1、SERVICE MANUAL VHF TRANSCEIVER iF110S iF111S iF121S INTRODUCTION This service manual describes the latest service information for the IC-F110S, IC-F111S and IC-F121S VHF MOBILE TRANSCEIVER at the time of publication. DANGER NEVER connect the transceiver to an AC outlet or to a DC power supply that u
2、ses more than 16 V. This will ruin the transceiver. DO NOT expose the transceiver to rain, snow or any liquids. DO NOT reverse the polarities of the power supply when connecting the transceiver. DO NOT apply an RF signal of more than 20 dBm (100 mW) to the antenna connector. This could damage the tr
3、ansceiv- ers front end. ORDERING PARTS Be sure to include the following four points when ordering replacement parts: 1. 10-digit order numbers 2. Component part number and name 3. Equipment model name and unit name 4. Quantity required 1110003490S.ICTA31136FNIC-F110SMAIN UNIT5 pieces 8810009990 Scre
4、wPH BT M38 ZKIC-F110S Bottom cover 10 pieces Addresses are provided on the inside back cover for your convenience. REPAIR NOTES 1. Make sure a problem is internal before disassembling the transceiver. 2. DO NOT open the transceiver until the transceiver is disconnected from its power source. 3. DO N
5、OT force any of the variable components. Turn them slowly and smoothly. 4. DO NOT short any circuits or electronic parts. An insu- lated tuning tool MUST be used for all adjustments. 5. DO NOT keep power ON for a long time when the trans- ceiver is defective. 6. DO NOT transmit power into a signal g
6、enerator or a sweep generator. 7. ALWAYS connect a 40 dB to 50 dB attenuator between the transceiver and a deviation meter or spectrum ana- lyzer when using such test equipment. 8. READ the instructions of test equipment thoroughly before connecting equipment to the transceiver. To upgrade quality,
7、any electrical or mechanical parts and internal circuits are subject to change without notice or obligation. MODEL IC-F110S IC-F111S IC-F121S VERSION Europe General General U.S.A. SYMBOL EUR GEN GEN USA TABLE OF CONTENTS SECTION 1SPECIFICATIONS SECTION 2INSIDE VIEW SECTION 3DISASSEMBLY INSTRUCTIONS
8、SECTION 4CIRCUIT DESCRIPTION 4 - 1RECEIVER CIRCUITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 1 4 - 2TRANSMITTER CIRCUITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9、 . . . . . . . .4 - 2 4 - 3PLL CIRCUITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 3 4 - 4POWER SUPPLY CIRCUITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10、. . . . . . .4 - 4 4 - 5PORT ALLOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 4 SECTION 5ADJUSTMENT PROCEDURES 5 - 1PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11、. . . . . . . . . . . . . . . . . . . . . .5 - 1 5 - 2PLL ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 4 5 - 3SOFTWARE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12、 . . . . . . . . . . . . . . . . . .5 - 5 5 - 4TRIMMER ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 7 SECTION 6PARTS LIST SECTION 7MECHANICAL PARTS SECTION 8SEMI-CONDUCTOR INFORMATION SECTION 9BOARD LAYOUTS 9 - 1FRO
13、NT UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 1 9 - 2MAIN UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14、9 - 3 SECTION 10BLOCK DIAGRAM SECTION 11VOLTAGE DIAGRAMS 11 - 1 FRONT UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 1 11 - 2 MAIN UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 - 2 EXPLICIT DEFINITIONS 136 174 MHz FREQUENCY COVERAGECHANNEL SPACING Narrow/Wide-type 12.5 kHz/ 25.0 kHz 15.0 kHz/ 30.0 kHz Narrow/Middle-type15.0 kHz/ 20.0 kHz 1 - 1 SECTION 1SPECIFICATIONS All stated specifications are subject
16、to change without notice or obligation. Measurement method Frequency coverage Type of emission Number of conventional channels Antenna impedance Power supply voltage (negative ground) Current drain (approx.) Usable temperature range Dimensions (proj. not included) Weight RF output power Modulation s
17、ystem Maximum permissible deviation Frequency error Spurious emissions Adjacent channel power Audio frequency response Audio hormonic distortion FM hum and noise (typical) (without CCICT filter) Residual modulation (typical) (with CCICT filter) Limitting charact of modulator Microphone connector Rec
18、eive system Intermediate frequencies Sensitivity (typical) Squelch sencitivity (at threshold) (typical) Adjcent channel selectivity (typical) Spurious response Intermodulation (typical) Hum and noise (without CCITT filter) (typical) (with CCITT filter) Audio output power External SP connector GEN, U
19、SAEUR RECEIVERTRANSMITTERGENERAL EIA-152-C/204D or TIA-603 EN 300 086 136.000174.000 MHz N/W: (12.5 kHz; Narrow/25 kHz; Wide): 8K50F3E/16K0F3EEUR (12.5 kHz; Narrow/25 kHz; Wide): 11K0F3E/16K0F3EGEN (15 kHz; Narrow/30 kHz; Wide): 11K0F3E/16K0F3E USA N/M: (12.5 kHz; Narrow/20 kHz; Middle): 8K50F3E/14K
20、0F3E EUR Free: 8 channels, Bank: 4 channels 2 banks 50 nominal (SO-293) 13.2 V DC nominal25 W 13.6 V DC nominal50 W TX: 7.0 A(at 25 W), 14.0 A(at 50 W) RX: 1200 mA(max. audio) 300 mA(stand-by) 30C to +60C (22F to +140F)25C to +55C (13F to +131F) 150(W)40(H) 117.5(D) mm; 52932(W)1916(H) 458(D) inch25
21、 W 150(W)40(H) 167.5(D) mm; 52932(W)1916(H) 41932(D) inch50 W 0.8 kg; 1 lb 12 oz 25 W, 1.1 kg; 2 lb 7 oz 50 W High/Low2/Low1: 25 W/10 W/2.5 W25 W 50 W/25 W/5 W50 W Variable reactance frequency modulation 2.5 kHz Narrow, 4.0 kHz Middle, 5.0 kHz Wide 5.0 ppm1.5 kHz 70 dBc typical0.25 W 1GHz, 1.0 W 1 G
22、Hz 60 dB Narrow, 70 dB Middle, Wide +2 dB to 8 dB of 6 dB/octave range from 300 Hz to 2550 Hz Narrow/3000 Hz Middle, Wide 3% typical at 1 kHz, 40% deviation 40 dB Narrow, 46 dB Wide 50 dB Narrow, 53 dB Middle 55 dB Wide 70100% of max. deviation 8-pin modular (600 ) Double-conversion superheterodyne
23、system 1st: 46.35 MHz, 2nd: 450 kHz 0.25 V at 12 dB SINAD4 dBV (emf) at 20 dB SINAD 0.25 V4 dBV (emf) 65 dB Narrow, 75 dB Middle/Wide 75 dB 74 dB67 dB 40 dB Narrow, 45 dB Wide 50 dB Narrow, 53 dB Middle, 55 dB Wide 4 W typical at 10% distortion with a 4 load 2-conductor 3.5 (d) mm (18)/4 2 - 1 SECTI
24、ON 2INSIDE VIEW Antenna switch/ Low-pass filter circuit Mixer* (Q3: 3SK299) 2nd IF filter* (FI2: ALFYM450F=K) D/A converter* (IC6: M62363FP-650C) IF IC (IC1: TA31136FN) 1st IF filter (FI1: FL-335) * Located under side of the point. Final FET module IC3:RA30H131725W S-AV3250W CPU 5V regulator* (IC10:
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Icom_IC F110S_IC F111S_IC F121S_IC F210S_IC F211S_IC F221S_serv
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-197808.html



Marshall-9100-62-02-Schematic电路原理图.pdf