1、 Panasonic Corporation 2012. All rights reserved. Unauthorized copying and distribution is a violation of law. PSG1203032AE A6 CD Stereo System Model No.SA-AKX14P Product Color: (K).Black Type TABLE OF CONTENTS PAGEPAGE 1 Safety Precautions- 3 1.1. General Guidelines- 3 1.2. Before Repair and Adjust
2、ment- 3 1.3. Protection Circuitry- 3 1.4. Caution For Fuse Replacement- 4 1.5. Safety Parts Information - 4 2 Warning- 5 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive (ES) Devices-5 2.2. Precaution of Laser Diode-6 2.3. Service caution based on Legal restrictions -7 2.4
3、. Handling Precautions for Traverse Unit -8 3 Service Navigation - 10 3.1. Service Information- 10 3.2. Differences Table - 11 Please refer to the original service manual for: 1) SA-AKX14P is base on SA-AKX14PN-K, Order No. PSG1201003CE. 2) CD Mechanism Unit (BRS1C), Order No. PSG1102001CE. 3) Speak
4、er system SB-AKX14P-K, Order No. PSG1203033AE. RadioFans.CN 收音机爱 好者资料库 2 4 Specifications-12 5 Block Diagram -13 5.1. Power Supply -13 6 Schematic Diagram-15 6.1. Main Circuit-15 6.2. SMPS Circuit-19 7 Printed Circuit Board -21 7.1. Main P.C.B. & Tuner P.C.B. -21 7.2. Panel, LCD, Remote Sensor & USB
5、 P.C.B.-22 7.3. SMPS P.C.B. -23 8 Exploded View and Replacement Parts List -24 8.1. Exploded View and Mechanical Replacement Parts List -24 8.2. Electrical Replacement Parts List-29 RadioFans.CN 收音机爱 好者资料库 3 1Safety Precautions 1.1.General Guidelines 1. When servicing, observe the original lead dres
6、s. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed. 3. After servicing, carry out the following leaka
7、ge current checks to prevent the customer from being exposed to shock hazards. 1.1.1.Leakage Current Cold Check 1. Unplug the AC cord and connect a jumper between the two prongs on the plug. 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cab
8、inet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1M and 5.2M. When the exposed metal does not have a return path to the chassis, the reading must be (This “Safety Precaution”
9、 is applied only in U.S.A.) 1. Before servicing, unplug the power cord to prevent an electric shock. 2. When replacing parts, use only manufacturers recommended components for safety. 3. Check the condition of the power cord. Replace if wear or damage is evident. 4. After servicing, be sure to resto
10、re the lead dress, insulation barriers, insulation papers, shields, etc. 5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the customer from being exposed to a shock hazard. 1.1.2.Leakage Current Hot Check 1. Plug the AC c
11、ord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1. 3. Use an AC voltmeter, wi
12、th 1000 ohms/volt or more sensitivity, to measure the potential across the resistor. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at any point should not exceed 0.75 vol
13、ts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked
14、before it is returned to the customer. Figure 1 1.2.Before Repair and Adjustment Disconnect AC power to discharge unit AC Capacitors as such (C5700, C5701, C5703, C5704, C5705, C5708) through a 10 , 10 W resistor to ground. Caution: DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instan
15、ce), as this may destroy solid state devices. After repairs are completed, restore power gradually using a variac, to avoid overcurrent. Current consumption at AC 120V, 60 Hz in Power ON, FM Tuner, No Signal, Volume minimal mode should be 500 mA 1.3.Protection Circuitry The protection circuitry may
16、have operated if either of the following conditions are noticed: No sound is heard when the power is turned on. Sound stops during a performance. RadioFans.CN 收音机爱 好者资料库 4 The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wire
17、s are “shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used. If this occurs, follow the procedure outlines below: 1. Turn off the power. 2. Determine the cause of the problem and correct it. 3. Turn on the power once again after one minu
18、te. Note: When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again. 1.4.Caution For Fuse Replacement 1.5.Safety Parts Information Safety Parts List: There are special components used in this equipment which are important for safety. Th
19、ese parts are marked by () in the Exploded View & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturers specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer. SafetyRef No.Part N
20、o.Part Name & DescriptionRemarks 20RKMX1011-K1TOP CABINET 21RGRX1008K-FREAR PANEL 301RAEX1033Z-VTRAVERSE ASSY A2K2CB2YY00059AC CORD A3RQT9691-1PO/I BOOK (En) PCB8REP4783AASMPS P.C.B.(RTL) DZ5701ERZVA5Z471ZNR L5701G0B932H00002LINE FILTER T5701G4DYZ0000057MAIN TRANSFORMER T5751ETS19AB2E6AGSUB TRANSFOR
21、MER PC5701B3PBA0000503PHOTO COUPLER PC5702B3PBA0000503PHOTO COUPLER PC5720B3PBA0000503PHOTO COUPLER PC5799B3PBA0000503PHOTO COUPLER F1K5D802APA008FUSE TH5702D4CAA2R20001THERMISTOR TH5860D4CC11040013THERMISTOR TH5900D4CC11040013THERMISTOR P5701K2AB2B000007AC INLET R5708ERJ8GEYJ155V1.5M 1/4W R5709ERJ8
22、GEYJ155V1.5M 1/4W C5700F1BAF471A013470pF C5701F0CAF104A1050.1uF C5703F0CAF224A1050.22uF C5704F1BAF471A013470pF C5705F1BAF471A013470pF C5708F1BAF10200201000pF 5 2Warning 2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive (ES) Devices Some semiconductor (solid state) devices ca
23、n be damaged easily by static electricity. Such components commonly are called Elec- trostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and semiconductor “chip” components. The following techniques should be used to help red
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Panasonic-SAAKX14P-cs-sm 电路图 维修手册 Panasonic SAAKX14P cs sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf