AB-621_mast_serv_TM11-5985-334-34_1983.pdf
《AB-621_mast_serv_TM11-5985-334-34_1983.pdf》由会员分享,可在线阅读,更多相关《AB-621_mast_serv_TM11-5985-334-34_1983.pdf(61页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-5985-334-34 TECHNICAL MANUAL DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL MAST AB-621/G (NSN 5985-00-782-5278) MAST AB-621A/G (NSN 5985-01-061-2828) EXTENSION KIT MK2044/G (NSN 5985-01-119-2925) HEADQUARTERS, DEPARTMENT OF THE ARMY FEBRUARY 1983 SAFETY STEPS TO FOLLOW IF SOMEONE IS TH
2、E VICTIM OF ELECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE , TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELECTRICAL POWER, PULL, PUSH, OR LIFT THE PERSON TO SAFETY USING A WOODEN POLE OR A ROPE OR SOME OTHER INSULATING MATERIAL SEND FOR HELP AS SOON AS POSSIBLE A
3、FTER THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DISTANCE AWAY AND IMMEDIATELY START ARTIFICIAL RESUSCITATION WARNINGS Before beginning any work on this equipment, review the general safety precautions and procedures in TB 385-4, Safety Precauti
4、ons for Main- tenance of Electrical and Electronic Equipment. Do not work on equipment alone. Be sure that a person capable of rendering first aid is present. To prevent personal injury when applying or removing steel strapping on crates or cartons, wear heavy gloves and protective eye glasses. Do n
5、ot handle cartons by the steel straps. Adequate ventilation should be provided while using TRICHLOROTRI- FLUOROETHANE. Prolonged breathing of vapor should be avoided. The solvent should not be used near heat or open flame; the products of decomposition are toxic and irritating. Since TRICHOLORTRIFLU
6、ORO- ETHANE dissolves natural oils, prolonged contact with the skin should be avoided. When necessary, use gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physician immediately. Compressed air shall not be used for cleaning purposes except where reduced to le
7、ss than 29 psi and then only with effective chip guarding and personnel protective equipment. Do not use compressed air to dry parts when TRICHLOROTRIFLUOROETHANE has been used. Compressed air is dangerous and can cause serious bodily harm if protective means or methods are not observed to prevent c
8、hip or particle (of whatever size) from being blown into the eyes or unbroken skin of the operator or other person- nel. Do not attempt to lift or move the heavy components of the AB-621(*)/G or MK-2044/G without adequate manpower. a HOW TO USE THIS MANUAL This technical manual covers maintenance pr
9、ocedures for use by direct and general support level repair personnel to maintain the AB-621(*)/G An- tenna Mast, and MK-2044/G Extension Kit. The following equipment are covered: AB-621/G Mast, 50 foot. AB-621A/G Mast, 50 or 100 foot. MK-2044/G Extension Kit, (to 100 foot) used with AB-621A/G. Inst
10、ructions apply to all AB-621(*)/G installations except when specific nomenclature notes appear. This notation method is used to identify items that are different between AB-621/G and AB-621A/G installations. The notation MK-2044/G is used to identify items used with the extension kit. Carefully foll
11、ow all the cautions and warnings in this manual. b *TM 11-5985-334-34 Technical Manual HEADQUARTERS DEPARTMENT OF THE ARMY No. 11-5985-334-34 WASHINGTON, DC, 16 February 1983 DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL Chapter 1. Section I. II. Chapter 2. Section I. II. III. IV. V. VI. Cha
12、pter 3. Section I. II. Appendix A. B. C. MAST AB-621/G (NSN 5985-00-782-5278) MAST AB-621A/G (NSN 5985-01-061-2828) EXTENSION KIT MK-2044/G (NSN 5985-01-119-2925) REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes or if you know of a way to impr
13、ove the procedures, please let us know. Mail your letter, DA Form 2028, (Recommended Changes to Publications and Blank Forms), or DA Form 2028-2 located in the back of this manual direct to: Commander, US Army CommunicationsElectronics Command and Fort Monmouth, ATTN: DRSEL-ME-MP, Fort Monmouth, NJ
14、07703. A reply will be furnished to you. Page HOW TO USE THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . b INTRODUCTION General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Equipment Description and Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 DIRECT SUPPORT MAINTENANCE INSTRUCTIONS General . . . . . . . . . . . . . .
16、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Disassembly and Reassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Maintenance Procedures MK-2044G . . .
17、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21 Cleaning, Inspection, and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26 Testing . . . . . . . . .
18、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28 GENERAL SUPPORT MAINTENANCE INSTRUCTIONS General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Maintenance Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19、.3 - 1 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 EXPENDABLE SUPPLIES AND MATERIALS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 TORQUE LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20、 . . .C-1 11-5985-334-15, 2 October 1971. *This manual together with TM 11-5985-334-10, 17 November 1982, TM 11-5985-334-20, 16 November 1982, supersedes TM i/(ii blank) TM 11-5985-334-34 CHAPTER 1 INTRODUCTION Section I. GENERAL INFORMATION 1-1. Scope Type of Manual: Direct and General Support Main
21、tenance Model Number and Equipment Name: AB-621(*)/G-Mast, Antenna (Includes AB-621/G and AB-621A/G) MK-2044/G-Kit, Extension Purpose of Equipment: Portable antenna mast used to support a variety of directional radio antennas, to an elevation of 50 or 100 feet. 1-2. Maintenance Forms, Records, and R
22、eports a. Reports of Maintenance and Unsatisfactory Equipment. Department of the Army forms and procedures used for equipment maintenance will be those prescribed by TM 38-750, The Army Maintenance Management System. b. Reportingof Packagingand Handling Deficiencies. Fill out and forward SF 364 (Rep
23、ort of Discrepancy(ROD) as prescribed in AR 735-11-2/DLAR 4140.55/NAVMATINST 4355.73/AFR 400-54/MCO 4430.3E. c. Discrepancy in Shipment Report (DISREP) (SF 361). Fill out and forward Discrepancy in Shipment Report (DISREP) (SF 361) as prescribed in AR 55-38/NAVSUPINST 4610.33B/AFR 75-18/MCO P4610.19
24、C/DLAR 4500.15. 1-3. Destruction of Army Materiel to Prevent Enemy Use Destruction of Army electronics materiel to prevent enemy use shall be in accordance with TM 750-244-2. 1-4. Preparation for Storage or Shipment a. Refer to TM 11-5985-334-10 to remove the AB-621(*)/G and MK-2044/G from service a