DENON avrx1600h 维修电路原理图.pdf
《DENON avrx1600h 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《DENON avrx1600h 维修电路原理图.pdf(161页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service Manual INTEGRATED NETWORK AV RECEIVER AVR-X1600H AVR-S750H Click here! On-line service parts list AVR-X1600H: AVR-S750H: ONLINE PARTS LIST (P5) WEB owners manual NA: EU: AP: JP: NA: EU: Upload is planned for the time of a future press release. BEFORE SERVICING THIS UNIT ELECTRICAL MECHANICAL
2、 REPAIR INFORMATION UPDATING Ver. 1 Confidential Forpurposesofimprovement,specificationsanddesignaresubjecttochangewithoutnotice. Please use this service manual whenreferringtotheoperatinginstructionswithoutfail. Some illustrations usedinthisservicemanualareslightlydifferentfromtheactualproduct. 收音机
3、爱 好者资料库 RadioFans.CN BEFORE SERVICING THIS UNIT SAFETY PRECAUTIONS NOTE FOR SCHEMATIC DIAGRAM HANDLING THE SEMICONDUCTOR AND OPTICS ONLINE PARTS LIST Accessing the Parts List Searching Part Numbers or Ref. Numbers NOTE FOR PARTS LIST SERIAL NUMBER Serial Number Organization SKU Code of this Unit POS
4、T-SERVICE PRECAUTIONS Initializing this Unit AVR-X1600H JIG FOR SERVICING Initializing this Unit AVR-S750H JIG FOR SERVICING Before Servicing This Unit ElectricalMechanicalRepair InformationUpdating 2 收音机爱 好者资料库 RadioFans.CN The following items should be checked for continued protection of the custo
5、mer and the service technician. Leakage current check Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chas- sis to either side of the p
6、ower cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable. CAUTION Please heed the following cautions and instructions during servic- ing
7、 and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) An AC voltage is im
8、pressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, f
9、or example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fin
10、gers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same proper
11、ties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! For safety seasons, some parts use tapes, tubes or other insul
12、ating materials, and some parts are mount- ed away from the surface of printed circuit boards. Care should also be taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally pl
13、aced. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorated the area around. Then make an insulation check on the external metal connectors and
14、between the blades of the power plug. And otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value bet
15、ween the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structural parts used in the set have special safety properties. In most cases th
16、ese properties are difficult to distinguish by sight, and the use of replacement parts with higher rat- ings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams
17、and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams Indicated by the z mark. (2) Parts lists Indicated by the z mark. The use of parts other than the designated parts could cause electric shocks, fires or oth
18、er dangerous situations. CAUTION Concerning important safety parts SAFETY PRECAUTIONS Before Servicing This Unit ElectricalMechanicalRepair InformationUpdating 3 收音机爱 好者资料库 RadioFans.CN WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by th
19、e manufacturer. CAUTION: Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohm
20、s, the set is defective. WARNING: DO NOT return the set to the customer unless the problem is identified and remedied. NOTICE: (1) ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM (2) ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO
21、FARAD. N INDICATES NANO FARAD. (3) EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. (4) CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential differ- ence caused by electrostatic
22、charge during unpacking or repair work. 1. Ground for Human Body Be sure to wear a grounding band (1 M ohm) that is properly grounded to remove any static electricity that may be charged on the body. 2. Ground for Workbench Be sure to place a conductive sheet or copper plate with proper grounding (1
23、 M ohm) on the work- bench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing CBA Grounding Band Conductive Sheet or Copper
24、Plate 1M 1M CBA NOTE FOR SCHEMATIC DIAGRAM HANDLING THE SEMICONDUCTOR AND OPTICS Before Servicing This Unit ElectricalMechanicalRepair InformationUpdating 4 ONLINE PARTS LIST Accessing the Parts List (1) Access from the Service Manual Click the URL link on the cover of the service manual. Examples o
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DENON avrx1600h 维修电路原理图 维修 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。