Jvc-NXMD-1-Service-Manual(1) 电路图 维修手册.pdf
《Jvc-NXMD-1-Service-Manual(1) 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Jvc-NXMD-1-Service-Manual(1) 电路图 维修手册.pdf(69页珍藏版)》请在收音机爱好者资料库上搜索。
1、COMPACT COMPONENT MD SYSTEM NX-MD1R / NX-MD1 NX-MD1R/NX-MD1 No.21041 Oct. 2001 COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD. Contents Safety precautions Preventing static electricity Important for laser products Disassembly method Adjustment method (CD/MD section) Flow of functional operation until T
2、OC read (CD) Flow of functional operation until TOC read (MD) Maintenance of laser pickup (CD) Replacement of laser pickup (CD) Maintenance of laser pickup(MD) Replacement of laser pickup(MD) Description of major ICs 1-2 1-3 1-5 1-6 1-32 1-37 1-38 1-39 1-39 1-40 1-40 1-4168 SERVICE MANUAL CA-NXMD1R/
3、CA-NXMD1SP-NXMD1SP-NXMD1 Area suffix NX-MD1 A - Australia US - Singapore UB - Hong Kong UP - Korea Area suffix NX-MD1R B - U.K. E - Continental Europe EN - Northern Europe RadioFans.CN 收音机爱 好者资料库 NX-MD1R/NX-MD1 1-2 1. This design of this product contains special hardware and many circuits and compon
4、ents specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. 2. Al
5、terations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage
6、 resulting therefrom. 3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for high
7、er voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a subs
8、titute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be
9、separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assem
10、bling. 5. Leakage currnet check (Electrical shock hazard testing) After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe t
11、o operate without danger of electrical shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part ha
12、ving a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,5
13、00 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to
14、 the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet internationa
15、l safety standards. 2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained. 3. Repairs must be made in accordance with the relevant safety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. If mains voltage
16、 selector is provided, check setting for local voltage. Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attent
17、ion to such burrs in the case of preforming repair of this system. In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby ar
18、e critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the J and C version) RadioFans.CN 收音机爱 好者资料库 NX-MD1R/NX-MD1 1-3 Preventing static electricity 1. Grounding to prevent damage by static electricity Electrostatic
19、discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 2. About the earth processing for the destruction prevention by static electrici
20、ty Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. 2-1 Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet
21、) or an iron plate over it before placing the traverse unit (optical pickup) on it. 2-2 Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup 1. In order to maintain quality during transport and before installation, bot
22、h sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) 2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily
23、 destroy the laser diode. 4. Handling the traverse unit (optical pickup) 1. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. 2. Remove solder of the shorting round on the flexible wire after replacing the optical pickup. For specific details, re
24、fer to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long a time when attaching it to the connector. 3. Handle the flexible wire carefully as it may break when subjected to strong force. 4. It is not possible to adjust