loosely connected to the plugs, and that the plug
14、s outer shield connection is tight on the jack, to avoid hum. If you wish to install the SE120 more than a few feet from the preampli- fier, the permissible cable length to avoid loss of high frequencies is determined by the preamplifiers output im- pedance and the internal capacitance of the cable.
15、 If the output impedance is 600 ohms or less, as with Hafler preamplifiers, and the cable capacitance is less than 50 picofarads per foot, up to 50- feet is acceptable. Ordinary stereo interconnecting cables often have higher capaci- tance, however, so a good quality low capacitance shielded wire sh
16、ould be used. When making long runs, keep the left and right cables close together, and avoid running them parallel to power wiring to reduce the likelihood of hum pickup. OUTPUT: The wires which connect the speakers to the amplifier should be of sufficient size to preserve the SEl2Os high damping f
17、actor. Standard #18 gauge lamp cord is satisfac- tory for up to 15 feet if your speakers are of 8 ohms or higher impedance. A heavier gauge (#16 or larger) wire should be used with 4 ohm speakers or 8 ohm speakers at a greater distance. Special loudspeaker cables which have adequate thickness to acc
18、ommodate long runs are usually available from audio dealers. The SEl2Os red and black outputs accept standard banana plug connectors, including the double ones with 3/4” spacing. These are the most conven- ient to use if you will be disconnecting the speakers occa- sionally. The terminals will also
19、clamp a spade lug, or a bare wire through the hole in the center post. Be sure there are no frayed wire ends which could touch adjacent terminals or the chassis. Tin bare wire ends with solder to secure all strands. PHASING: Consistent phase relationships are important when con- necting speakers in
20、order to enable full bass reproduction as well as midrange and high frequency time alignment. To be sure all speakers in a system are wired in phase to the amplifier, each ground or - speaker terminal should be connected to its black ground tenninal on the SE 120 and the speakers + terminal to the c
21、orresponding red binding post. Speaker connecting cable identifies one wire from the other by the color of the wire, or by marking or coloring the insulation. NOTE: In the special case of monophonic operation of the SE 120, (described later) different speaker connections are employed. The black outp
22、ut terminals of the SE120 are connected together internally and grounded to the chassis. This facilitates the use of external devices which use a common ground connection, such as some headphone junctionboxes. You must be sure that the ground or shield connection from such a device goes to a black t
23、erminal on the SE1 20. NOTE: No such connection may be made when the SE120 is connected for bridged mono operation. CONVENTIONAL STEREO CONNECTIONS It is best to make all connections with the SE120 switched off. Each of the stereo speakers connects to one horizontal pair of red and black outputs, as
24、 identified left or right on back of the SE 120. The input signals connect to the corresponding input jacks, and the mono/stereo switch should be set to stereo. CONNECTIONS FOR MONOPHONIC OPERATION When you wish to drive a single loudspeaker with increased power capability, the SE120 can be operated