1、收音机爱 好者资料库 RadioFans.CN MANUAL OF 1939 MOST POPULAR SERVICE DIAGRAMS Automatic Record Chairfcr GENERAL INFORMATION , . Before servicing the automatic record changer, inspect the assembly to see that all levers, parts, gears, springs, etc. are in good order and are correctly assembled. A biiid or jam
2、 in the mechanism can usually be relieved tbe turntable in the reverse direction. The changer can be conveniently rotated through its by pushing the index lever to “Reject and revolving the turntable by hand. Six turntable revolutions arrequired for one change cycle. ADJUSTMENTS A. Mein Lever.This l
3、ever is basically important in that it interlinks the various individual mechanisms which control needle landing, tripping, record separation, etc. One adjust ment is provided for the main lever. Rotate the turntable until the changer is out-oLcycle; and adjust rubber bumper bracket (A) so that the
4、roller clears the nose of the cam plate by 1/16 inch. B. Friction Outch.The motion of the tone arm toward the center of the record is transmitted to the trip pawl “22“ by the trm lever “7“ through a friction clutch “5. If the motion of the pickup is abruptly accelerated or becomes irregular due to s
5、winging in the eccentric groove, the trip finger “7 moves the trip pawl “22“ into engagement with the pawl on the main gear, and the change cycle is started. Proper adjustment of the friction clutch “5“ occurs when movement of the tone arm causes positive movement of the trip pawl “22 without tenden
6、cy of the clutch to slip. The friction should be fust enough to prevent slippage, and is adjustable by means of screw “B. If adjustment is too tight, the needle will repeat grooves; if too loose, tripping will not occur at the end of the record. C. Pickup Uft Cable Screw.During the record change cyc
7、le, lever “16 is actuated by the main lever “15 so as to raise the tone arm clear of the record by means of the pickup lift cable. To adjust pickup for proper elevation, stop the changer inCycle at the point where pickup is raised to the maximum height above turntable plate, and has not moved outwar
8、d; at this point adjust locknuts “C to obtain 1 inch spacing between needle point and turntable top surface. D. at H. Needle Landing on Record. The relation of coupling between the tone arm vertical shaft and lever “20 determines the landing position of the needle on a 10 inch record. Position of ec
9、centric stud “E governs the landing of the needle on a 12 inch record; this, however, is dependent on the proper 10 inch adjustment. To adjust for needle landing, place 10 inch record on turn- table; push index lever to reject position and return to the 10 inch position; see that pickup locating lev
10、er “17 is tilted fully toward turntable; rotate mechanism through cycle until needle is just readp to land on the record; then see that pin “V on lever “14 is in contact with “Step T on lever “17.” The correct point of landing is 4-11/16 inches from the oearest side of the turntable spindle; loosen
11、the two screws “D and adjust horiiontal position of tone arm to proper dimension, being careful not to disturb levers “14 and “17. Leave approximatelv 1/32 inch end plav between hub of lever “20 and pickup base bearing, and tighten the blunt nose screw D ; run mechanism through several cycles as a c
12、heck, then tighten cone pointed screw “D. After adjusting for needle landing on a 10 inch record, place 12 inch record on turntable; push index lever to reject and return to 12 inch position; rotate mechanism through cycle until needle is just ready to land on the .ecord; the correct point of landin
13、g is 5-11/16 inches from nearest side of spindle. If the landing is incorrect, turn stud “E” until the eccentric end adjusts lever “14 to give correct needle landing. The eccentric end of the stud must always be toward the rear of the motor board, otherwise incorrect land ing may occur with 10 inch
14、records. F- fk G. Record Separating Knife. The upper plate (knife) 25 on each of the record posts serves to separate the lower record from the stack and to support the remain ing records during the change cycle. It is essential that the spacing between the knife and the rotating record shelf “27” be
15、 accurately maintained. The spacing for the 10 inch record is nominally .058 inch, and for the 12 inch record is .075 inch. ust rotete the knife to the point of minimum io adiust rotate t lao vertical separation from the record shelf and turn screw and locknut “F“ to give .055.061 inch separation. S