1、KI-1734A 2524 Master Clock Clock-function Installation and Drawings RAULAND-BORG CORPORATION l 3450 West Oakton Street, Skokie, Illinois 60076-2951 l (847) 679-0900 Table of Contents General Information 2 Description . Unpacking. . Manuals. . Communications Functions . . . . . . . 2 . 2 . 2 . 2 Spec
2、ifications Planning 2 2 i. . ._. Zones . Associated Equipment. . Clock Equipment . Output Terminals . Installation ., 2 ., ., ., 3 4 . 3 . 3 . . Jumpers . Rack Mounting. . Wiring . Screw-Terminal Cover. . Signaling Devices and Equipment. . Correctable Secondary Clocks . With Separate Telecenter Syst
3、ems. Turning on the 2524. . Functional Descriptions 6 Music Events . 6 With Separate Telecenter* Systems. . 6 As Controller of Telecenter 1100 Communications Systems . 6 Secondary Clock-Codes: Table and Wiring Diagrams 7 Secondary-Clock Wiring Figures l-26 Special Application Wiring Figures 27-29 Ot
4、her Drawings Connecting Signaling Devices and Equipment . KM0987 Connecting a Serial Device to a 2524. KM0991 Clock and Intercom Controller Jumpers IL0341 0 1992 RAULANDBORG CORPORATION l Pmted m U.S.A Page 1 of 40 Orig. 12/92. Rev 7/96. 173401 RadioFans.CN 收音机爱 好者资料库 2524 Master Clock Installation
5、General Information Description The Rauland 2524 combines the full features of a master clock with intercom-control ability. As a master clock, it can correct virtually any secondary clocks and control up to 350 “events” (such as ringing bells or turning lights and equipment on and off). 2524 Clock
6、and Communications Installation . . , . . . . . KI-1628 2524 Clock and Communicahons Programming . . . , KI-1629 2524 Clock and Communications Operalion . . . . . . KI-1630 These manuals cover both communications and clock functions. The units L.EDS and keypad make it easy to enter and check all pro
7、gramming. Of special note is the ease with which any part of the programming can be accessed and changed without having to cycle through many other parts and without having to re-enter everything else. Unpacking Manuals This manual tells how to install the 2524 for clock functions only. Instructions
8、 on programming and operating the 2524 for clock functions only are in KI-1733. The 2524 is shipped with all the hardware needed to mount it in a rack. Locate the following items before discarding the packing material: Rauland Qv- DescriptionPart No. 4#132 x ?g black machine screw.B0439 4#lO Flat Wa
9、sher.WJo305 4Fiber Washer.WLo315 4Tinnerman for #lO-32 mounting screw.AB3640 Communications Functions For information on communications functions, refer to the following manuals: Specifications Programming Capacity: Up to 350 Events and 100 Holidays. LED Digit Displays: Mode, Time, and Schedule. LED
10、 Indicators: AM and PM 8 Zones/Outputs 7 Days, Music, Clock, and Communication (COMM). Keyboard: 18 Buttons: “0 through 9,” Left and Right Cursors, four functions, Clock-Comm select, and Manual. outputs: 8 Zone/Output contacts, each with a relay (120VAC, 5- Amp resistive). Power Failure Back-up: Fiv
11、e-year, 3-volt lithium battery. Power Required: 120-230 volts, 50 or 60 Hz, 20 watts. Dimensions: 19” (48.3 cm) panel, 3” (8.9 cm) high, 9” (24.1 cm) deep (including rear conduit box). Net Weight: 9 Ibs. (4.1 kg). Planning The attached wiring diagrams show typical installations for the 2524 used as
12、a master clock. There is also helpful information further on, in “Associated Equipment.” Zones What may require closer attention in more complex installa- +;fi.r ;. +t.a .,;., +rr ? t.- 7C7Ar7n+,/n.,fn.,r t.arm;nlr Cnr a Ll”IJ ,a L MOTOR 2524 I Correction Code (Mode A) #09 I I I I I I I I I I I I I
13、I I -aw I SECONDARY CLOCK Correction Timing every hour From X:00:00 From 5.12:00 To X:59:25. Y is activated for 35 seconds every hour From X:59:25 To X:00:00. * See “Correctable Secondary Clocks” (under “Wiring”) to determine the output terminals. Figure 9. . ., . . .- Correction Code (Mode A) #10 M
14、inute Impulse I Y is activated for 2 seconds every minute From X:XX:58 To X:XX:00. “X is pulsing at the rate of 1 second on and 1 second off. Not Applicable * See “Correctable Secondary Clocks” (under “Wiring”) to determine the Figure 10. KM0962 FAST ADVANCE MOTOR 1 RUN MOTOR ; 1 RPM I 59TH MINUTE I
15、 I I I I I I I I I I I I I SECONDARY CLOCK is activated for 59 minutes, 6 seconds To (X+1):58:05. Y is activated for 54 seconds every hour Not Applicable * See “Correctable Secondary Clocks” (under “Wiring”) to determine the output terminals. Figure 11. KM0963 0 120/24VAC 2524 Correction Code (ModeA
16、) #12 I I 120/24VAC I CORR COIL I I I . ., : :,.: I I I I I 1 I I I I I I Hourly is activated for 8 seconds every hour From X:57:54 To X:58:02. l2-Hour “X” is activated for 14 seconds every 12 hours From 5:57:54 To 5:58:08. * See “Correctable Secondary Clocks” (under “Wiring”) to determine the outpu