Yaesu_VL-1000_user.pdf
《Yaesu_VL-1000_user.pdf》由会员分享,可在线阅读,更多相关《Yaesu_VL-1000_user.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、VL-1000 O O O O OPERATINGPERATINGPERATINGPERATINGPERATING M M M M MANUAL ANUALANUALANUALANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD U.S.A. Inc. 6125 Phyllis Drive, Cypress, California 90630, U.S.A. YAESU UK LTD. Unit 12, Sun Valley Business Park
2、, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD. Unit 1306-1308, 13F., Millennium City 2, 378 Kwun Tong Road, Kwun Tong, Kowloon, Hong Kong VERTEX STANDARD (AUSTRALIA) PTY., LTD. Tally Ho Business Park, 10 Wesley Court, East Burwood, VIC, 3151 Page 1VL-1000 Operating Man
3、ual General Description Congratulations! You are now the owner of the Yaesu VL-1000 Linear Amplifier, which brings you leading-edge technology for the ultimate in operating convenience and reliability. We appreci- ate your investment in Yaesu equipment, and wish you many years of satisfying operatio
4、n using your new amplifier! The VL-1000 is an all-solid-state linear amplifier operating on the 160 through 6 meter amateur bands (USA version: 160-15 meters) at a power output level of 1000 Watts on CW and SSB (500 Watts on continuous data modes such as RTTY). The VL-1000 includes a built-in antenn
5、a tuner with 240 memories for tuning data, and microprocessor control of the tuning circuitry. The VL-1000 features input jacks for two different exciters, as well as four antenna jacks for connection of antennas for different bands. Extensive self-test, system monitoring, and protection circuits ar
6、e provided, with status and tuning information being displayed on a huge Liquid Crystal Display panel. The separate VP-1000 Power Supply Unit provides the +48 Volts required by the PA transis- tors, as well as all required control voltages for the amplifier. The VL-1000 normally is powered via 220 V
7、olt AC mains, although it can be operated, at the 500 Watt level, from 117 Volt AC power. We encourage you to read this manual thoroughly before beginning installation and operation of your VL-1000 Linear Amplifier. The details regarding proper installation and operating advice contained in these pa
8、ges will help you derive maximum satisfaction from your new Yaesu equip- ment. Be certain to observe all due safety precautions when using this high-power device! Supplied Accessories Item Quantity ALC Cable (T9101489; 2 m) 1 Band Data Cable (T9101487A; 8-pin DIN 8-pin DIN, 2 m) 1 Control Cable (T91
9、01491; D-sub 15-pin RCA, 2 m) 1 Page 2VL-1000 Operating Manual Installation The proper, safe installation of the VL-1000 is not difficult to accomplish, using the guide- lines to follow. Caution! Lethal AC and RF voltages are present within the cabinets of the VL-1000 Lin- ear Amplifier and VP-1000
10、Power Sup- ply. Use extreme caution when open- ing the cabinet(s) to perform any alignment or adjustment steps, and take particular care to inspect inter- connection cables frequently to en- sure that they are in good condition. It is assumed that you possess tech- nical knowledge and experience con
11、- sistent with your possession of an amateur radio license; this knowledge and experience are important tools which will aid in the successful instal- lation of this apparatus. Should you have any questions about the safe in- stallation of this equipment, consult your Yaesu dealer or seek the assis-
12、 tance of a professional installer. AC Power Connections (using VP-1000 Power Supply) The VL-1000 is usually operated from 220 Volt (nominal) AC power. With 220 Volt input to the VP-1000 Power Supply, full (1000 W) power output will be obtained from the VL- 1000, while 117 Volt input to the VP-1000
13、is possible at the 500 Watt power output level. The advanced switching-regulator power supply used in the matching VP-1000 Power Supply does not require any transformer re- wiring, nor any changing of a switch position; the power supply will operate from either 220 or 117 Volt line voltages without
14、configuration changes. However, the AC power cable/plug configu- ration will be somewhat different, depending on the country in which you purchased your amplifier. In some countries, the VP-1000 is shipped with the standard 220 Volt connector appropriate for your location. In those areas where there
15、 are multiple 220 Volt connectors in common use, the VP-1000 is shipped with- out the power connector; one may be obtained at a local hardware or electrical supply store. Pictorial diagrams of the common 220 and 117 Volt AC connectors in use are shown be- low. When wiring your own connector, be ab-
16、solutely certain to observe the proper polarity on the pin connections. Consult with an elec- trician if you have any doubts about your wir- ing! Be sure that your house wiring is capable of sufficient current capacity on the 220 Volt circuit to be used, especially if this circuit is shared with hou
17、sehold appliances. It always is preferable to operate the VL-1000 from a dedicated 220 Volt circuit with its own circuit breaker. Transceiver or Exciter Interconnections The interface wiring to the transceiver or trans- mitter which drives the VL-1000 consists of: (A) A 50 coaxial cable for carrying
18、 RF drive power from each exciter to the amplifier; (B) A 2-conductor transmit/receive control cable which provides a closure to ground signal from the transceiver to the amplifier during transmission; (C) A (supplied) 2-conductor ALC (Automatic Level Control) line, used to limit the drive level fro
19、m the exciter to the amplifier; and (D) When using a compatible Yaesu trans- UK PlugAustralian Plug European Plug USA Plug (viewed from plug prong side) VP-1000 AC Cable wiring (European version) (U.S.A version) Page 3VL-1000 Operating Manual Installation FT-920/VL-1000 FT-1000MP/FT-650/VL-1000 nect
20、ed to the INPUT 1/PTT 1/ALC 1 jacks, and that all cables from exciter #2 are connected to the INPUT 2/PTT 2/ALC 2 jacks. When us- ing a BAND DATA cable for interconnection, you do not need the PTT cable for the correspond- ing exciter, as the T/R control signal will be made via the BAND DATA cable.
21、ceiver, a BAND DATA cable may be con- nected which provides automatic band change and T/R control (thus eliminating the need for cable (B) above), and +48 V DC supply voltage On/Off control (if the REMOTE switch on the rear panel of the VL-1000 is set to the ON position). Typical installation diagra
22、ms are shown below. When two exciters are utilized, be cer- tain that all the cables from exciter #1 are con- Page 4VL-1000 Operating Manual connections labeled TX GND on the rear panel of the transceiver; do not, however, use the transceivers PTT jack, as it was designed for PTT input (via a footsw
23、itch, etc.), not for am- plifier control. Automatic Amplifier Tune-Up If you connect the supplied control cable be- tween the transceivers PTT or REMOTE jack and the VL-1000s BAND-DATA 2 jack, the trans- ceiver will automatically transmit when you press the amplifiers front panel F SET key (make sur
24、e that the MODE switch of the trans- ceiver is set to CW, RTTY, or some other con- tinuous mode, and set the DRIVE or RF PWR control fully clockwise, if you want to perform antenna tuning). To accomplish this function, pin 11 of the BAND-DATA 2 jack closes the transceivers PTT or REMOTE jack to grou
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yaesu_VL 1000 _user
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


