Anritsu 11410-00225 电路图.pdf
《Anritsu 11410-00225 电路图.pdf》由会员分享,可在线阅读,更多相关《Anritsu 11410-00225 电路图.pdf(14页珍藏版)》请在收音机爱好者资料库上搜索。
1、The Worlds Leading Cable and Antenna System Analyzer Site Master Transmission Line and Antenna Analyzer 2 MHz - 20 GHz RadioFans.CN 收音机爱 好者资料库 THE LEADING CABLE AND ANTENNA ANALYZER FOR WIRELESS PROFESSIONALS Anritsus Site Master cable and antenna analyzer is the preferred choice of service provider
2、s, network operators and contractors worldwide who install, deploy, maintain and troubleshoot wireless communi- cation systems. Featuring an advanced synthesizer-based, handheld, battery-operated design, Site Master helps wireless field engineers and technicians detect cable feedline and antenna sys
3、tem problems before they become costly, time-consuming system failures. Superior immunity to ambient RF levels, and excellent directivity and source match ensure accurate and repeatable measurements. Easy-to-Use Site Masters menu driven interface requires little training and simplifies the field eng
4、ineers and technicians task of deployment, site-to-site maintenance and troubleshooting by identifying, recording and solving problems without sacrificing measurement accuracy. Store ten test setups for fast repeatable testing. Store up to 200 measurement traces in nonvolatile memory. Quickly select
5、 cable type and test parameters without setup error. Multilingual user interface features on screen menus and messages in 6-different languages. InstaCalcalibration module simplifies Site Master calibration. Accurate, Repeatable Measurements Utilizing vector error correction, Site Master delivers ac
6、curate, reliable and repeatable Return Loss/SWR and Fault Location measurements. Site Masters high immunity to interference allows users to conduct measurements of an active site without the loss of accuracy. Locate long range problems with 517 data points. Superior immunity to on-channel interferen
7、ce for testing at co-located antenna sites. Large, high-resolution display allows for easy viewing and trace interpretation under a variety of conditions. Full range of marker and limit functions facilitate quick, comprehensive measurements. Rugged and Reliable Designed specifically for field enviro
8、nments, Site Master withstands harsh environments and rough handling. Built-in energy conservation combined with a rechargeable battery pack allows users to extend battery life beyond an eight hour work day. Site Master can also be operated from a 12.5 Vdc source such as an AC-DC adapter or automoti
9、ve cigarette lighter adapter, which also simultaneously charges the battery. Powerful Data Analysis Software Powerful data analysis software comes with every Site Master unit, providing users with an easy method of analyzing system performance, trends and problems in addition to professional report
10、generation. Site Master PC software is Windows 95/98/NT4/2000/ME/XP workstation compatible and supports long alpha-numeric file names for descriptive data labeling. Store an unlimited number of data traces for comparison to historical performance. Quickly and easily download data traces from the Sit
11、e Master to a PC database with a single menu selection. Site Master Software Tools provides a data base to compare maintenance interval performance to site commissioning data. The Distance-To-Fault display pinpoints problem areas before they degenerate into failures. In the graph to the left, a loos
12、ened connector changes the return loss characteris- tic from 38 dB to 33 dB (90 dB isolation ranges required at RF-RF repeater sites. Measuring antenna isolation during periodic maintenance intervals conveniently verifies antenna position after harsh weather. If the antenna has been moved from the i
13、nstalled mounting angle, the change in side lobe and back lobe coupling magnitudes between the antennas causes a clear performance change.Tx-Rx isolation of duplexers and filters is easily tested with Site Masters 90 dB dynamic range. Filters are easily aligned and verified to manufacturers specific
14、ations. Site Masters high dynamic range enables LNA measurements at ground level. Accurately measure antenna isolation with Site Masters high dynamic range. Amplifier Gain Test Measurement. 2-PORT SITE MASTER RF IN RF OUT ANTENNA ANTENNA ISOLATION 2-PORT SITE MASTER RF IN RF OUT LNA 2-PORT SITE MAST
15、ER RF IN RF OUT LNA ANTENNA TEST SIGNALANTENNA LNA DUPLEXER Tx Rx 5 SITE MASTER S800 SERIES FOR MICROWAVE APPLICATIONS The Site Master S800 series, is the most accurate and convenient tool available for field installation, verification, troubleshooting and repair of microwave communication systems.
16、Difficult test specifications are easy to verify.The S800 series improves quality and reduces maintenance expenses by providing vector corrected calibration and a convenient user interface.These new microwave Site Master models test both waveguide and coaxial cables more conveniently than laboratory
17、-sized scalar analyzers or microwave test sets. Vector Error Correction Vector error correction within the S800 series improves the quality and convenience of measurements compared to traditional scalar techniques. Accuracy and repeatability account for errors such as test port match and source matc
18、h errors.Vector correction allows the test port to achieve the highest commercial directivity to 50 dB (frequency range dependent) using relatively small calibration components. Waveguide Dispersion Vector error correction also improves the quality of Distance- To-Fault data. Not only is the reflect
19、ion magnitude more accurate, but the waveguide dispersion correction for fault location (different frequencies propagate at different speeds) is more accurate and repeatable.The post- vector corrected data accounts for the non- dispersive length of coaxial cable preced- ing the input of the waveguid
20、e under test. Unlike scalar-based systems, the Site Master S800 Series do not suffer reflec- tion magnitude errors (a failure looks better than actual) and length inaccuracies in proportion to the relative lengths of the coaxial input cable and waveguide under test. SITE MASTER ANTENNA REFERENCE PLA
21、NE TEST PORT CABLE COAX-TO-WAVEGUIDE ADAPTER FLEX WAVEGUIDE JUMPER FLEX WAVEGUIDE JUMPER CALIBRATION COMPONENTS PRESSURIZED WAVEGUIDE TRANSMISSION LINE 1/8 WAVEGUIDE SHORT 3/8 WAVEGUIDE SHORT WAVEGUIDE LOAD Vector Correction Avoids Bulky Waveguide Coupler Waveguide Calibration The test port interfac
22、e to the waveguide under test is a small coaxial-to-waveguide adapter rather than a bulky precision coupler. The calibration components include two offset shorts,1/8 and 3/8 wavelength, and a precision load.The two offset shorts eliminate reference error suffered by scalar systems when only a single
23、 waveguide short is used to determine the 0.0 dB reflection reference level. Site Masters innovative flange design mates to square, rectangular or circular flanges. For a given waveguide size, only one calibration set is required. Site Masters waveguide calibration components are built with precisio
24、n alignment pins that mate the companion coaxial to waveguide adapters. As a result, proper alignment of waveguide is fast and convenient. 6 SITE MASTER WITH INTEGRATED SPECTRUM ANALYSIS CAPABILITY Site Master models S114C and S332C add spectrum analysis capability to the standard cable and antenna
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Anritsu 11410-00225 电路图 11410 00225
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf