FLUKE PM6669__omeng0000 电路图.pdf
《FLUKE PM6669__omeng0000 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE PM6669__omeng0000 电路图.pdf(48页珍藏版)》请在收音机爱好者资料库上搜索。
1、Universal Frequency Counter PM6669 Operators Manual RadioFans.CN 收音机爱 好者资料库 CONTENTS SAFETY.2 Introduction .2 PRODUCT PRESENTATION .3 General .3 Rear View.3 Front View.4 INSTALLATION .5 Unpacking.5 Voltage-Range Selection .5 Grounding .5 Connecting External Reference.6 Installing Options .6 Calibrat
2、ing the MTCXO.6 OPERATING INSTRUCTIONS.8 Using the Frequency Counter.8 Battery Unit .20 Error Codes.20 GPIB-INTERFACE OPERATION.21 Introduction .21 What Can I Do Using the Bus?.21 Connecting the Controller.22 Giving the Counter an Address.22 Checking the Communication.22 Two Ways of Programming.23 S
3、yntax .23 Selecting Output Separator.24 How to Select Function .24 Selecting Measuring-Time.24 Selecting Triggering.25 Totalize Start/Stop .25 Free-Run/Triggered.25 Service Request.26 Status Byte.26 Output Mode.27 Bus Learn.30 Programming Data Out .30 What Happens When I Switch to Local?.30 Summary
4、of Bus Commands.31 Programming Examples.32 SPECIFICATIONS .35 Measuring Functions.35 Definitions.36 Input specifications.36 General Information.37 Auxiliary Functions.38 Optional Accessories.38 Ordering Information .40 APPENDIX 1.41 Checking the Sensitivity of Counters .41 INDEX .43 4822 872 20021 5
5、/12-April-1995 CONTENTSPage: 1 PM 6669 - OPERATORS MANUAL RadioFans.CN 收音机爱 好者资料库 SAFETY Introduction Read this page carefully before you install and use the PM 6669 Frequency Counter. This Frequency Counter has been designed and tested in accordance with IEC publication 1010-1, and CSA 22.2 No.231,
6、 and has been supplied in a safe condition. The user of this instrument must have the required knowledge of PM 6669. This knowledge can be gained by thoroughly studying this manual. Safety Precautions Use generally-accepted safety procedures, in addition to the safety precautions stated in this manu
7、al, to ensure per- sonal safety and safe operation of the Frequency Counter. Caution Set the intermediate frequency as the constant A0. Select FREQ A-A0 and measure the frequency of the local oscillator, and the display will show the received frequency. The frequency on Input-A is multiplied by 60 a
8、nd dis- played as Revolutions Per Minute. Range:6 RPM to 720 000 000 RPM. When you select SINGLE, the Frequency Counter measures one period, the range is: 100 ns to 200 000 000 s (about 6 years and four months!). When you select 0.2, 1, and 10 s Measuring-time, the Frequency Counter divides the inpu
9、t frequency by 10 and measures the average period for the No. of cy- cles in that time. Range: 8 ns to 1 s. Use SINGLE when the input frequency is low. This shortens the measuring time considerably since one cycle is measured instead of 10. The Frequency Counter counts the total number of pulses fed
10、 to Input-A. You start and stop the totalizing with the TOTALIZE START/STOP key (RESET/LO- CAL). If you keep this key depressed for more than one second, the total sum will be reset. Range: 0 to 1*1015 pulses k on the display indicates kilo-pulses (1000) and M in- dicates Mega-pulses(1 000 000). The
11、 Measuring-time indicator is switched off in TOT A MAN. OPERATING INSTRUCTIONSPage: 11 PM 6669 - OPERATORS MANUAL CONTROLOPERATING THE CONTROL DISPLAYGPIB-CODE Move function cursor to WIDTH A WIDTH A or PWIDTH A MEAS TIME is operated in the same way as the func-tions control, see page 8. MTIME where
12、 is the time in seconds. Range: 10 ms to 10 s. 0 = Single Move the measuring- time cursor to SINGLE MTIME 0 Move the measuring- time cursor to 0.2 s MTIME 0.2 Move the measuring- time cursor to 1 s MTIME 1 Move the measuring - time cursor to 10 s MTIME 10 FUNCTION TRIGGER LEVEL A HOLD DISPLMEASURING
13、 TIME 10s1s0.2sSINGLE REF EXT A WIDTH A TOT A PER A RPM A-A0 FREQ A/A0 FREQ B FREQ A FREQ FUNCTION AUTO ms 0. TIME MEAS TIME MEAS TRIGGER LEVEL A HOLD DISPLMEASURING TIME 10s1s0.2sSINGLE REF EXT A WIDTH A TOT A PER A RPM A-A0 FREQ A/A0 FREQ B FREQ A FREQ FUNCTION AUTO kHz TIME MEAS TRIGGER LEVEL A H
14、OLD DISPLMEASURING TIME 10s1s0.2sSINGLE REF EXT A WIDTH A TOT A PER A RPM A-A0 FREQ A/A0 FREQ B FREQ A FREQ FUNCTION AUTO kHz TIME MEAS TRIGGER LEVEL A HOLD DISPLMEASURING TIME 10s1s0.2sSINGLE REF EXT A WIDTH A TOT A PER A RPM A-A0 FREQ A/A0 FREQ B FREQ A FREQ FUNCTION AUTO kHz TIME MEAS TRIGGER LEV
15、EL A HOLD DISPLMEASURING TIME 10s1s0.2sSINGLE REF EXT A WIDTH A TOT A PER A RPM A-A0 FREQ A/A0 FREQ B FREQ A FREQ FUNCTION AUTO kHz Page: 12OPERATING INSTRUCTIONS PM 6669 - OPERATORS MANUAL FUNCTION AND RANGEHINTS AND COMMENTS The counter measures the positive pulse width of the signal on Input-A. R
16、ange: 100 ns to 200 000 000 s. If you are interested in the negative pulse width instead; first measure the period and make a note of the result, then measure the pulse width and substract it from the period reading. The set Measuring-time controls the time during which the main gate is opened, allo
17、wing pulses to en- ter the counting logic. A longer Measuring-time gives higher resolution readouts with more digits displayed. The time the gate is open is not exactly the preset Measuring-time, because the Frequency Counter syn- chronizes the measurement with the input signal in or- der to measure
18、 complete periods. If the period of the input signal is longer than the set Measuring-time, the main gate does not close again until the period is completed. If you wish to do one measurement instead of repetitive measurements, see DISPL HOLD. For PER A and WIDTH exactly one period or one time inter
19、val is measured. The minimum result possi- ble is 100 ns. The display time will be 100 ms. When set to SINGLE, FREQ A and, RPM A, the Measuring-time is one cycle of the input signal or 3 ms, whichever is longest. When set to SINGLE and FREQ B, the Measuring-time is 3 ms. The input frequency is limit
20、ed to 16 MHz for FREQ A, PER A, and RPM A. If external reference is used, the EXT REF indicator will not be switched-on until after the first measurement. A Frequency-A measurement will result in 6-7 digits on the display. A Frequency-A measurement will result in 7-8 digits on the display. A Frequen