Biddle CFL535F_UG 电路图.pdf
《Biddle CFL535F_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle CFL535F_UG 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、Cable Fault Locator MEGGER CFL535F User Guide MEGGER CFL 535F english 4/1/02 9:21 am Page 1 RadioFans.CN 收音机爱 好者资料库 SAFETY WARNINGS This instrument meets the safety requirements of IEC 61010 part 1 to 300V CAT III. Although this tester does not generate any hazardous voltages, circuits to which it c
2、an be connected could be dangerous due to electric shock hazard or due to arcing (initiated by short circuit). While every effort has been made by the manufacturer to reduce the hazard, the user must assume responsibility for ensuring his or her own safety. For use on energised systems rated up to 3
3、00V Installation Category III* use the fused clip set AVO Part Number 6111-218, must be used. * Relates to the transient over voltages likely to be met in fixed wiring installations. CAUTION (Risk of electric shock) 4mm plug to BNC Adaptor: This 4mm plug to BNC adapter is intended for use with telec
4、omm network cables only, it is not designed or intended for direct connection to an energised mains supply. However, in normal use it may be subject to telecom network voltages (TNV) as defined by IEC 60950 3rdedition (1999-04). The BNC plug and socket are, by necessity, accessible. The outer sheath
5、 for this connector is normally at SELV levels, however under single fault conditions it may carry hazardous voltages. The operator must therefore verify that the accessible plug or socket is at SELV levels prior to touching, or alternatively wear appropriate insulated gloves. The instrument should
6、not be used if any part of it is damaged. Test leads and crocodile clips must be in good order, clean and with no broken or cracked insulation. Check that all lead connections are correct before making a test. A Fused Lead Set must be used to connect to energised live systems. Refer to the accessori
7、es section for options. Disconnect the test leads before accessing the battery compartment. Refer to operating instructions for further explanation and precautions. Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. 2 NOTE THE
8、 INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. CFL 535F english 4/1/02 9:21 am Page 2 RadioFans.CN 收音机爱 好者资料库 Saving a trace to memory Recalling a trace from memory Downloading a trace to a PC Uploading stored trace from PC to TDR Techniques for Improving Accuracy14 Test th
9、e cable from both ends Care and Maintenance15 Specification15 Accessories17 Repair and warranty18 Symbols used on the instrument are: Caution: Refer to accompanying notes. Equipment protected throughout by double or reinforced insulation. Instrument flash tested to 3.7kV rms. Equipment complies with
10、 current EU directives. Contents 3 Safety Warnings2 Introduction4 User Display the second, a short circuit at 1.200km away. CFL 535F english 4/1/02 9:21 am Page 11 If the velocity factor of the cable under test (C.U.T) is not known, it may be accurately established by: Testing a known length of cabl
11、e, locate the reflection for the end of the cable on the display. Use the shortest possible range setting. Use the ZOOM button to accurately position the distance cursor. Adjust the velocity factor of the TDR using the VF key (4) until the TDR displays the correct length of cable. Make a note the VF
12、 value for future reference. The table of velocity factors in the HELP pages of the instrument is a rough guide and in practice, the settings are subject to many variable factors. By using the previous procedure on a known length of cable, a more accurate VF can be established. The measurement of th