Zenith-DVD5201-cd-sm电路图 维修手册.pdf
《Zenith-DVD5201-cd-sm电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Zenith-DVD5201-cd-sm电路图 维修手册.pdf(51页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL Product Type:DVD Player Chassis:DVD2 Manual Series: VR166 Manual Part #: 923-03461 Model Line:D Product Year:2001 OVERVIEW .5 DISASSEMBLY .8 MECHANISM .10 ELECTRICAL. 14 PARTS.28 DIAGRAMS .37 SCHEMATICS .38 Published by Technical Publications Zenith Electronics Corporation P.O. Box 24
2、0007 Huntsville, Alabama 35824 Copyright June 2001 by Zenith Electronics Corporation Made/Printed in the U.S.A. Model Series: CONTENTS DVD5201 DVD5591 RadioFans.CN 收音机爱 好者资料库 VR166 - 923-03461 2 DVD2 - SAFETY PRODUCT SAFETY GUIDELINES IMPORTANT SAFETY NOTICE This manual was prepared for use only by
3、properly trained audio-visual service technicians. When servicing this product, under no circumstances should the original design be modified or altered without permission from Zenith Electronics Corporation. All components should be replaced only with types identical to those in the original circui
4、t and their physical location, wiring and lead dress must conform to original layout upon completion of repairs. Special components are also used to prevent x-radiation, shock and fire hazard. These components are indicated by the letter “x” included in their component designators and are required t
5、o maintain safe performance. No deviations are allowed without prior approval by Zenith Electronics Corporation. Circuit diagrams may occasionally differ from the actual circuit used. This way, implementation of the latest safety and performance improvement changes into the set is not delayed until
6、the new service literature is printed. CAUTION: Do not attempt to modify this product in any way. Never perform customized installations without manufacturers approval. Unauthorized modifications will not only void the warranty, but may lead to property damage or user injury. Service work should be
7、performed only after you are thoroughly familiar with these safety checks and servicing guidelines. GRAPHIC SYMBOLS The exclamation point within an equilateral triangle is intended to alert the service personnel to important safety information in the service literature. The lightning flash with arro
8、whead symbol within an equilateral triangle is intended to alert the service personnel to the presence of noninsulated “dangerous voltage” that may be of sufficient magnitude to constitute a risk of electric shock. The pictorial representation of a fuse and its rating within an equilateral triangle
9、is intended to convey to the service personnel the following fuse replacement caution notice: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ALL FUSES WITH THE SAME TYPE AND RATING AS MARKED NEAR EACH FUSE. SERVICE INFORMATION While servicing, use an isolation transformer for protec
10、tion from AC line shock. After the original service problem has been corrected, make a check of the following: FIRE AND SHOCK HAZARD 1. Be sure that all components are positioned to avoid a possibility of adjacent component shorts. This is especially important on items trans- ported to and from the
11、repair shop. 2. Verify that all protective devices such as insulators, barriers, covers, shields, strain reliefs, power supply cords, and other hardware have been reinstalled per the original design. Be sure that the safety purpose of the polarized line plug has not been defeated. 3. Soldering must
12、be inspected to discover possible cold solder joints, solder splashes, or sharp solder points. Be certain to remove all loose foreign particles. 4. Check for physical evidence of damage or deterioration to parts and compo- nents, for frayed leads or damaged insulation (including the AC cord), and re
13、place if necessary. 5. No lead or component should touch a receiving tube or a resistor rated at 1 watt or more. Lead tension around protruding metal surfaces must be avoided. 6. After reassembly of the set, always perform an AC leakage test on all exposed metallic parts of the cabinet (the channel
14、selector knobs, antenna terminals, handle and screws) to be sure that set is safe to operate without danger of electrical shock. DO NOT USE A LINE ISOLATION TRANSFORMER DURING THIS TEST. Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following manner: Connect a 1500 ohm, 10
15、 watt resistor, paralleled by a .15 mfd 150V AC type capacitor between a known good earth ground water pipe, conduit, etc.) and the exposed metallic parts, one at a time. Measure the AC voltage across the combination of 1500 ohm resistor and .15 mfd capacitor. Reverse the AC plug by using a non-pola
16、rized adaptor and repeat AC voltage measurements for each exposed metallic part. Voltage measured must not exceed 0.75 volts RMS. This corresponds to 0.5 milliamp AC. Any value exceeding this limit constitutes a potential shock hazard and must be corrected immediately. X-RADIATION 1.Be sure procedur
17、es and instructions to all service personnel cover the subject of x-radiation. The only potential source of x-rays in current TV receivers is the picture tube. However, this tube does not emit x-rays when the HV is at the factory-specified level. The proper value is given in the applicable schematic
18、. Operation at higher voltages may cause a failure of the picture tube or high-voltage supply and, under certain circumstances may produce radiation in excess of desirable levels. 2.Only factory-specified CRT anode connectors must be used. 3.It is essential that the service personnel have available
19、an accurate and reliable high-voltage meter. 4.When the high-voltage circuitry is operating properly, there is no possibility of an x-radiation problem. Every time a color chassis is serviced, the brightness should be run up and down while monitoring the high voltage with a meter, to be certain that
20、 the high voltage does not exceed the specified value and that it is regulating correctly. 5.When troubleshooting and making test measurements in a product with a problem of excessively high voltage, avoid being unnecessarily close to the picture tube and the high voltage power supply. Do not operat
21、e the product longer than necessary to locate the cause of excessive voltage. 6.Refer to HV, B+, and shutdown adjustment procedures described in the appropriate schematics and diagrams (where used). IMPLOSION 1.All direct view picture tubes are equipped with an integral implosion protection system;
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Zenith-DVD5201-cd-sm 电路图 维修手册 Zenith DVD5201 cd sm 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf