JVC-XVC5SL-cd-sm 电路图 维修手册.pdf
《JVC-XVC5SL-cd-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《JVC-XVC5SL-cd-sm 电路图 维修手册.pdf(74页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD. No.XA001 2003/5 DVD VIDEO PLAYER XA00120034 XV-C5SL TABLE OF CONTENTS 1Important Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2Disassembly met
2、hod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . 16 4Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 TV2 2 TV1 1 TV3 3 TV5 5 TV4 4 TV6 6 TV8 8 TV7 7 TV9 9 TV0 0 TV-/- 10 MUTING +10 VFPZOOM AUDIO DIMMER SUB TITLE REPEAT ANGLE 3D PHONIC
4、AMP VOL EJECT DISPLAY TVDVD NEXTPREVIOUS SELECTCLEAR SLOW SLOW + CH + CH ENTER STANDBY/ON TVDVD RETURN VOLVOL+ TITLE/ GROUP TV/VIDEO CANCEL T O P M E N U M E N U O N S C R E E N C H O I C E Area Suffix B - U.K. E - Continental Europe EN - Northern Europe EV - Eastern Europe EE - Russian Federation U
5、S - Singapore UG - Turkey,South Africa,Egypt UB - Hong Kong RadioFans.CN 收音机爱 好者资料库 1-2 (No.XA001) SPECIFICATION Specifications and appearance are subject to change without prior notice. Manufactured under license from Dolby Laboratories. Dolby and the double-D symbol are trademarks of Dolby Laborat
6、ories. Con- fidential unpublished works. Manufactured under license from Digital Theater Systems, Inc. DTS, DTS Digital Surround, are trademarks of Digital Theater Systems, Inc. Digital output signal chart GeneralReadable discsDVD VIDEO, DVD-R (Video format),DVD-RW (Video format), +RW(Video format),
7、 SVCD, Video CD,Audio CD (CD-DA), MP3 format,JPEG, CD-R/ RW (CD-DA, SVCD,Video CD, MP3 format, JPEG) Video formatPAL OtherPower requirementsAC 230 V , 50 Hz Power consumption12 W (POWER ON), 0.7 W (STANDBY mode) Mass1.7 kg Dimensions (W x H x D)218 mm x 58 mm x 270 mm Video outputsVIDEO OUT (pin jac
8、k)1.0 Vp-p (75 ) Horizontal resolution500 lines or more RGB700 mVp-p (75 ) Audio outputsANALOG OUT (pin jack)2.0 Vrms (10 k) DIGITAL OUT (COAXIAL)0.5 Vp-p (75 termination) DIGITAL OUT (OPTICAL)-21 dBm to -15 dBm (peak) Audio characteristicsFrequency responseCD(sampling frequency 44.1 kHz):2 Hz to 20
9、 kHz DVD(sampling frequency 48 kHz):2 Hz to 22 kHz (4 Hz to 20 kHz for DTS and Dolby Digital bitstream signals) DVD(sampling frequency 96 kHz):2 Hz to 44 kHz Dynamic range16 bit: More than 98 dB 20 bit: More than 100 dB 24 bit: More than 100 dB Wow and flutterUnmeasurable (less than + 0.002%) Total
10、harmonic distortionless than 0.006% Disc type Output PCM ONLYDOLBY DIGITAL/PCMSTREAM/PCM DVD with 48 kHz 16/20/24 bit linear PCM48 kHz 16 bit stereo linear PCM DVD with 96 kHz 16/20/24 bit linear PCM48kHz 16 bit stereo linear PCM (Down sampling) DVD with DTSNo outputDTS bitstream DVD with Dolby Digi
11、tal48 kHz 16 bit stereo linear PCMDolby Digital bitstream DVD with MPEG Multichannel48 kHz 16 bit stereo linear PCMMPEG bitstream SVCD/Video CD/Audio CD44.1 kHz 16 bit stereo linear PCM Audio CD with DTSNo outputDTS bitstream CD-R/RW with MP3Linear PCM RadioFans.CN 收音机爱 好者资料库 (No.XA001)1-3 SECTION 1
12、 Important Safety Precautions 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer.
13、 Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or a
14、dditions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often
15、 not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Elec
16、trical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Man
17、ual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When ser
18、vice is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing) After reassembling the product, always perform an isola- tion check on the exposed metal parts of the p
19、roduct (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Lea
20、kage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cor
21、d directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensi- tivity in the following manner. Connect a 1,500 ohm 10W resistor paralleled by a 0.15 F AC-type capacitor be- tween an exposed metal part and a known good earth ground. Measure the AC voltage across the res
22、istor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must
23、 not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must b
24、e made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassi
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-XVC5SL-cd-sm 电路图 维修手册 JVC XVC5SL cd sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


